Introduction: Pre-clinical testing of hemiarthroplasty devices requires that the tribological conditions present in vivo with live cartilage be closely duplicated. A current limitation in the tribological testing of live cartilage involves the use of cell-culture media as lubricant. Study Aim: to develop and test a new hyaluronan-phospholipid based medium (HA–phospholipid medium) that combines the rheological and frictional properties of synovial fluid with the nourishing properties of culture media to keep cells alive. Materials and Methods: The HA–phospholipid medium consisted of culture medium with added phospholipid dipalmitoylphosphatidylcholine (0.3 mg/mL), and hyaluronic acid (2.42 mg/mL). A standard cell culture medium was used as the control. The rheology of each medium was determined using a flat plate configuration. Bovine calf cartilage was used to assess cell viability and friction in each medium. For friction measurements, a cobalt-chrome alloy ball was articulated against cartilage disks immersed in medium. Results: Lipid vesicles 0.1 to 50 μm in diameter were identified in the HA–phospholipid medium. Cartilage cell viability was significantly higher in the HA–phospholipid medium (62% ± 8%, 95% CI) than in control medium (49.5% ± 5%) (p = 0.009). The HA–phospholipid medium exhibited strong shear-thinning behavior, similar to synovial fluid, with viscosities ~100-fold higher at 10 s−1 and 5-fold higher at 20,000 s−1 than the approximately Newtonian control medium. The HA–phospholipid medium also yielded 20% lower friction values than the control medium after one hour of testing. Conclusions: The rheological and friction results indicate that the HA–phospholipid medium is superior to the control cell culture medium in emulating the shear thinning and lubricative properties of natural synovial fluid, making it more clinically relevant for in vitro wear and friction testing with live cartilage.
It is well established that the total protein concentration and albumin-to-globulin ratio influence the wear of ultra-high molecular polyethylene (UHMWPE, “polyethylene”) in joint prostheses. A factor on wear not yet studied, but of possible clinical relevance, is protein cleavage. Such cleavage is expected in the presence of an inflammatory response and as a result of wear processes at the articular interface. The aim of this study was to compare the tribological behavior of polyethylene articulated against an orthopedic wrought CoCrMo alloy for three lubricants: cleaved albumin, uncleaved albumin, and newborn calf serum (control). We hypothesized that the cleavage of albumin will increase the friction and wear rate of polyethylene, with a concomitant roughening of the polymer surface and the generation of larger wear debris particles. Cleavage of the bovine albumin into five fragments was performed by digestion with cyanogen bromide. In pin-on-flat (POF) wear tests of polyethylene pins made of Ticona GUR® 1020/1050 against CoCrMo alloy discs, the cleaved albumin led to the lowest polyethylene wear and highest friction coefficients, whereas albumin led to the highest wear rates. In knee simulator tests, the albumin lubricant also led to a 2.7-fold increase in the tibial insert wear rate compared to the regular bovine serum lubricant (a wear rate for the cleaved albumin could not be obtained). The generated polyethylene wear particles were of increasing size and fibrillar shape in going from serum to albumin to cleaved albumin, although only the shape achieved statistical significance. Unlike bovine serum, cleaved albumin led to wear scars for both the POF and simulator wear tests that closely emulated the morphological features observed on explanted polyethylene tibial inserts from total knee replacements. We posit that the smaller protein fragments can more efficiently adsorb on the surfaces of both the polyethylene and the metal, thus offering protection against wear, while at the same time leading to an increase in friction, particle size, and particle elongation, as the protein fragment films interact adhesively during sliding. The results of this study have implications for pre-clinical wear testing methodology as they suggest that albumin concentration may be more pertinent than total protein concentration for wear testing polyethylene.