David Plusquellic

Dr. David Plusquellic

National Institute of Standards and Technology, 20899-1070 Gaithersburg MD, United States

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2007 in Chemphyschem
Verified
Journal Article
Closed access
PDF file
DPDavid Plusquellic
David Plusquellic
KSKaren Siegrist
Karen Siegrist
EHEdwin J. Heilweil
Edwin J. Heilweil
OEOkan Esenturk
Okan Esenturk

24 April 2014 in Optics Letters
Verified
Journal Article
Closed access
PDF file
DLD. A. Long
D. A. Long
AFA. J. Fleisher
A. J. Fleisher
KDK. O. Douglass
K. O. Douglass
SMStephen Maxwell
Stephen Maxwell
KBK. Bielska
K. Bielska
DPDavid Plusquellic
David Plusquellic
Dual-drive Mach–Zehnder modulators were utilized to produce power-leveled optical frequency combs (OFCs) from a continuous-wave laser. The resulting OFCs contained up to 50 unique frequency components and spanned more than 200 GHz. Simple changes to the modulation frequency allowed for agile control of the comb spacing. These OFCs were then utilized for broadband, multiheterodyne measurements of CO2 using both a multipass cell and an optical cavity. This technique allows for robust measurements of trace gas species and alleviates much of the cost and complexity associated with the use of femtosecond OFCs produced with mode-locked pulsed lasers.

28 April 2013 in Nature Photonics
Verified
Journal Article
Open access
PDF file
GTG.-W. Truong
G.-W. Truong
KDK. O. Douglass
K. O. Douglass
SMStephen Maxwell
Stephen Maxwell
RZR. D. van Zee
R. D. van Zee
DPDavid Plusquellic
David Plusquellic
DLD. A. Long
D. A. Long
Challenging applications in trace gas measurements require low uncertainty and high acquisition rates1,2,3,4. Many cavity-enhanced spectroscopies exhibit significant sensitivity and potential5,6, but their scanning rates are limited by reliance on either mechanical or thermal frequency tuning7. Here, we present frequency-agile, rapid scanning spectroscopy (FARS) in which a high-bandwidth electro-optic modulator steps a selected laser sideband to successive optical cavity modes. This approach involves no mechanical motion and allows for a scanning rate of 8 kHz per cavity mode, a rate that is limited only by the cavity response time itself. Unlike rapidly frequency-swept techniques8,9,10,11, FARS does not reduce the measurement duty cycle, degrade the spectrum's frequency axis or require an unusual cavity configuration. FARS allows for a sensitivity of ∼2 × 10−12 cm−1 Hz−1/2 and a tuning range exceeding 70 GHz. This technique shows promise for fast and sensitive trace gas measurements and studies of chemical kinetics.

22 April 2011 in Optics Express
Verified
Journal Article
Closed access
PDF file
EGEyal Gerecht
Eyal Gerecht
KDKevin O. Douglass
Kevin O. Douglass
DPDavid Plusquellic
David Plusquellic
We report the first demonstration of a broadband trace gas sensor based on chirp-pulse terahertz spectroscopy. The advent of newly developed solid state sources and sensitive heterodyne detectors for the terahertz frequency range have made it possible to generate and detect precise arbitrary waveforms at THz frequencies with ultra-low phase noise. In order to maximize sensitivity, the sample gas is first polarized using sub-μs chirped THz pulses and the free inductive decays (FIDs) are then detected using a heterodyne receiver. This approach allows for a rapid broadband multi-component sensing with low parts in 109 (ppb) sensitivities and spectral frequency accuracy of <20 kHz in real-time. Such a system can be configured into a portable, easy to use, and relatively inexpensive sensing platform.

5 August 2016 in Applied Optics
Verified
Journal Article
Closed access
PDF file
GWGerd A. Wagner
Gerd A. Wagner
DPDavid Plusquellic
David Plusquellic
A ground-based, integrated path, differential absorption light detection and ranging (IPDA LIDAR) system is described and characterized for a series of nighttime studies of CO2, CH4, and H2O. The transmitter is based on an actively stabilized, continuous-wave, single-frequency external-cavity diode laser (ECDL) operating from 1.60 to 1.65 μm. The fixed frequency output of the ECDL is microwave sideband tuned using an electro-optical phase modulator driven by an arbitrary waveform generator and filtered using a confocal cavity to generate a sequence of 123 frequencies separated by 300 MHz. The scan sequence of single sideband frequencies of 600 ns duration covers a 37 GHz region at a spectral scan rate of 10 kHz (100 μs per scan). Simultaneously, an eye-safe backscatter LIDAR system at 1.064 μm is used to monitor the atmospheric boundary layer. IPDA LIDAR measurements of the CO2 and CH4 dry air mixing ratios are presented in comparison with those from a commercial cavity ring-down (CRD) instrument. Differences between the IPDA LIDAR and CRD concentrations in several cases appear to be well correlated with the atmospheric aerosol structure from the backscatter LIDAR measurements. IPDA LIDAR dry air mixing ratios of CO2 and CH4 are determined with fit uncertainties of 2.8 μmol/mol (ppm) for CO2 and 22 nmol/mol (ppb) for CH4 over 30 s measurement periods. For longer averaging times (up to 1200 s), improvements in these detection limits by up to 3-fold are estimated from Allan variance analyses. Two sources of systematic error are identified and methods to remove them are discussed, including speckle interference from wavelength decorrelation and the seed power dependence of amplified spontaneous emission. Accuracies in the dry air retrievals of CO2 and CH4 in a 30 s measurement period are estimated at 4 μmol/mol (1% of ambient levels) and 50 nmol/mol (3%), respectively.

17 July 2018 in Optics Express
Verified
Journal Article
Open access
PDF file
GWGerd A. Wagner
Gerd A. Wagner
DPDavid Plusquellic
David Plusquellic
The specifications and performance of a ground-based differential absorption LIDAR (light detection and ranging) system (DIAL) using an optical parametric oscillator (OPO) are presented. The OPO is injection-seeded with the output of a confocal filter cavity at frequencies generated by an electro-optic phase modulator (EOM) from a fixed-frequency external cavity diode laser (ECDL). The number of seed frequencies, frequency spacings, and duration is controlled with an arbitrary waveform generator (AWG) driving the EOM. Range resolved data are acquired using both photon current and photon counts from a hybrid detection system. The DIAL measurements are performed using a repeating sequence of 10 frequencies spanning a range of 37.5 GHz near 1602.2 nm to sequentially sample CO2 and H2O at 10 Hz. Dry air mixing ratios of CO2 and H2O with a resolution of 250 m and an averaging time of 10 min resulted in uncertainties as low as 6 µmol/mol (ppm) and 0.44 g/kg, respectively. Simultaneous measurements using an integrated path differential absorption (IPDA) LIDAR system and in situ point sensor calibrated to WMO (World Meteorological Organization) gas standards are conducted over two 10 hr nighttime periods to support traceability of the DIAL results. The column averaged DIAL mixing ratios agree with the IPDA LIDAR results to within the measured uncertainties for much of two measurement periods. Some of the discrepancies with the in situ point sensor results are revealed through trends observed in the gradients of the range resolved DIAL data.