Martyna Fronczek

Dr. Martyna Fronczek


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
AKAdam Konka
Adam Konka
MLMateusz Lejawa
Mateusz Lejawa
JGJadwiga Gaździcka
Jadwiga Gaździcka
ABAneta Bochenek
Aneta Bochenek
MFMartyna Fronczek
Martyna Fronczek
Joanna Katarzyna StrzelczykJoanna Katarzyna Strzelczyk
Joanna Katarzyna Strzelczyk
Background: The COVID-19 pandemic triggered by the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has left a huge mark on everyday lives, introducing restrictions and plunging the global economy. This study aimed to analyze the available epidemiological data from the register of one of the largest laboratories testing for SARS-CoV-2 in the Silesian voivodship of Poland. Methods: This analysis is based upon the epidemiological records collected between 30 March 2020, and 30 April 2021, by the Silesian Park of Medical Technology Kardio-Med Silesia (Zabrze, Poland). In addition, we performed SARS-CoV-2 variant detection in samples from patients reinfected with SARS-CoV-2. Results: Our results confirm that SARS-CoV-2 infections are more common in urban areas. Laboratory-confirmed COVID-19 cases represent 13.21% of all RT-PCR test results during the 13 months of our laboratory diagnostics for SARS-CoV-2 infections. Detection of SARS-CoV-2 variants in samples of potentially reinfected patients showed discrepancies in the results. Conclusions: Due to the higher risk of SARS-CoV-2 infection among the Upper Silesian population, the region is at greater risk of deteriorating economic situation and healthcare as compared to other areas of Poland. RT-PCR methods are inexpensive and suitable for large-scale screening, but they can be untrustworthy so detection of SARS-CoV-2 variants in samples should be confirmed by sequencing.

19 October 2023 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MKMarcin Zbigniew Krasoń
Marcin Zbigniew Krasoń
APAnna Paradowska
Anna Paradowska
MFMartyna Fronczek
Martyna Fronczek
MLMateusz Lejawa
Mateusz Lejawa
NKNatalia Kamieńska
Natalia Kamieńska
MRMarek Radomski
Marek Radomski
Graphene oxide’s (GO) intravascular applications and biocompatibility are not fully explored yet, although it has been proposed as an anticancer drug transporter, antibacterial factor or component of wearable devices. Bivalent cations and the number of particles’ atom layers, as well as their structural oxygen content and pH of the dispersion, all affect the GO size, shape, dispersibility and biological effects. Bovine serum albumin (BSA), an important blood plasma protein, is expected to improve GO dispersion stability in physiological concentrations of the precipitating calcium and magnesium cations to enable effective and safe tissue perfusion. Methods: Four types of GO commercially available aqueous dispersions (with different particle structures) were diluted, sonicated and studied in the presence of BSA and physiological cation concentrations. Nanoparticle populations sizes, electrical conductivity, zeta potential (Zetasizer NanoZS), structure (TEM and CryoTEM), functional groups content (micro titration) and dispersion pH were analyzed in consecutive preparation stages. Results: BSA effectively prevented the aggregation of GO in precipitating concentrations of physiological bivalent cations. The final polydispersity indexes were reduced from 0.66–0.91 to 0.36–0.43. The GO-containing isotonic dispersions were stable with the following Z-ave results: GO1 421.1 nm, GO2 382.6 nm, GO3 440.2 nm and GO4 490.1 nm. The GO behavior was structure-dependent. Conclusion: BSA effectively stabilized four types of GO dispersions in an isotonic dispersion containing aggregating bivalent physiological cations.