Background: This study aimed to investigate the early and longitudinal humoral response in Healthcare Workers (HCWs) after two doses of the BNT162b2 vaccine and to assess the association between metabolic and anthropometric parameters and the humoral response after vaccination. Methods: The study included 243 fully vaccinated HCWs: 25.50% previously infected with SARS-CoV-2 (with prior history of COVID-19—PH) and 74.40%—uninfected, seronegative before the first vaccination (with no prior history of COVID-19—NPH). IgG antibodies were measured, and sera were collected: prior to the vaccination, 21 days after the first dose, and 14 days and 8 months after the second dose. Results: 21 days after the first dose, 90.95% of individuals were seropositive; 14 days after the second dose, persistent immunity was observed in 99.18% HCWs, 8 months after complete vaccination—in 61.73%. Statistical analysis revealed that HCWs with PH had a greater chance of maintaining a humoral response beyond eight months after vaccination. Increased muscle mass, decreased fat mass, and younger age may positively affect long-term immunity. Smokers have a reduced chance of developing immunity compared to non-smokers. Conclusions: Fully vaccinated HCWs with PH are more likely to be seropositive than fully inoculated volunteers with NPH.
The paper presents the optimization of diode laser irradiation of corroded dental implants in order to reduce the number of microorganisms associated peri-implantitis. The research included the identification of microorganisms on the surface of removed dental implants in patients with peri-implantitis and the assessment of the biocidal effectiveness of the diode laser against these microorganisms. Laser desorption/mass spectrometry (MALDI-TOF MS) was used to identify microorganisms and metagens were examined by next generation sequencing (NGS). Irradiation was performed with a diode laser with a wavelength of λ = 810, operating mode: 25 W/15.000 Hz/10 μs, average = 3.84 W with the number of repetitions t = 2 × 15 s and t = 3 × 15 s. The structure and surface roughness of the implants were analysed before and after laser irradiation by optical profilometry and optical microscopy with confocal fixation. In total, 16 species of Gram-positive bacteria and 23 species of Gram-negative bacteria were identified on the surface of the implants. A total of 25 species of anaerobic bacteria and 12 species with corrosive potential were detected. After diode laser irradiation, the reduction in bacteria on the implants ranged from 88.85% to 100%, and the reduction in fungi from 87.75% to 96.77%. The reduction in microorganisms in the abutment was greater than in the endosseous fixture. The applied laser doses did not damage, but only cleaned the surface of the titanium implants. After 8 years of embedding, the removed titanium implant showed greater roughness than the 25-year-old implant, which was not exposed to direct influence of the oral cavity environment. The use of a diode laser in an optimised irradiation dose safely reduces the number of microorganisms identified on corroded dental implants in patients with peri-implantitis.
The aim of the study was to assess the biocidal effectiveness and the effect of 80% and 90% ethanol applied in the form of mist on the surface of textile materials from historical A-BSM objects. The microorganisms used for the tests, namely, Cladosporium cladosporioides, Aspergillus niger and Penicillium chrysogenum, were isolated from the surface of textile objects in the A-BSM. Bacillus subtilis, Staphylococcus aureus, Aspergillus flavus and Aspergillus niger were also used from the American Type Culture Collection (ATCC). Fabric samples were inoculated with microorganisms at a concentration of 105–106 CFU/ml. Ethanol in the form of mist was applied in concentrations of 80% and 90%. Airbrushes VL 0819 and VE 0707 were used for this purpose, where the pressure was 0.2 MPa and the PA HEAD VLH-5 nozzle with a tip of 1.05 mm in diameter was used. In order to achieve more effective disinfection after applying the ethanol mist, samples were stored in PE foil in the conditions of 21 °C ± 1 °C for 22 ± 1 h. After applying the ethanol mist, changes in the properties of the materials were assessed using scanning electron microscopy (SEM). The reduction in the number of microorganisms on modern cotton fabric after the use of ethanol in the form of mist at concentrations of 80% and 90% ranged from 93.27% to 99.91% for fungi and from 94.96% to 100% for bacteria, except for 74.24% for B. subtillis. On the historical fabric, after the time of application of 90% ethanol was shortened to 4 s, the microorganisms were reduced by over 99.93% and S. aureus was completely eliminated. After applying the tested disinfection technique, no changes in fiber morphology were observed on the surface of the model and historical cotton.
(1) Background: Detection of asymptomatic or subclinical human coronavirus SARS-CoV-2 infection in healthcare workers (HCWs) is crucial for understanding the overall prevalence of the new coronavirus and its infection potential in public (non-infectious) healthcare units with emergency wards. (2) Methods: We evaluated the host serologic responses, measured with semi-quantitative ELISA tests (IgA, IgG, IgM abs) in sera of 90 individuals in Hospital no. 4 in Bytom, 84 HCWs in the University Hospital in Opole and 25 in a Miasteczko Śląskie local surgery. All volunteers had negative RT-PCR test results or had not had the RT-PCR test performed within 30 days before sampling. The ELISA test was made at two different time points (July/August 2020) with a 2-weeks gap between blood collections to avoid the “serological window” period. (3) Results: The IgG seropositivity of asymptomatic HCWs varied between 1.2% to 10% (Opole vs. Bytom, p < 0.05; all without any symptoms). IgA seropositivity in HCWs was 8.8% in Opole and 7.14% in Bytom. IgM positive levels in HCWs in Opole and Bytom was 1.11% vs. 2.38%, respectively. Individuals with IgA and IgM seropositivity results were observed only in Opole (1.19%). More studies are needed to determine whether these results are generalizable to other populations and geographic as well as socio-demographic locations. (4) Conclusions: 100% of IgG(+) volunteers were free from any symptoms of infection in the 30 days before first or second blood collection and they had no awareness of SARS-CoV-2 infection. Asymptomatic HCWs could spread SARS-CoV-2 infection to other employees and patients. Only regular HCWs RT-PCR testing can reduce the risk of SARS-CoV-2 spreading in a hospital environment. The benefit of combining the detection of specific IgA with that of combined specific IgM/IgG is still uncertain.
Background: The COVID-19 pandemic triggered by the novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has left a huge mark on everyday lives, introducing restrictions and plunging the global economy. This study aimed to analyze the available epidemiological data from the register of one of the largest laboratories testing for SARS-CoV-2 in the Silesian voivodship of Poland. Methods: This analysis is based upon the epidemiological records collected between 30 March 2020, and 30 April 2021, by the Silesian Park of Medical Technology Kardio-Med Silesia (Zabrze, Poland). In addition, we performed SARS-CoV-2 variant detection in samples from patients reinfected with SARS-CoV-2. Results: Our results confirm that SARS-CoV-2 infections are more common in urban areas. Laboratory-confirmed COVID-19 cases represent 13.21% of all RT-PCR test results during the 13 months of our laboratory diagnostics for SARS-CoV-2 infections. Detection of SARS-CoV-2 variants in samples of potentially reinfected patients showed discrepancies in the results. Conclusions: Due to the higher risk of SARS-CoV-2 infection among the Upper Silesian population, the region is at greater risk of deteriorating economic situation and healthcare as compared to other areas of Poland. RT-PCR methods are inexpensive and suitable for large-scale screening, but they can be untrustworthy so detection of SARS-CoV-2 variants in samples should be confirmed by sequencing.
This study aimed to assess the magnitude of anti-SARS-CoV-2 immunoglobulin G (IgG) titers and Interferon-Gamma Release Assay (IGRA) test results following administration of booster BNT162b2 in 48 ChAd-primed participants (vaccination schedule: ChAd/ChAd/BNT). Whole blood samples were collected: first, before and second, 21 days after the booster dose. The IgG level was measured using chemiluminescent immunoassay; the intensity of the T-cell response—IFNγ concentration—was assessed using IGRA test. At 21 days after the booster, all subjects achieved reactive/positive anti-SARS-CoV-2 IgG, and IGRA test results showed a significant increase compared to the results before booster administration. We compared the results before and after the booster between participants with and without prior history of COVID-19. The IFNγ concentrations in both cohorts were higher in convalescents (both before booster and 21 days after). The IgG titers were subtly lower in COVID-19 convalescents than in naïve but without statistical significance. Data on cell-mediated immunity are scarce, especially with regard to the general population. A better understanding of the complexity of the immune response to SARS-CoV-2 could contribute to developing more effective vaccination strategies.