Martina De Luca

Dr. Martina De Luca

Department of Medicine, Surgery and Dentistry "Scuola Medica Salernitana", University of Salerno, Salerno, Campania, Italy
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 September 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MBMaddalena DE BERNARDO
Maddalena DE BERNARDO
Livio VitielloLivio Vitiello
Livio Vitiello
MLMartina De Luca
Martina De Luca
AMAniello La Marca
Aniello La Marca
Nicola RosaNicola Rosa
Nicola Rosa
Ultrasonographic appraisal of the optic nerve sheath diameter has become popular in recent years as a useful diagnostic tool to detect intracranial pressure variations. Intracranial hypertension is a life-threatening disease with possible poor clinical outcomes and can be caused by a variety of neurological and non-neurological conditions. Considering the latter, increases in intracranial pressure have also been described during several surgical procedures. Ocular ultrasonography might be utilized to identify intracranial pressure increases by evaluating optic nerve sheath diameter variations. The aim of this review is to provide a wide overview on the use of the optic nerve ultrasound evaluation to detect intracranial pressure changes during surgical procedures, also discussing the pitfalls of the B-scan technique, the most widely used for such a purpose. PubMed medical database, Web of Science and Scopus were used to carry out this review. The present review showed that ocular ultrasonography could be considered a valuable diagnostic tool in the surgical setting to indirectly assess intracranial pressure. However, the use of the B-scan ultrasound should always be coupled with the standardized A-scan technique for a more accurate, precise and trustworthy ultrasound assessment.

1 September 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Ferdinando CioneFerdinando Cione
Ferdinando Cione
MBMaddalena DE BERNARDO
Maddalena DE BERNARDO
MSMargherita Di Stasi
Margherita Di Stasi
MLMartina De Luca
Martina De Luca
RARosa Albano
Rosa Albano
Nicola RosaNicola Rosa
Nicola Rosa
Background/Objectives: To evaluate the advanced lens measurement approach (ALMA) formula accuracy using different lens constants available on the user group for laser interference biometry (ULIB) and IOL Con platforms. Methods: In this retrospective, comparative, case-series study, 150 eyes of 160 patients with previous myopic Photorefractive Keratectomy (PRK) or laser-assisted in situ keratomileusis (LASIK), who underwent uneventful cataract surgery and IOL implantation, were examined. The ALMA formula was evaluated to calculate the refractive prediction error (PE), analysing four different categories of lens constants: both nominal and optimized A-Constant for SRKT, which are available on the ULIB and IOL Con platforms. An additional analysis was carried out in this study, evaluating if a decreased ULIB optimized constant (DUOC) with different fixed factors (−1.2 −1.3 −1.4 −1.5) could improve refractive outcomes. Median absolute error (MedAE) and percentage of eyes within ±0.50 and ±1.00 diopters (D) of prediction error were measured as the main outcomes. Results: Comparing the lens factors available on ULIB and IOL Con platforms, the ALMA formula reported a lower MedAE and higher percentages of eyes with a refractive PE within 1.0 D using ULIB nominal constants (all p < 0.05). Using DUOC (−1.3), and there was a statistically significant improvement of both MedAE and of the percentages of eyes with PE within ±0.50 D with the ALMA method compared to nominal ULIB constants (all p < 0.05). Conclusions: The impact of different lens factors in the IOL power calculation after myopic LRS should be carefully evaluated. The ALMA formula, in the absence of optimized constants by zeroing the mean error, should be used by subtracting 1.3 from the optimized ULIB constants available on the IOL Con website. This finding suggests further studies to test which of these constants could work better with the other post-refractive surgery formulas.

10 February 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Nicola RosaNicola Rosa
Nicola Rosa
MGMarco Gioia
Marco Gioia
RORachele Orlando
Rachele Orlando
MLMartina De Luca
Martina De Luca
EDEleonora D’aniello
Eleonora D’aniello
MBMaddalena DE BERNARDO
Maddalena DE BERNARDO
The use of choroidal vascularization to diagnose and follow-up ocular and systemic pathologies has been consolidated in recent research. Unfortunately, the choroidal parameters can be different depending on the lighting settings of optical coherence tomography (OCT) images. The purpose of this study was to examine whether the brightness of OCT images could influence the measurements of choroidal parameters obtained by processing and analyzing scientific images with the ImageJ program. In this observational, prospective, non-randomized study, 148 eyes of 74 patients with a mean age of 30.7 ± 8.5 years (ranging from 23 to 61 years) were assessed. All patients underwent a complete ophthalmological examination including slit lamp, fundus oculi, ocular biometry, corneal tomography and spectral domain (SD) OCT evaluations of the foveal region in the enhanced depth imaging (EDI) mode. OCT images at two different brightness levels were obtained. The total choroidal area (TCA), choroidal vascularity index (CVI), stromal choroidal area (SCA) and luminal choroidal area (LCA) at both lower and higher brightness levels were measured. To avoid the bias of operator-dependent error, the lower and higher brightness TCAs were obtained using two methods: the manual tracking mode and fixed area. At the two different brightness levels, LCA, SCA and CVI measurements showed statistically significant changes (p < 0.05), whereas the TCA differences were not statistically significant (p > 0.05). According to the results of this study, highlighting that brightness could affect LCA, SCA and CVI parameters, care should be taken during OCT image acquisition.

22 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MBMaddalena DE BERNARDO
Maddalena DE BERNARDO
FDFrancesco Diana
Francesco Diana
MGMarco Gioia
Marco Gioia
MLMartina De Luca
Martina De Luca
MTMaria Francesca Tepedino
Maria Francesca Tepedino
Marina PicilloMarina Picillo
Marina Picillo
Progressive supranuclear palsy (PSP) is a rare neurodegenerative disease. Recently, several retinal layers in PSP compared to healthy controls. were found to be thinner. However, no studies evaluating the correlation between retinal layers and cerebral white matter changes, nor eventual choroidal changes in PSP, have been conducted so far. The goals of the present study were to explore potential differences in choroidal structure between PSP and healthy controls, and to describe the relationship between retinal layers’ thickness and volume, using spectral-domain optical coherence tomography (SD-OCT) and age-related white matter change scores (ARWMC) using magnetic resonance imaging (MRI) of the brain. Choroidal structures of 26 PSP patients and 26 healthy controls using standard SD-OCT with an enhanced depth imaging (EDI) approach were analyzed; then, retinal the structures of 16 of these PSP patients using standard SD-OCT were examined; finally, the same patients underwent brain MRI, and their cerebral white matter changes were calculated. Non-statistically significant differences between PSP patients’ and healthy controls’ choroidal structure were found. On the contrary, PSP patients’ inner retinal layers (INR), retinal pigmented epithelium (RPE) and all retinal layers’ thicknesses in the macular region were found to be significantly correlated with ARWMC, independently from age and axial length (AL). PSP patients’ neurological alterations go hand in hand with retinal ones, independently from age and axial length. Our results suggest a mutual relationship between cerebral and retinal structure pathological alterations. On the other hand, no significant differences in the choroidal evaluation compared to healthy controls have been found.


19 May 2023 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Closed access
AMAndrea Valerio Marino
Andrea Valerio Marino
MLMartina De Luca
Martina De Luca
MGMarco Gioia
Marco Gioia