With the rapid development of ultra-high-voltage (UHV) AC/DC, especially the step-by-step upgrading of the UHV DC transmission scale, security presents new challenges. Commutation failure (CF) is a common fault in line commutated converter (LCC) high-voltage direct current (HVDC) power systems. Once failure happens, it may cause power oscillations in a system. In this paper, taking a two-area AC/DC parallel interconnected power system as the example, based on the impulse response model of second-order linear system, the mechanism of power oscillation on the AC tie-line caused by CF are clarified. It is proved that the peak value of the AC tie-line power oscillation is mainly determined by the DC power and the equivalent CF duration, the frequency and damping ratio of dominant area oscillation mode. Meanwhile, the peak time is mainly determined by the oscillation frequency. Finally, the correctness and effectiveness of the algorithms are verified by a simulation analysis of an extended IEEE-39-bus AC/DC parallel interconnected power system. These research results can provide a basis for the arrangement of the operating modes and the formulation of control measures for interconnected power grids.
To solve the problems of large switching losses and the need for large-capacity electrolytic capacitances in three-phase DC/AC on-board chargers for vehicle-to-grid (V2G) applications, this paper proposes a single-stage bidirectional high-frequency isolated converter that eliminates the need for large-capacity capacitances. Combined with the proposed modulation scheme, it can theoretically reduce the switching loss by about two-thirds with the three-phase converter compared with the conventional modulation scheme, improving the converter’s operating efficiency and power density. Firstly, based on the characteristics of the proposed topology, a hybrid modulation scheme is proposed, which combines a phase-shift modulation scheme based on double modulation waves and a sawtooth carrier with a 1/3 modulation scheme, and the theoretical feasibility of the hybrid modulation scheme is verified using a mathematical modeling equation. Secondly, this paper provides a detailed analysis of the four operating modes of the two full-bridge circuits and the commutation process of the three-phase converter within 1/6 of the fundamental frequency cycle (P1 modulation interval). Then, the control strategy is given for the constant-current and constant-voltage charging and constant-current discharging for electric vehicle batteries. Finally, simulation results verify the correctness of the proposed topology and modulation scheme in vehicle–grid interaction.
1 July 2020 in Journal of Physics: Conference Series
The unbalanced three-phase may occur in distributed network with large-scale uncontrolled charging loads of electric vehicles plugged in, at present, most of the researches on the coordinated electric vehicles charging and discharging strategies are based on the assumption of single-phase power networks, the load balancing constraints of three-phase are not considered. In this paper, a centralized charging and discharging optimization model for electric vehicles is established aiming to achieve a valley-filling concept, it can allocate electric vehicles demand during valley hours. Based on this, a distributed charging and discharging optimization method for electric vehicles considering three-phase load balancing constraints is proposed, and then the centralized optimization problem is decomposed into multiple sub-optimization problems, and a penalty term is added to the single electric vehicle charging and discharging optimization objective function. Solve the three-phase load imbalance problem in distribution network operation, and use CPLEX solver to solve the optimization model in MATLAB. Combining with information interaction mechanism, through the method of iteratively correcting the virtual electricity price, the orderly intelligent charging and discharging of electric vehicles can be realized. The IEEE 33-node distribution system is used for simulation analysis to verify the characteristics and effectiveness of the proposed method.
With increasing renewable penetration, heterogeneous hydropower resources in active distribution networks exhibit distinct dynamic voltage support characteristics, which makes capacity-based or fixed-weight indices insufficient for state-dependent assessment. This paper proposes an operating-state-aware hydropower dynamic support index (HDSI) and an HDSI-guided hierarchical voltage-control strategy. Conventional synchronous hydropower, variable-speed hydropower, and pumped storage units in synchronous condenser mode are uniformly characterized by a dynamic reactive power margin, response capability, and spatial support efficiency. State-dependent weights are continuously blended according to critical bus voltage deficits and their evolution, and the resulting HDSI is embedded into supervisory reactive power coordination. On a modified IEEE 33-bus system, the proposed HDSI achieves a Spearman correlation of 0.680 with actual dynamic support contribution, compared with 0.655 for the fixed-weight HDSI, with a statistically significant improvement. Under the representative main fault, the proposed control reduces voltage recovery time from 0.344 to 0.172 s and decreases hydropower saturation exposure by 12.9% relative to the fixed-weight method while maintaining comparable voltage recovery. Across 48 structured and 60 randomized scenarios, the control success rate reaches 100%, with a maximum online QP solution time of 12.440 ms. These results demonstrate effective state-aware support assessment and coordinated resource utilization.
19 May 2019 in Lecture Notes in Electrical Engineering