Mahmoud Abdelfatah Mohamed

Dr. Mahmoud Abdelfatah Mohamed

Quality Control, Hikma Pharmaceuticals (United Kingdom), London, City of London, UK
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2024 in Reviews in Analytical Chemistry
Verified
Journal Article
Open access
PDF file
HNHossam Nassef
Hossam Nassef
Hoda A. AhmedHoda A. Ahmed
Hoda A. Ahmed
ABAli Bashal
Ali Bashal
MEMohamed Elatawy
Mohamed Elatawy
TATahani Y. A. Alanazi
Tahani Y. A. Alanazi
MMMahmoud Abdelfatah Mohamed
Mahmoud Abdelfatah Mohamed
A green analytical chemistry study attempts to generate environmentally friendly alternatives to dangerous compounds while reducing waste output. The study thoroughly analyzed eight green tools to determine their greenness. Given its importance in treating hallucinations and delusions produced by Parkinson’s disease psychosis, it is critical to have a reliable and precise method for identifying pimavanserin (PVS) in both pure form and pharmaceutical formulations. The current study used a straightforward approach to forced degradation experiments to establish a novel reversed-phase high-performance liquid chromatography method for evaluating stability. The method was executed on the Agilent Zorbax Eclipse Plus C18 column (100 × 4.6 mm, 3.5 μm particle size) with ultraviolet detection at 226 nm. The Box–Behnken design is the ultimate solution for identifying optimal chromatographic conditions in a timely and efficient manner, with minimal trials required. The study investigated the impact of three factors: acetonitrile ratio, column oven temperature, and flow rate on various responses, namely, retention time, tailing factor, and theoretical plates. Desirability and overlay plots were utilized to forecast the best mobile phase containing a buffer solution: acetonitrile: tetrahydrofuran in a ratio of (65: 20: 15, v/v/v), which proved highly effective in the experiments. Linearity was conducted for PVS in the 3–50 µg·mL −1 range with an R 2 coefficient of determination of 0.9997. PVS had detection and quantification limits of 1.1 and 3.5 µg·mL −1 , respectively, indicating a highly significant correlation between the variables studied. PVS’s recovery percentage was determined to be 101.30%. We also used the Six Sigma lean technique to ensure precision and productivity. PVS was tested for acid, base, oxidative hydrolysis, photodegradation, and heat, as per International Council for Harmonisation guidelines. The highest degradation was obtained from oxidative hydrolysis and thermal degradation.

7 January 2024 in Green Chemistry Letters and Reviews
Verified
Journal Article
Open access
HNHossam M. Nassef
Hossam M. Nassef
HAHoda A. Ahmed
Hoda A. Ahmed
MEMohamed Elatawy
Mohamed Elatawy
TATahani Y. A. Alanazi
Tahani Y. A. Alanazi
MMMahmoud Abdelfatah Mohamed
Mahmoud Abdelfatah Mohamed

13 October 2023 in Sustainable Chemistry and Pharmacy
Verified
Journal Article
Closed access
SMSamar M. Mahgoub
Samar M. Mahgoub
MMM. Ramadan Mahmoud
M. Ramadan Mahmoud
ABAmmena Y. Binsaleh
Ammena Y. Binsaleh
MAManal A. Almalki
Manal A. Almalki
MMMahmoud Abdelfatah Mohamed
Mahmoud Abdelfatah Mohamed
HNHossam F. Nassar
Hossam F. Nassar

7 January 2022 in Journal of AOAC INTERNATIONAL
Verified
Journal Article
Closed access
MMMahmoud Abdelfatah Mohamed
Mahmoud Abdelfatah Mohamed
Background: A combination of paracetamol, pseudoephedrine, chlorpheniramine, and sodium benzoate in (Cold–Flu) 1,2,3 Syrup dosage form is specified for the treatment of common cold and flu symptoms. Objective: The functional role of this study is to develop a novel, reliable, and selective stability-indicating reversed-phase ultra-performance liquid chromatography (RP-UPLC) method for simultaneous identification of a quaternary mixture of paracetamol, pseudoephedrine, chlorpheniramine, and sodium benzoate in (Cold–Flu) 1,2,3 Syrup dosage form. Method: The specific method is accomplished using an Acquity UPLC HSS T3 C18 column (2.1 mm × 100 mm), 1.8 µm particle size with pore size 100 Å, utilizing a mixture of purified water–methanol–trifluoroacetic acid (72.5:27.5:1.5, v/v) as the mobile phase at a flow rate of 0.3 mL/min. The column void volume is 1.15 min. UPLC detection is adjusted at 205 nm using a photodiode array detector. Results: Calibration curves are obtained in the linearity ranges: 25–500 µg/mL for paracetamol, 10–50 µg/mL for pseudoephedrine, 0.5–5 µg/mL for chlorpheniramine, and 3–30 µg/mL for sodium benzoate with a correlation coefficient > 0.9992. The mean recovery of the developed method is tested and shows good recovery results between 99–101%; selectivity and forced degradation studies are investigated as per the International Council for Harmonisation Guidelines and no interference is detected due to degradation peaks. Conclusion: The proposed stability-indicating UPLC method for simultaneous determination of the three drugs, paracetamol, pseudoephedrine, and chlorpheniramine, with a preservative sodium benzoate in (Cold–Flu) 1,2,3 Syrup dosage form is successfully accomplished, developed, and validated, and can be easily used in the analysis of drugs in pure or dosage form. Highlights: The novelty of the current research work lies in the development of the UPLC method for simultaneous determination of a quaternary mixture of paracetamol, pseudoephedrine, chlorpheniramine, and sodium benzoate in (Cold–Flu) 1,2,3 Syrup dosage form.

18 October 2024 in Talanta Open
Verified
Journal Article
Open access
EAEman A. Assirey
Eman A. Assirey
NKNoha S. Katamesh
Noha S. Katamesh
MMMahmoud Abdelfatah Mohamed
Mahmoud Abdelfatah Mohamed

10 October 2023 in BMC Chemistry
Verified
Journal Article
Open access
PDF file
NANada S. Al-Kadhi
Nada S. Al-Kadhi
MMMahmoud Abdelfatah Mohamed
Mahmoud Abdelfatah Mohamed
Hoda A. AhmedHoda A. Ahmed
Hoda A. Ahmed
HNHossam Nassar
Hossam Nassar
Economical, highly robust, selective, precise, and eco-friendly RP-UPLC and spectrophotometric methods were developed and validated for the concurrent estimation of selected pharmaceutical drugs represented in ceftazidime (CFZ) and pyridine (PYD) in their solutions using Agilent Zorbax SB-C18 RRHD (50 × 2.1 mm, 1.8 μm) column at flow rate 0.3 mL/min with wavelength 254 nm. Box-Behnken design (BBD) established Response surface methodology (RSM) to achieve the optimum chromatographic condition with minimal trials conducted. Three independent variables specifically acetonitrile ratio 60–70%, pH 3–7, and temperature 25–35 °C were implemented to evaluate the influences of these variables on the responses as resolution and retention time. Desirability and overlay plots were carried out to adjust the optimal condition that achieved the shortest retention time of less than 2 min and desired resolution of more than 1.5 using a mobile phase consisting of acetonitrile: purified water (70:30, v/v) at pH 5.0 adjusted by 0.1% orthophosphoric acid with the column oven temperature 30 °C and column void volume 0.46 mL. Mean centering of ratio spectra (MCR) and ratio subtraction (RS) methods were effectively applied to resolve drugs' spectral superposition at 220 nm, 255.4 nm, 260.3 nm, and 254.6 nm for CFZ and PYD, respectively. Linearity range was accomplished for UPLC, MCR, and RS methods over the concentration range of 2–100, 1–50,3–30 and 5–30 µg/mL for CFZ and PYD, respectively with correlation coefficient > 0.999 and good recovery results within 98–102%. Six Sigma methodology was achieved using the process capability index (Cpk) to compare the suggested and USP methods showing that both are highly capable with Cpk > 1.33. The proposed method was successfully validated depending on ICH guidelines and ANOVA results and applied for the accelerated stability study. Graphical Abstract