The electrochemical oxidation behavior of hydrochlorothiazide (HCT) on a glassy carbon as a working electrode was investigated in Britton-Robinson (B-R) buffer pH 3, by using anodic stripping voltammetry (ASV) and cyclic voltammetry (CV). This drug gave a well-defined voltammetric oxidation peak at + 1200 mV versus an Ag/AgCl reference electrode. The electrochemical oxidation process was shown to be irreversible and diffusion controlled, with adsorption characterized over the entire pH range. The optimized conditions, such as accumulation time and potential, scan rate, frequency, pulse amplitude, varying of working electrodes, and instrumental parameters were studied. The calibration graph for HCT was obtained from 4 × 10-6 to 4 × 10-5 M (correlation coefficient = 0.997) using the developed electroanalytical method (ASV). The detection limit of this drug was 4.3 × 10-9 M. ASV and CV techniques with adequate precision and accuracy have been developed and applied for direct determination of HCT in commercial tablets without separation or extraction procedures and biological fluids such as urine and plasma.
A validated simple, rapid, sensitive and specific square-wave voltammetric technique is described for the determination of acebutolol (AC) following its accumulation onto a hanging mercury drop electrode in a Britton-Robinson universal buffer of pH 7.5. The optimal procedural conditions were: accumulation potential Eacc = - 0.8 V versus Ag/AgCl/KCl, accumulation duration tacc = 30 s, pulse-amplitude = 70 mV, scan rate = 100 mV/s, frequency = 30 Hz, surface area of the working electrode = 0.6 mm2 and the convection rate = 2000 rpm. Under these optimized conditions, the adsorptive stripping voltammetry (AdSV) peak current was proportional over the concentration range 5 × 10-7 - 6 × 10-6 M (r = 0.999). Recoveries for acebutolol from human plasma and urine were in the range 97-103% and 96-104% respectively. The method proved to be precise (intra-day precision expressed as %RSD in human plasma ranged from 2.9 - 3.2% and inter-day precision expressed as %RSD ranged from 3.4 - 3.8%) and accurate (intra-day accuracies expressed as % error in human urine ranged from -3.3 - 2.8% and inter-day accuracies ranged from -3.3 - 1.7%). The limit of quantitation (LOQ) and limit of detection (LOD) for acebutolol were 1.7 × 10-7 and 5 × 10-7 M, respectively. Possible interferences by substances usually present in the pharmaceutical formulations were investigated with a mean recovery of 101.6 ± 0.64%. Results of the developed square-wave adsorptive stripping voltammetry (SW-AdSV) method were comparable with those obtained by reference analytical method.
26 April 2014 in Russian Journal of Electrochemistry
In this study a reduction square wave voltammetric method was developed and validated for the direct determination of ciprofloxacin (CIP) in pharmaceutical formulation and biological fluid using hanging mercury dropping electrode (HMDE) surface. Best results were obtained for the quantitative determination of CIP in 0.02 M Britton-Robinson buffer at pH 2.5 and at a potential of −1300 mV vs. Ag/AgCl reference electrode. Various experimental and instrumental parameters affecting the peak current and potential of CIP electrochemical reduction were investigated and optimized. The monitored peak current was directly proportional to the concentration of CIP, where it exhibited a linear response in the range 3.0 × 10−7–2 × 10−6 M (r = 0.99). The accuracy of the proposed method was concluded based on the value of mean recovery of 98 ± 0.72 % with RSD of 0.181 % at a detection limit of 7 × 10−9 M. Possible interferences by various substances usually present in pharmaceutical formulations have been also evaluated. After validating the proposed method, the applicability of this voltammetric method was demonstrated by estimating CIP in its pharmaceutical formulation and spiked human urine, where values of mean recoveries of 97 ± 1.0% and 108.0 ± 2.0% were obtained, respectively.
Background: Atorvastatin calcium belongs to a group of drugs known as statins. It is commonly used to treat a heart disease, so it is used to lower or reduce the fats and bad cholesterol in blood. It has also been used to increase the good cholesterol in blood. Atorvastatin calcium content is commercially known as "Lipitor" tablet. It is available in local pharmacies at different concentrations; 10, 20 and 40mg. Atorvastatin calcium has been previously determined by several analytical techniques such as chromatographic methods, spectrophotometry and electrochemical methods. Methods: Atorvastatin calcium drug was determined in pharmaceuticals using voltammetric techniques, HPLC and UV Vis onto surface of ultra-trace graphite (UT) working electrode. It was also analysed by voltammetric techniques in biological fluids such as plasma and urine. Results: Some analytical parameters were evaluated such as buffer solutions, pH, accumulation time and potential, frequency, scan rate, amplitude voltage step and rate of stirring, using UT electrode vs. Ag/AgCl reference electrode and Pt auxiliary electrode. There are some parameters such as recovery, reproducibility, stability, calibration curve, detection limit, quantification limit and interference, which were also studied. Analytical applications for ATOR were carried out using pharmaceuticals that contained 10, 20 and 40 mg ATOR; and biological samples. Spectrophotometric and HPLC procedures were used for analytical applications to compare their results with anodic stripping voltammetry in terms of accuracy and precision. Conclusion: The developed adsorptive anodic stripping voltammetric method was applied for the determination of ATOR using phosphate buffer at pH3 ATOR at phosphate buffer pH3, 30 s tacc, -0.6 V Eacc, 50 mV amplitude and 3000 rpm in its pharmaceuticals and biological samples. In this research, the determination of ATOR confirmed a high sensitivity of adsorptive anodic stripping voltammetry method comparing other electrochemical methods. The LOD and LOQ also confirmed the sensitivity of the adsorptive anodic stripping voltammetric method. HPLC and UV Vis spectrophotometric methods were used for the comparison of results with adsorptive anodic stripping voltammetry concerning analytical application of ATOR tablets. There are many published articles for the determination of ATOR, but they were lower than adsorptive anodic stripping voltammetry in terms of sensitivity and an ultra trace graphite working electrode was used in this research as an additional advantage.