A ground-based, integrated path, differential absorption light detection and ranging (IPDA LIDAR) system is described and characterized for a series of nighttime studies of , , and . The transmitter is based on an actively stabilized, continuous-wave, single-frequency external-cavity diode laser (ECDL) operating from 1.60 to 1.65 μm. The fixed frequency output of the ECDL is microwave sideband tuned using an electro-optical phase modulator driven by an arbitrary waveform generator and filtered using a confocal cavity to generate a sequence of 123 frequencies separated by 300 MHz. The scan sequence of single sideband frequencies of 600 ns duration covers a 37 GHz region at a spectral scan rate of 10 kHz (100 μs per scan). Simultaneously, an eye-safe backscatter LIDAR system at 1.064 μm is used to monitor the atmospheric boundary layer. IPDA LIDAR measurements of the and dry air mixing ratios are presented in comparison with those from a commercial cavity ring-down (CRD) instrument. Differences between the IPDA LIDAR and CRD concentrations in several cases appear to be well correlated with the atmospheric aerosol structure from the backscatter LIDAR measurements. IPDA LIDAR dry air mixing ratios of and are determined with fit uncertainties of 2.8 μmol/mol (ppm) for and 22 nmol/mol (ppb) for over 30 s measurement periods. For longer averaging times (up to 1200 s), improvements in these detection limits by up to 3-fold are estimated from Allan variance analyses. Two sources of systematic error are identified and methods to remove them are discussed, including speckle interference from wavelength decorrelation and the seed power dependence of amplified spontaneous emission. Accuracies in the dry air retrievals of and in a 30 s measurement period are estimated at 4 μmol/mol (1% of ambient levels) and 50 nmol/mol (3%), respectively.
The Ti:sapphire (TISA) laser transmitter of the mobile, three-dimensional-scanning water–vapor differential absorption lidar (DIAL) of the University of Hohenheim is described in detail. The dynamically-stable, unidirectional ring resonator contains a single Brewster-cut TISA crystal, which is pumped from both sides with 250 Hz using a diode-pumped frequency-doubled Nd:YAG laser. The resonator is injection seeded and actively frequency-stabilized using a phase-sensitive technique. The TISA laser is operating near 820 nm, which is optimum for ground-based water–vapor DIAL measurements. An average output power of up to 6.75 W with a beam quality factor of is reached. The pointing stability is (rms), the depolarization . The overall optical–optical conversion efficiency is up to 19%. The pulse length is 40 ns with a pulse linewidth of . The short- and long-term frequency stabilities are 10 MHz (rms). A spectral purity of 99.9% was determined by pointing to a stratus cloud in low-elevation scanning mode with a cloud bottom height of .
The specifications and performance of a ground-based differential absorption LIDAR (light detection and ranging) system (DIAL) using an optical parametric oscillator (OPO) are presented. The OPO is injection-seeded with the output of a confocal filter cavity at frequencies generated by an electro-optic phase modulator (EOM) from a fixed-frequency external cavity diode laser (ECDL). The number of seed frequencies, frequency spacings, and duration is controlled with an arbitrary waveform generator (AWG) driving the EOM. Range resolved data are acquired using both photon current and photon counts from a hybrid detection system. The DIAL measurements are performed using a repeating sequence of 10 frequencies spanning a range of 37.5 GHz near 1602.2 nm to sequentially sample CO2 and H2O at 10 Hz. Dry air mixing ratios of CO2 and H2O with a resolution of 250 m and an averaging time of 10 min resulted in uncertainties as low as 6 µmol/mol (ppm) and 0.44 g/kg, respectively. Simultaneous measurements using an integrated path differential absorption (IPDA) LIDAR system and in situ point sensor calibrated to WMO (World Meteorological Organization) gas standards are conducted over two 10 hr nighttime periods to support traceability of the DIAL results. The column averaged DIAL mixing ratios agree with the IPDA LIDAR results to within the measured uncertainties for much of two measurement periods. Some of the discrepancies with the in situ point sensor results are revealed through trends observed in the gradients of the range resolved DIAL data.
A detailed 3-dimensional calculation of the temperature field of a laser crystal pumped with high average power is presented. The pump configuration, the anisotropy of a Brewster-angle-cut Ti:Sapphire crystal, and the temperature dependence of the thermal conductivity are taken into account. The corresponding focal length of the thermal lens is calculated for pump levels up to 100 W. This refined thermal model is the basis for a optimized resonator design of a high-average power differential absorption lidar system transmitter.
Differential absorption lidar (DIAL) is a unique technique for profiling water vapor from the ground up to the lower stratosphere. For accurate measurements, the DIAL laser transmitter has to meet stringent requirements. These include high average power (up to ) and high single-shot pulse energy, a spectral purity , a frequency instability , and narrow spectral bandwidth (single-mode, ). We describe extensive modeling efforts to optimize the resonator design of a Ti:sapphire ring laser in these respects. The simulations were made for the wavelength range of , which is optimum for ground-based observations, and for both stable and unstable resonator configurations. The simulator consists of four modules: (1) a thermal module for determining the thermal lensing of the Brewster-cut Ti:sapphire crystal collinear pumped from both ends with a high-power, frequency-doubled Nd:YAG laser; (2) a module for calculating the in-cavity beam propagations for stable and unstable resonators; (3) a performance module for simulating the pumping efficiency and the laser pulse energy; and (4) a spectral module for simulating injection seeding and the spectral properties of the laser radiation including spectral impurity. Both a stable and an unstable Ti:sapphire laser resonator were designed for delivering an average power of at a pulse repetition frequency of with a pulse length of approximately , satisfying all spectral requirements. Although the unstable resonator design is more complex to align and has a higher lasing threshold, it yields similar efficiency and higher spectral purity at higher overall mode volume, which is promising for long-term routine operations.
A high-power Ti:Sapphire ring laser with injection seeding at 820 nm is presented. Pumping a Brewster-cut crystal with 23-W pump power at 532 nm resulted in single-frequency operation with average power of 6 W.