Foivos Leonidas Mouzakis

Mr. Foivos Leonidas Mouzakis

Institute of Physiology, University Hospital RWTH Aachen, Aachen, North Rhine-Westphalia, Germany
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2024 in Biomedicines
Verified
Journal Article
Open access
PDF file
FMFoivos Leonidas Mouzakis
Foivos Leonidas Mouzakis
FHFlutura Hima
Flutura Hima
AKAli Kashefi
Ali Kashefi
JGJohannes Greven
Johannes Greven
Lothar RinkLothar Rink
Lothar Rink
JSJan W. Spillner
Jan W. Spillner
Extracorporeal circulation (ECC) is frequently implemented in a vast array of modalities such as hemodialysis, cardiopulmonary bypass, extracorporeal membrane oxygenation (ECMO), and others. Patients receiving any such therapy are frequently encumbered with chronic inflammation, which is inherently accompanied by oxidative stress. However, ECC treatments themselves are also responsible for sustaining or promoting inflammation. On these grounds, an in vitro study was designed to investigate the therapeutic potential of molecular hydrogen (H2) against pro-inflammatory agents in ECC settings. Five miniature ECMO circuits and a small vial (Control) were primed with heparinized blood from healthy adult donors (n = 7). Three of the ECMO systems were injected with lipopolysaccharide (LPS), out of which one was additionally treated with an H2 gas mixture. After 6 h, samples were drawn for the assessment of specific biomarkers (MCP-1, MPO, MDA-a, TRX1, and IL-6). Preliminary results indicate a progressive oxidative and inflammatory response between the six systems. Circulation has triggered inflammation and blood trauma, but the staggering influence of LPS in this outcome is indisputable. Accordingly, hydrogen’s remedial potential becomes immediately apparent as biomarker concentrations tend to be lower in the H2-handled circuit. Future research should have distinct objectives (e.g., dosage/duration/cycle of hydrogen administration) in order to ascertain the optimal protocol for patient treatment.

23 May 2019 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
APAli Poorkhalil
Ali Poorkhalil
FMFoivos Leonidas Mouzakis
Foivos Leonidas Mouzakis
AKAli Kashefi
Ali Kashefi
KMKhosrow Mottaghy
Khosrow Mottaghy
Objectives: Contemporary therapies for chronic kidney disease patients encompass a wide range of hemodialysis treatments, most of which rely greatly on dialyzers and hemofilters. The filtration process taking place in these devices with respect to the hemodynamic characteristics of the flow, has not yet been fully investigated. This study aims at improving the understanding of hemodynamics in a dialyzer by employing experimental methods and mathematical models. Methods: A semiempirical model has been formulated based on the principles of hemodynamics, considering the dominant phenomena of filtration-backfiltration and the corresponding driving forces. An in vitro hemodialysis circuit was accordingly assembled for experimental data acquisition, and subsequently for model validation. The circuit consisted of two dialyzers arranged in sequential order, in pursuance of increasing the number of sampling points. Fresh, heparinized porcine blood was used throughout the course of this study. Pressure and flow data obtained from in vitro investigations with the hemodialysis circuit were used as an input for the semiempirical model. Findings: The model predicted a substantial divergence in the course of hematocrit value along the length of the hollow fibers, which is corroborated by the experimental data. Particularly in certain operational conditions, hematocrit rose from 25% at the inlet to 65% halfway along the dialyzers’ length, to end at 30% at the outlet. Conclusion: Validation of the model’s predictions with experimental data demonstrated a very good agreement, confirming the model’s accuracy. Potential implementation of the model in clinical practice in the future might contribute greatly to an improved hemodialysis experience.

25 January 2022 in The International Journal of Artificial Organs
Verified
Journal Article
Open access
FMFoivos Leonidas Mouzakis
Foivos Leonidas Mouzakis
LKLal Babu Khadka
Lal Babu Khadka
MSMiguel Pereira da Silva
Miguel Pereira da Silva
KMKhosrow Mottaghy
Khosrow Mottaghy
The prevalence of oxidative and inflammatory stress in end-stage renal disease (ESRD) patients has often been associated with chronic haemodialysis therapies. Over the past decades, several reports have shown the potential of hydrogen molecule as an antioxidant in the treatment of various medical conditions in animal models, as well as in pilot studies with human patients. Recently, a hydrogen-enriched dialysate solution has been introduced, holding promise in reducing the oxidative and/or inflammatory complications arising during haemodialysis. To this end, a standardised measuring method to determine the levels of hydrogen in dialysate and subsequently in blood is required. This study explores the possibility of quantifying hydrogen concentration using a novel contactless sensor that detects dissolved hydrogen in liquids. An experimental circuit is assembled to validate the sensitivity and accuracy of the hydrogen monitoring system (Pureron Japan Co., Ltd) through in vitro investigations with physiological solutions. Measurements of dissolved molecular hydrogen concentration are corroborated by an established oxygen sensor providing continuous partial pressure readings. The relationship between the applied H2 content in the gaseous mixture and the H2 concentration value at equilibrium is linear. At the same time, the hydrogen monitoring system has a rather long response time, and its readings seem to slightly diverge from sensor to sensor as well as at different temperatures. For this reason, a sensor recalibration might be necessary, which could become part of the product’s ongoing development. Nevertheless, the aforementioned minor deficiencies can be mostly considered negligible in applications such as haemodialysis.

27 September 2023 in Mathematics
Verified
Journal Article
Open access
PDF file
LKLal Babu Khadka
Lal Babu Khadka
FMFoivos Leonidas Mouzakis
Foivos Leonidas Mouzakis
AKAli Kashefi
Ali Kashefi
FHFlutura Hima
Flutura Hima
JSJan W. Spillner
Jan W. Spillner
KMKhosrow Mottaghy
Khosrow Mottaghy
Membrane artificial lungs (oxygenators) are used in cardiopulmonary surgery as well as, in some cases, in severe lung disease to support the natural lung by means of ECMO (extracorporeal membrane oxygenation). The oxygen and carbon dioxide transfer rates of any oxygenator are usually assessed by considering several blood gas parameters, such as oxygen saturation, hemoglobin concentration, partial pressure of oxygen and carbon dioxide, bicarbonate concentration, and pH. Here, we report a set of semi-empirical equations that calculate such parameters directly from their partial pressures and assess the acid–base balance during ECMO. The implementation of this equation set permits the evaluation of any oxygenator, existing or prototypes in development, as well as the development of clinical decision-making tools for predicting the blood gas state and acid–base balance during surgical interventions and ECMO. The predicted results are then compared with experimental data obtained from in vitro gas exchange investigations with a commercial oxygenator using fresh porcine blood. The high correlation, R2>0.95, between the predicted and the experimental data suggests a possibility of using such empirical equations in the simulation of gas transfer in a cardiopulmonary system with an oxygenator for any venous inlet blood gas data and also for estimating the acid–base balance during such therapy.

7 November 2023 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
FMFoivos Leonidas Mouzakis
Foivos Leonidas Mouzakis
AKAli Kashefi
Ali Kashefi
JSJan Spillner
Jan Spillner
SRStephan Rütten
Stephan Rütten
KMKhosrow Mottaghy
Khosrow Mottaghy
FHFlutura Hima
Flutura Hima
Objectives: Extracorporeal life support (ECLS) pertains to therapeutic and prophylactic techniques utilized in a wide range of medical applications, with severe pulmonary diseases being the most prominent cases. Over the past decades, little progress has been made in advancing the basic principles and properties of gas exchangers. Here, in an unconventional approach, dialysis hollow fibers are handled with silicone to create a purely diffusive coating that prevents plasma leakage and promotes gas exchange. Methods: Commercial dialyzers of varying surface area and fiber diameter have been coated with silicone, to determine the impact of each parameter on performance. The impermeability of the silicone layer has been validated by pressurization and imaging methods. SEM images have revealed a homogeneous silicone film coating the lumen of the capillaries, while fluid dynamic investigations have confirmed its purely diffusive nature. Results: The hemodynamic behavior and the gas exchange efficiency of the silicone-coated prototypes have been investigated in vitro with porcine blood under various operating conditions. Their performance has been found to be similar to that of a commercial PMP oxygenator. Conclusions: This novel class of gas exchangers is characterized by high versatility and expeditious manufacturing. Intraoperability between conventional ECLS systems and dialysis machines broadens the range of application infinitely. Ultimately, long-term clinical applicability ought to be determined over in vivo animal investigations.

12 April 2023 in The International Journal of Artificial Organs
Verified
Journal Article
Open access
FHFlutura Hima
Flutura Hima
SKSebastian Kalverkamp
Sebastian Kalverkamp
AKAli Kashefi
Ali Kashefi
KMKhosrow Mottaghy
Khosrow Mottaghy
RZRachad Zayat
Rachad Zayat
FMFoivos Leonidas Mouzakis
Foivos Leonidas Mouzakis
Objectives: Aim of this work was to characterize possible central anatomical configurations in which a future artificial lung (AL) could be connected, in terms of oxygenation performance. Methods: Pulmonary and systemic circulations were simulated using a numerical and an in vitro approach. The in vitro simulation was carried out in a mock loop in three phases: (1) normal lung, (2) pulmonary shunt (50% and 100%), and (3) oxygenator support in three anatomical configurations: right atrium-pulmonary artery (RA-PA), pulmonary artery-left atrium (PA-LA), and aorta-left atrium (Ao-LA). The numerical simulation was performed for the oxygenator support phase. The oxygen saturation (SO2) of the arterial blood was plotted over time for two percentages of pulmonary shunt and three blood flow rates through the oxygenator. Results: During the pulmonary shunt phase, SO2 reached a steady state value (of 68% for a 50% shunt and of nearly 0% for a 100% shunt) 20 min after the shunt was set. During the oxygenator support phase, physiological values of SO2 were reached for RA-PA and PA-LA, in case of a 50% pulmonary shunt. For the same conditions, Ao-LA could reach a maximum SO2 of nearly 60%. Numerical results were congruous to the in vitro simulation ones. Conclusions: Both in vitro and numerical simulations were able to properly characterize oxygenation properties of a future AL depending on its placement. Different anatomical configurations perform differently in terms of oxygenation. Right to right and right to left connections perform better than left to left ones.