Claus von der Burchard

Dr. Claus von der Burchard

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2020 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Open access
PDF file
CBClaus von der Burchard
Claus von der Burchard
MMMoritz Moltmann
Moritz Moltmann
JTJan Tode
Jan Tode
CEChristoph Ehlken
Christoph Ehlken
HSHelge Sudkamp
Helge Sudkamp
JRJohann Roider
Johann Roider
Purpose: The treatment guidelines for many macular diseases rely on frequent monitoring with optical coherence tomography (OCT). However, the burden of frequent disease control leads to low therapy adherence in real life. OCT home monitoring would address this issue but requires an inexpensive and self-operable device. With self-examination low-cost full-field OCT (SELFF-OCT), our group has introduced a novel technology that may fulfill both requirements. In this pilot study, we report the initial experiences with a clinical prototype. Methods: Fifty-one patients with different macular diseases were recruited in a cross-sectional study. The most common diseases were age-related macular degeneration (AMD; 39/51), diabetic macular edema (DME; 6/51), and retinal vein occlusion (RVO; 3/51). Patients received a short training in device usage and then performed multiple self-scans with the SELFF-OCT device. For comparison, scans with a standard clinical spectral domain (SD-)OCT were taken. Results: After a brief training, 77% of the patients were able to successfully acquire images that were clinically gradable. No significant influence on success could be found for age (p = 0.08) or BCVA (p = 0.97). Relevant disease biomarkers in the most common retinal diseases could be detected. Conclusions: SELFF-OCT was used successfully for retinal self-examination and in the future could be used for retinal home monitoring. Future improvements in technology are expected to improve success rates and image quality. Trial registration: The Trial was registered in the German Trial Register under the number DRKS00013755 on 14.03.2018.

18 June 2018 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
CBClaus von der Burchard
Claus von der Burchard
FTFelix Treumer
Felix Treumer
CEChristoph Ehlken
Christoph Ehlken
SKStefan Koinzer
Stefan Koinzer
KPKonstantine Purtskhvanidze
Konstantine Purtskhvanidze
JRJohann Roider
Johann Roider

27 June 2022 in BMJ Open
Verified
Journal Article
Open access
PDF file
CBClaus von der Burchard
Claus von der Burchard
HSHelge Sudkamp
Helge Sudkamp
Jan TodeJan Tode
Jan Tode
CECristoph Ehlken
Cristoph Ehlken
KPKonstantine Purtskhvanidze
Konstantine Purtskhvanidze
JRJohann Roider
Johann Roider
Objectives Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) is a novel OCT technology that was specifically designed for home monitoring of neovascular age-related macular degeneration (AMD). First clinical findings have been reported before. This trial investigates an improved prototype for patients with AMD and focusses on device operability and diagnostic accuracy compared with established spectral-domain OCT (SD-OCT). Design Prospective single-arm diagnostic accuracy study. Setting Tertiary care centre (University Eye Clinic). Participants 46 patients with age-related macular degeneration. Interventions Patients received short training in device handling and then performed multiple self-scans with the SELFF-OCT according to a predefined protocol. Additionally, all eyes were examined with standard SD-OCT, performed by medical personnel. All images were graded by at least 2 masked investigators in a reading centre. Primary outcome measure Rate of successful self-measurements. Secondary outcome measures Sensitivity and specificity of SELFF-OCT versus SD-OCT for different biomarkers and necessity for antivascular endothelial growth factor (anti-VEGF) treatment. Results In 86% of all examined eyes, OCT self-acquisition resulted in interpretable retinal OCT volume scans. In these patients, the sensitivity for detection of anti-VEGF treatment necessity was 0.94 (95% CI 0.79 to 0.99) and specificity 0.95 (95% CI 0.82 to 0.99). Conclusions SELFF-OCT was used successfully for retinal self-examination in most patients, and it could become a valuable tool for retinal home monitoring in the future. Improvements are in progress to reduce device size and to improve handling, image quality and success rates. Trial registration number DRKS00013755, CIV-17-12-022384.

22 July 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
MSMonty Santarossa
Monty Santarossa
ATAyse Tatli
Ayse Tatli
CBClaus von der Burchard
Claus von der Burchard
JAJulia Andresen
Julia Andresen
JRJohann Roider
Johann Roider
RKReinhard Koch
Reinhard Koch
Optical coherence tomography (OCT) and fundus autofluorescence (FAF) are important imaging modalities for the assessment and prognosis of central serous chorioretinopathy (CSCR). However, setting the findings from both into spatial and temporal contexts as desirable for disease analysis remains a challenge due to both modalities being captured in different perspectives: sparse three-dimensional (3D) cross sections for OCT and two-dimensional (2D) en face images for FAF. To bridge this gap, we propose a visualisation pipeline capable of projecting OCT labels to en face image modalities such as FAF. By mapping OCT B-scans onto the accompanying en face infrared (IR) image and then registering the IR image onto the FAF image by a neural network, we can directly compare OCT labels to other labels in the en face plane. We also present a U-Net inspired segmentation model to predict segmentations in unlabeled OCTs. Evaluations show that both our networks achieve high precision (0.853 Dice score and 0.913 Area under Curve). Furthermore, medical analysis performed on exemplary, chronologically arranged CSCR progressions of 12 patients visualized with our pipeline indicates that, on CSCR, two patterns emerge: subretinal fluid (SRF) in OCT preceding hyperfluorescence (HF) in FAF and vice versa.

30 August 2024 in Lasers in Surgery and Medicine
Verified
Journal Article
Open access
CBClaus von der Burchard
Claus von der Burchard
Yoko MiuraYoko Miura
Yoko Miura
BSBoris Stanzel
Boris Stanzel
Jay ChhablaniJay Chhablani
Jay Chhablani
JRJohann Roider
Johann Roider
Jan TodeJan Tode
Jan Tode
Objectives: Numerous laser and light therapies have been developed to induce regenerative processes in the choroid/retinal pigment epithelium (RPE)/photoreceptor complex, leaving the neuroretina undamaged. These therapies are applied to the macula for the treatment of various diseases, most prominently diabetic maculopathy, retinal vein occlusion, central serous chorioretinopathy, and age‐related macular degeneration. However, the abundance of technologies, treatment patterns, and dosimetry protocols has made understanding these therapies and comparing different approaches increasingly complex and challenging. To address this, we propose a new nomenclature system with a clear categorization that will allow for better understanding and comparability between different laser and light modalities. We propose this nomenclature system as an open standard that may be adapted in future toward new technical developments or medical advancements.Methods: A systematic literature review of reported macular laser and light therapies was conducted. A categorization into a standardized system was proposed and discussed among experts and professionals in the field. This paper does not aim to assess, compare, or evaluate the efficacy of different laser or dosimetry techniques or treatment patterns.Results: The literature search yielded 194 papers describing laser techniques, 50 studies describing dosimetry, 272 studies with relevant clinical trials, and 82 reviews. Following the common therapeutic aim, we propose “regenerative retinal laser and light therapies (RELITE)” as the general header. We subdivided RELITE into four main categories that refer to the intended physical and biochemical effects of temperature increase (photothermal therapy, PTT), RPE regeneration (photomicrodisruption therapy, PMT), photochemical processes (photochemical therapy, PCT), and photobiomodulation (photobiomodulation therapy, PBT).Further, we categorized the different dosimetry approaches and treatment regimens. We propose the following nomenclature system that integrates the most important parameters to enable understanding and comparability:Pattern—Dosimetry—Exposure Time/Frequency, Duty Cycle/Irradiation Diameter/Wavelength—Subcategory—Category.Conclusion: Regenerative retinal laser and light therapies are widely used for different diseases and may become valuable in the future. A precise nomenclature system and strict reporting standards are needed to allow for a better understanding, reproduceable and comparable clinical trials, and overall acceptance. We defined categories for a systematic therapeutic goal‐based nomenclature to facilitate future research in this field.

2 April 2024 in Translational Vision Science & Technology
Verified
Journal Article
Open access
PDF file
CBClaus von der Burchard
Claus von der Burchard
CKChristopher Kren
Christopher Kren
JFJan-Erik Fleger
Jan-Erik Fleger
DTDirk Theisen-Kunde
Dirk Theisen-Kunde
VDVeit Danicke
Veit Danicke
RBRalf Brinkmann
Ralf Brinkmann
Purpose: Subdamaging thermal retinal laser therapy has the potential to induce regenerative stimuli in retinal diseases, but validated dosimetry is missing. Real-time optoacoustic temperature determination and control could close this gap. This study investigates a first in vivo application. Methods: Two iterations of a control module that were optically coupled in between a continuous-wave commercial laser source and a commercial slit lamp were evaluated on chinchilla rabbits. The module allows extraction of the temperature rise in real time and can control the power of the therapy laser such that a predefined temperature rise at the retina is quickly achieved and held constant. Irradiations with aim temperatures from 45°C to 69°C were performed on a diameter of 200 µm and a heating time of 100 ms. Results: We analyzed 424 temperature-guided irradiations in nine eyes of five rabbits. The mean difference between the measured and aim temperature was −0.04°C ± 0.98°C. The following ED50 values for visibility thresholds could be determined: 58.6°C for funduscopic visibility, 57.7°C for fluorescein angiography, and 57.0°C for OCT. In all measurements, the correlation of tissue effect was higher to the temperature than to the average heating laser power used. Conclusions: The system was able to reliably perform temperature-guided irradiations, which allowed for better tissue effect control than simple power control. This approach could enhance the accuracy, safety, and reproducibility of thermal stimulating laser therapy. Translational Relevance: This study is a bridge between preclinical ex vivo experiments and a pilot clinical study.