This article proposes a dual heat source heat pump bathroom unit with preheater which is feasible for a single family. The system effectively integrates the air source heat pump (ASHP) and wastewater source heat pump (WSHP) technologies, and incorporates a preheater to recover shower wastewater heat and thus improve the total coefficient of performance (COP) of the system, and it has no electric auxiliary heating device, which is favorable to improve the security of the system operation. The process simulation software ASPEN PLUS, widely used in the design and optimization of thermodynamic systems, was used to simulate various cases of system use and to analyze the impact of the preheater on the system. The average COP value of a system with preheater is 6.588 and without preheater it is 4.677. Based on the optimization and analysis, under the standard conditions of air at 25 °C, relative humidity of 70%, wastewater at 35 °C, wastewater flow rate of 0.07 kg/s, tap water at 15 °C, and condenser outlet water temperature at 50 °C, the theoretical COP of the system can reach 9.784 at an evaporating temperature of 14.96 °C, condensing temperature of 48.74 °C, and preheated water temperature of 27.19 °C.
Mn-Ce/FA (M) and Mn-Ce/FA-TiO2 (M), using fly ash (FA) with and without TiO2 as the carriers, were prepared by an integral molding technique. With the increase of TiO2 content, the rates of NO conversion and denitration of Mn-Ce/FA-TiO2 (M) increased, and the NO2 and N2O formation rates decreased. It is found that TiO2 could effectively inhibit the excessive oxidation of NO and the generation of N2O. The effects of space velocity, oxygen concentration and ammonia nitrogen ratio on three types of nitrogen oxides (NO, NO2, N2O) and denitration rates of the Mn-Ce/FA (M) and Mn-Ce/FA-30%TiO2 (M) were further investigated. In addition, it is demonstrated that Mn-Ce/FA (M) and Mn-Ce/FA-30%TiO2 (M) were more suitable to be used in the environment of low sulfur and less water.
An experimental study on a plate gravity heat pipe (PGHP) with inner cavity size of length 100 mm (X), width 2.5 mm (Y), and height 210 mm (Z) with acetone as the working fluid was carried out. The effects of heating power inputs (80–180 W) and fluid filling ratios (25%, 48%, and 55%) on the start-up temperature, start-up time, temperature difference, and relative thermal resistance on the Z-axis of the PGHP in a vacuum of 1 × 10−3 Pa were studied at unsteady state. Furthermore, the gas-liquid two-phase behavior of the interior working fluid of PGHP, and the coupling heat transfer behavior of the boiling liquid and the condensate were observed through a visualizable window under different experimental conditions. The results show that, with the increase of heating power input, the start-up temperature of the PGHP increases and the start-up time is shortened. The start-up temperature of the PGHP was around 33 °C and the start-up time was about 320 s at the heating power input of 120 W and working fluid filling ratio of 55%. The relative thermal resistance and the temperature difference on the Z-axis of the PGHP increase firstly and then decrease with the increase of heating power input at unsteady state. The complex gas-liquid two-phase behavior of the PGHP mainly includes: the formation and growth of bubbles, the merging and break up of bubbles, and the coupling heat transfer between boiling liquid and condensate, which demonstrate that the novel SVPGHP can be used to effectively study the heat transfer process of PGHP.