Introduction: Wound healing is a delicate and complex process influenced by many factors. The treatment of skin wounds commonly involves the use of wound dressings, which remain a routine approach. An ideal dressing can provide protection and a suitable environment for wound surfaces by maintaining moisture and exhibiting good biocompatibility, mechanical strength, and antibacterial properties to promote healing and prevent infection.Methods: We encapsulated tick-derived antibacterial polypeptides (Os) as a model drug within a methylacrylyl gelatin (GelMA) hydrogel containing MXene nanoparticles. The prepared composite hydrogels were evaluated for their wound dressing potential by analyzing surface morphology, mechanical properties, swelling behavior, degradation properties, antibacterial activity, and cytocompatibility.Results: The results demonstrated excellent mechanical strength, swelling performance, degradation behavior, and antibacterial activity of the prepared composite hydrogels, effectively promoting cell growth, adhesion, and expression of antibacterial peptide activity. A full-thickness rat wound model then observed the wound healing process and surface interactions between the composite hydrogels and wounds. The composite hydrogel significantly accelerated wound closure, reduced inflammation, and sped epithelial formation and maturation.Discussion: Incorporating antibacterial peptides into GelMA provides a feasible strategy for developing excellent antibacterial wound dressings capable of tissue repair. In conclusion, this study presents a GelMA-based approach for designing antibacterial dressings with strong tissue regenerative ability.
Resistance spot welding was performed to join a 2 mm thick TA2 titanium plate and Q235 steel plate using nickel foil with thicknesses of 0.02 mm, 0.04 mm, and 0.06 mm as interlayers. The microstructure of the nugget zone and the interface region of the joint were systematically observed and analyzed, and the tensile shear-bearing capacity of the joint was evaluated. As the welding current increased, the tensile shear load of the joint exhibited a trend of initially increasing and subsequently decreasing. When the welding current was 8 kA, the tensile shear load of the joints with an interlayer of 0.04 mm thickness reached a maximum value of 8.02 kN. The results indicate that employing a reduced welding current can effectively prevent the mixing of nuggets on both sides of the titanium and steel interface. This ensures that the intermetallic compounds formed in the interface region are confined to the Ti-Ni series, which is crucial for enhancing the tensile shear load of the joint.
Background Most displaced femoral neck fractures can achieve satisfactory anatomical reduction by closed reduction, but there are still some that cannot reset satisfactorily after closed reduction, and open reduction are required. Such fractures that cannot be repositioned successfully by closed reduction are called irreducible displaced femoral neck fractures in this study. The objective of our study was to evaluate the efficacy of direct anterior incision with the Femoral Neck System in the treatment of irreducible displaced femoral fractures.Methods A total of 16 young and middle-aged patients with irreducible displaced femoral neck fractures involving Garden type III and IV were treated using Femoral Neck System fixation by open reduction through Direct Anterior Approach between January 2020 to September 2021. Functional outcomes and postoperative complications were assessed during follow-up. Clinical outcomes were evaluated by the Hip Harris score. The postoperative reduction was evaluated by the Garden Index. Observe postoperative complications.Results All patients were followed up with a mean follow-up time of 21.1(12–30) months, and according to radiological results, all patients achieved fracture healing, with a mean healing time of 4.25 months. All 16 patients received grade Garden I and II reductions, and there was no significant difference in the anteroposterior Garden reduction index between the first day after surgery (166.13 ± 5.61) and the 12th month after surgery(164.94 ± 4.49) (P༞0.05) and no significant difference in lateral Garden index between the first day after surgery(171.06 ± 4.46) and the 12th month after surgery(169.38 ± 3.98) (P༞0.05). According to the Hip Harris score scale, 13 patients received excellent and 3 patients received good. The postoperative Hip Harris Score(17.19 ± 4.8) was significantly higher than the preoperative score(92.19 ± 3.4), and the difference was statistically significant (P < 0.05). No or mild femoral neck shortness occurred in 12 (75%) patients, moderate shortening occurred in 3 (18.75%) patients, and severe shortening occurred in 1 (6.25%) patient. None of the patients experienced femoral head necrosis, fracture nonunion, or incision infection. One patient developed deep venous thrombosis of lower extremity.Conclusions The Direct Anterior Approach combined with Femoral Neck System is an excellent treatment for irreducible displaced femoral neck fracture and achieved good functional outcomes and anatomical reduction with low complications.