Mohamed Hefnawy

Prof. Mohamed Hefnawy

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2023 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
RHRafaqat Hussain
Rafaqat Hussain
Wajid RehmanWajid Rehman
Wajid Rehman
SKShoaib Khan
Shoaib Khan
AMAneela Maalik
Aneela Maalik
MHMohamed Hefnawy
Mohamed Hefnawy
LRLiaqat Rasheed
Liaqat Rasheed
A new series of thiazole derivatives (4a-p) incorporating imidazopyridine moiety was synthesized and assessed for their in vitro potential α-glucosidase potency using acarbose as a reference drug. The obtained results suggested that compounds 4a (docking score = −13.45), 4g (docking score = −12.87), 4o (docking score = −12.15), and 4p (docking score = −11.25) remarkably showed superior activity against the targeted α-glucosidase enzyme, with IC50 values of 5.57 ± 3.45, 8.85 ± 2.18, 7.16 ± 1.40, and 10.48 ± 2.20, respectively. Upon further investigation of the binding mode of the interactions by the most active scaffolds with the α-glucosidase active sites, the docking analysis was accomplished in order to explore the active cavity of the α-glucosidase enzyme. The interpretation of the results showed clearly that scaffolds 4a and 4o emerged as the most potent α-glucosidase inhibitors, with promising excellent binding interactions with the active site of the α-glucosidase enzyme. Furthermore, utilizing a variety of spectroscopic methods, such as 1H-NMR, 13C-NMR, and HREI-MS, the precise structures of the synthesized scaffolds were determined.

21 February 2012 in BMC Chemistry
Verified
Journal Article
Open access
PDF file
AAAli Alghamdi
Ali Alghamdi
MHMohamed Hefnawy
Mohamed Hefnawy
AAAbdulrahman A Al-Majed
Abdulrahman A Al-Majed
FBFatallah F Belal
Fatallah F Belal
A validated simple, rapid, sensitive and specific square-wave voltammetric technique is described for the determination of acebutolol (AC) following its accumulation onto a hanging mercury drop electrode in a Britton-Robinson universal buffer of pH 7.5. The optimal procedural conditions were: accumulation potential Eacc = - 0.8 V versus Ag/AgCl/KCl, accumulation duration tacc = 30 s, pulse-amplitude = 70 mV, scan rate = 100 mV/s, frequency = 30 Hz, surface area of the working electrode = 0.6 mm2 and the convection rate = 2000 rpm. Under these optimized conditions, the adsorptive stripping voltammetry (AdSV) peak current was proportional over the concentration range 5 × 10-7 - 6 × 10-6 M (r = 0.999). Recoveries for acebutolol from human plasma and urine were in the range 97-103% and 96-104% respectively. The method proved to be precise (intra-day precision expressed as %RSD in human plasma ranged from 2.9 - 3.2% and inter-day precision expressed as %RSD ranged from 3.4 - 3.8%) and accurate (intra-day accuracies expressed as % error in human urine ranged from -3.3 - 2.8% and inter-day accuracies ranged from -3.3 - 1.7%). The limit of quantitation (LOQ) and limit of detection (LOD) for acebutolol were 1.7 × 10-7 and 5 × 10-7 M, respectively. Possible interferences by substances usually present in the pharmaceutical formulations were investigated with a mean recovery of 101.6 ± 0.64%. Results of the developed square-wave adsorptive stripping voltammetry (SW-AdSV) method were comparable with those obtained by reference analytical method.

1 October 2009 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
MHMohamed Hefnawy
Mohamed Hefnawy
Mohamed A. Al-OmarMohamed A. Al-Omar
Mohamed A. Al-Omar
SJSaeed Julkhuf
Saeed Julkhuf

25 January 2023 in Journal of Chromatography A
Verified
Journal Article
Closed access
MHMohamed Hefnawy
Mohamed Hefnawy
MEManal El-Gendy
Manal El-Gendy
HAHuda Al-Salem
Huda Al-Salem
HMHanin Marenga
Hanin Marenga
AEAdel El-Azab
Adel El-Azab
AHAbdullah Hefnawy
Abdullah Hefnawy

12 November 2009 in Journal of Liquid Chromatography & Related Technologies
Verified
Journal Article
Closed access
MHMohamed Hefnawy
Mohamed Hefnawy
MSMaha Sultan
Maha Sultan
HAHaya Al-Johar
Haya Al-Johar
A simple, accurate, precise, and sensitive capillary electrophoresis (CE) technique coupled to a diode array detector (DAD) has been developed for the separation and simultaneous determination of amlodipine (AM) and atorvastatin (AT) from their combination formulations. The proposed method utilized fused silica capillary (50 cm × 75 µm ID) and background electrolyte (BGE) composed of phosphate buffer (pH 6.5, 25 mM)-methanol, (80:20, v/v). The separation was achieved at 15 KV applied voltage and 25°C. Losartan was chosen as the internal standard to guarantee a high level of quantitative performance. The two drugs were subjected to thermal, photolytic, hydrolytic, and oxidative stress conditions and the stressed samples were analyzed by the proposed method. The method has shown adequate separation for AM and AT from its main degradation products (UK-55-410) & (PD 0162910-00), respectively, which demonstrated the specificity of the assay. The described method was linear over the range of 1 – 50 µg/mL (r = 0.9998) for both drugs (2.4 × 10−6 − 1.2 × 10−4 M for AM and 1.8 × 10−6 −8.6 × 10−5 M for AT). Intra- and inter-day RSD (n = 6) was ≤2.2%. The limits of detection for AM and AT were 0.5 µg/mL. The percentage recoveries (n = 6) of the two drugs from their tablet formulations were 99.97 ± 1.84 and 100.96 ± 1.12, respectively. Degradation products produced as a result of stress studies did not interfere with the detection of AM and AT and the assay can thus be considered stability indicating.

1 January 2007 in Chemical and Pharmaceutical Bulletin
Verified
Journal Article
Open access
PDF file
MHMohamed Hefnawy
Mohamed Hefnawy
MSMaha Abd-Alrahman Sultan
Maha Abd-Alrahman Sultan
MAMona Mohamed Al-Shehri
Mona Mohamed Al-Shehri
A sensitive, enantioselective, high-performance liquid chromatographic (HPLC) method was developed and validated to determine S-(−)- and R-(+)-bisoprolol in human plasma. Baseline resolution was achieved using the teicoplanin macrocyclic antibiotic chiral stationary phase (CSP) known as Chirobiotic T with a polar ionic mobile phase (PIM) consisting of methanol–glacial acetic acid–triethylamine (100 : 0.02 : 0.025, v/v/v) at a flow rate of 1.5 ml/min and fluorescence detection set at 275 nm for excitation and 305 nm for emission. All analyses with S-(−)-atenolol as the internal standard were conducted at ambient temperature. The assay involved the use of a solid-phase extraction procedure for human plasma samples prior to HPLC analysis. The C18 cartridge gave good recovery rates for both enantiomers without any interference. The method was validated over the range of 20—200 ng/ml for each enantiomer concentration. Recovery rates for S-(−)- and R-(+)-bisoprolol enantiomers were in the range of 95—102%. The method proved to be precise (within-run precision expressed as % RSD ranged from 1.0—6.2% and between-run precision ranged from 0.9—6.7%) and accurate (within-run accuracies expressed as percentage error ranged from 0.2—4.8% and between-run accuracies ranged from 0.3—1.7%). The limit of quantitation and limit of detection for each enantiomer in human plasma were 20 and 5 ng/ml, respectively.