Piotr Bielówka

Piotr Bielówka

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
ADArkadiusz Piotr Dąbrowski
Arkadiusz Piotr Dąbrowski
WNWitold Nawrot
Witold Nawrot
MCMateusz Czok
Mateusz Czok
MBMichał Babij
Michał Babij
PBPiotr Bielówka
Piotr Bielówka
KMKarol Malecha
Karol Malecha
The Low Temperature Cofired Ceramic (LTCC) technology has proven to be highly suitable for 3D microstructures manufacturing in electronic devices due to its excellent electrical and mechanical properties. In this paper, a novel idea of implementing the LTCC structures into high-energy particle detectors technology is proposed. It can be applied in High Energy Physics (HEP) laboratories, where such sophisticated sensors are constantly exposed to particles of the TeV energy range for many years. The most advanced applications of the concept are based on dedicated gas amplifier systems coupled with readout microstructures. Typically, the readout microstructures are made in the Printed Circuit Boards (PCB) technology and processed in a sophisticated and patent-protected way. This article presents the manufacturing process and parameters of the novel microstructures made in the LTCC technology. The structures were implemented into the high-energy particle detector, and the first results are presented.

14 November 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
PBPiotr Bielówka
Piotr Bielówka
MBMichał Babij
Michał Babij
ADArkadiusz Dąbrowski
Arkadiusz Dąbrowski
KMKarol Malecha
Karol Malecha

26 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MBMichał Babij
Michał Babij
PBPiotr Bielówka
Piotr Bielówka
SGSzymon Gburek
Szymon Gburek
KMKarol Malecha
Karol Malecha
The Gas Electron Multiplier (GEM) was introduced by Fabio Sauli in 1997. This technology is broadly used in current and planned High-Energy Physics (HEP) experiments. One of the key components of these detectors is a readout board, which collects charges amplified by GEM foils and transfers them to readout electronics. The commonly used Cartesian XY readout boards are manufactured from the same type of polyamide film used to produce the GEM foils. The manufacturing process utilizes a deep polyimide etching, similar to the Micro Chemical Vias (MCV) etching process, which is protected by patent. The material prepared in this way is glued onto a rigid substrate and mounted in a detector. The production process was developed at CERN, and the technology has been commercialized to a small extent. Consequently, only a few research centers have the ability to make dedicated readout strips readouts. GEM detectors are characterized by a segmented structure that allows the separation of an electron-multiplying structure from a readout. This feature enables the implementation of a new type of charge reading system without the need to interfere with the GEM foil system. A new approach is proposed to simplify production and reduce the costs of GEM detector readout boards. It is based on the concept of segmental readout structures that are manufactured in standard Printed Circuit Board (PCB) technology. The interconnectors and mountings are located on the back of the bottom, so it is possible to place the readout electronics behind the readout plate. The boards are designed in such a way that they can be panelized into a readout with a more extensive active area. The margin between PCBs is minimalized to approximately 200 µm, which is less than 1% of the 70 × 70 mm2 board area, so the active area is as big as possible. Therefore, this solution gives us the ability to further increase the size of a readout by adding additional segments, which reduces the cost of scaling up the detector size. A few research groups have suggested similar solutions that utilize PCB technology, but currently, only detectors with 1D zigzag readouts have been validated and used. The measurement results of other 2D (XY) redouts using PCB technology have not been presented. The measurements shown and discussed in this paper validated the proposed technology. X-ray radiographs were obtained, validating the ability to use this technology to manufacture readout boards for GEM detectors. In opposition to state-of-the-art readouts, the proposed solution can be manufactured by any PCB manufacturer without using MCV-patented technology. This gives the users flexibility in designing and ordering low-cost custom readouts.