Jan W. Spillner

Prof. Dr. Jan W. Spillner


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2015 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
RKRüdger Kopp
Rüdger Kopp
KDKatja Dommann
Katja Dommann
RRRolf Rossaint
Rolf Rossaint
GSGereon Schälte
Gereon Schälte
OGOliver Grottke
Oliver Grottke
GMGernot Marx
Gernot Marx
In this observational study near infrared spectroscopy (NIRS) was evaluated as a non-invasive monitor of impaired tissue oxygenation (StO2) after cardiac surgery. StO2, cardiac output, mixed venous oxygen saturation and mean arterial pressure were compared with lactate clearance as established measure for sufficient tissue perfusion and oxygen metabolism. Forty patients after cardiac surgery (24 aortocoronary bypass grafting, 5 heart valve, 3 ascending aorta and 8 combined procedures) were monitored until postoperative day 1 with NIRS of the thenar muscle (InSpectra™ StO2-monitor, Hutchinson Technology), a pulmonary-artery catheter and intermittent blood gas analyses for the assessment of lactate clearance. StO2 was reduced 4 h after surgery (75 ± 6 %), but recovered at day 1 (84 ± 5 %), while lactate concentration remained increased. Using uni- and multivariate regression analysis, minimum StO2 (r = 0.46, p <0.01) and cardiac index (r = 0.40, p <0.05) correlated with lactate clearance at day 1, while minimum mixed venous saturation and mean arterial pressure did not. In a receiver-operating characteristics (ROC) analysis, minimum StO2 (with a threshold of 75 %) predicted a lactate clearance <10 % at day 1 with an area under the ROC-curve of 0.83, a sensitivity of 78 % and a specificity of 88 %. In the subgroup with StO2 <75 %, troponin and creatine kinase MB were significantly increased at day 1. StO2 below 75 % in the first hours after surgery was a better early indicator of persistent impaired lactate clearance at day 1 than cardiac index, mixed venous oxygen saturation or mean arterial pressure.

Verified
Journal Article
Open access
PDF file
TATeresa Autschbach
Teresa Autschbach
NHNima Hatam
Nima Hatam
KDKoray Durak
Koray Durak
OGOliver Grottke
Oliver Grottke
Michael DreherMichael Dreher
Michael Dreher
AKAlexander Kersten
Alexander Kersten
It remains unclear to what extent the outcomes and complications of extracorporeal membrane oxygenation (ECMO) therapy in COVID-19 patients with acute respiratory distress syndrome (ARDS) differ from non-COVID-19 ARDS patients. In an observational, propensity-matched study, outcomes after ECMO support were compared between 19 COVID-19 patients suffering from ARDS (COVID group) and 34 matched non-COVID-19 ARDS patients (NCOVID group) from our historical cohort. A 1:2 propensity matching was performed based on respiratory ECMO survival prediction (RESP) score, age, gender, bilirubin, and creatinine levels. Patients’ characteristics, laboratory parameters, adverse events, and 90-day survival were analyzed. Patients’ characteristics in COVID and NCOVID groups were similar. Before ECMO initiation, fibrinogen levels were significantly higher in the COVID group (median: 493 vs. 364 mg/dL, p < 0.001). Median ECMO support duration was similar (16 vs. 13 days, p = 0.714, respectively). During ECMO therapy, patients in the COVID group developed significantly more thromboembolic events (TEE) than did those in the NCOVID group (42% vs. 12%, p = 0.031), which were mainly pulmonary artery embolism (PAE) (26% vs. 0%, p = 0.008). The rate of major bleeding events (42% vs. 62%, p = 0.263) was similar. Fibrinogen decreased significantly more in the COVID group than in the NCOVID group (p < 0.001), whereas D-dimer increased in the COVID group (p = 0.011). Additionally, 90-day mortality did not differ (47% vs. 74%; p = 0.064) between COVID and NCOVID groups. Compared with that in non-COVID-19 ARDS patients, ECMO support in COVID-19 patients was associated with comparable in-hospital mortality and similar bleeding rates but a higher incidence of TEE, especially PAE. In contrast, coagulation parameters differed between COVID and NCOVID patients.

10 June 2014 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
AAAndrea Amerini
Andrea Amerini
NHNima Hatam
Nima Hatam
MMMargarita Malasa
Margarita Malasa
DPDesiree Pott
Desiree Pott
LTLachmandath Tewarie
Lachmandath Tewarie
JSJan W. Spillner
Jan W. Spillner
Interventional treatment of tricuspid valve disease has so far received little attention due to the anatomical challenges in a thrombogenic surrounding. In the present study, we present an imaging-based, personalized interventional approach to the therapy of tricuspid regurgitation. In our porcine model, we used rapid prototyping to build a matrix reproducing the geometry of the right atrium that was previously derived from computer tomography (CT) scans. Over this matrix, a braided nitinol device fitting almost completely the right atrium was crafted. An additional tubular stent component was developed to carry a tissue valve prosthesis. This part was designed to be connectable to the annular portion of the main device. In our feasibility study, the crimped device was implanted via jugular access into the right atrium of 12 pigs and expanded subsequently. Following isolated implantation of the device without the valve-carrying component, further procedures included implantation of the whole composite device, including the mentioned tissue valve. Representing a only feasibility study, all implantations were performed under full bypass and direct sight. On-site visualization was performed by both echocardiography and fluoroscopy. Additional imaging was realized by postoperative CT scans. Following implantation, 9 of 12 animals were weaned from cardiopulmonary bypass. Correct positioning of the device and orthodromic blood flow as maintained by the valve prosthesis were demonstrated by echocardiography and fluoroscopy. Postoperative contrast CT evaluation demonstrated proper fitting of the device into the right-sided heart cavities without obstruction of the outflow tract. Autopsy additionally confirmed its correct positioning without major trauma to surrounding structures. We demonstrated the feasibility in principle of a personalized interventional treatment for tricuspid regurgitation using a braided stent, based on individual cardiac imaging, with anchoring forces mainly exerted on the venae cavae and on the inner surface of the right atrium. The design process of this device is a good indicator of the growing potential of an imaging-based personalized simulation and production approach for the treatment of tricuspid valve disease.

21 September 2012 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
AGAndreas Goetzenich
Andreas Goetzenich
IDImke Deppe
Imke Deppe
HSHeike Schnöring
Heike Schnöring
GGGeorge L Gafencu
George L Gafencu
DGDumitrita-Alina Gafencu
Dumitrita-Alina Gafencu
AMAjay Moza
Ajay Moza
Operative risk scoring algorithms identify patients with severe AS for transcatheter valve implantation in whom the anticipated operative mortality for conventional surgery would be considered prohibitive. We compared the three risk scores EuroScore 1 (LES), society of thoracic surgeons’ (STS) score and ACEF (age-creatinine-ejection fraction score) to the readjusted EuroScore 2 recently presented.

Verified
Journal Article
Open access
PDF file
KDKoray Durak
Koray Durak
KNKatharina Nubbemeyer
Katharina Nubbemeyer
RZRashad Zayat
Rashad Zayat
JSJan W. Spillner
Jan W. Spillner
SDSlavena Dineva
Slavena Dineva
AKAlexander Kersten
Alexander Kersten
Background: Abnormal liver function tests can identify severe cardiopulmonary failure. The aspartate transaminase/alanine transaminase (AST/ALT) ratio, or the De Ritis ratio, is commonly used to evaluate acute liver damage. However, its prognostic value in pulmonary embolism (PE) is unknown. Methods: Two cohorts, including patients with intermediate- and high-risk PEs, were established: one with an abnormal baseline AST/ALT ratio (>1) and another with a normal baseline AST/ALT ratio (<1). The primary outcome was a 60-day mortality. Secondary outcomes included peak N-terminal pro-brain-natriuretic-peptide (NT-proBNP) levels, complications, and the need for critical care treatment. To assess the effect of abnormal AST/ALT ratios, inverse probability weighted (IPW) analyses were performed. Results: In total, 230 patients were included in the analysis, and 52 (23%) had an abnormal AST/ALT ratio. After the IPW correction, patients with an abnormal AST/ALT ratio had a significantly higher mortality rate and peak NT-proBNP levels. The relative risks of 60-day mortality, shock development, use of inotropes/vasopressors, mechanical ventilation, and extracorporeal life support were 9.2 (95% confidence interval: 3.3–25.3), 10.1 (4.3–24), 2.7 (1.4–5.2), 2.3 (1.4–3.7), and 5.7 (1.4–23.1), respectively. Conclusions: The baseline AST/ALT ratio can be a predictor of shock, multiorgan failure, and mortality in patients with a pulmonary embolism.

2 April 2025 in Biomedicines
Verified
Journal Article
Open access
PDF file
KNKatharina Nubbemeyer
Katharina Nubbemeyer
Julia KrabbeJulia Krabbe
Julia Krabbe
SBSvenja Böll
Svenja Böll
AMAnna Michely
Anna Michely
SKSebastian Kalverkamp
Sebastian Kalverkamp
CMChristian Martin
Christian Martin
Background/Objectives: Pulmonary hypertension is a progressive disease leading to right heart failure. One treatment strategy is to induce vasodilation via the nitric oxide–soluble guanylate cyclase–cyclic guanosine monophosphate (NO–sGC–cGMP) signaling pathway. There are currently two soluble guanylate cyclase stimulators on the market: Riociguat and vericiguat, with vericiguat having a longer half-life and needing to be taken only once a day. This study investigated whether the pharmacological differences between the drugs affect pulmonary vessels and airways. Methods: The effects of vericiguat and riociguat on pulmonary arteries, veins, and airways were studied using rat precision-cut lung slices (PCLS). Vessels were pretreated with endothelin-1 and airways with serotonin. In isolated perfused lungs (IPL), the effects of sGC stimulation on pulmonary artery pressure (PAP), airway resistance, inflammatory cytokine, and chemokine release were quantified. Results: Riociguat and vericiguat caused pulmonary artery dilation in PCLS. During IPL, riociguat was more effective than vericiguat in reducing PAP with a statistically significant reduction of 10%. Both drugs were potent bronchodilators in preconstricted airways (p < 0.001). Only vericiguat reduced airway resistance during IPL, as shown here for the first time. Both drugs significantly reduced IL-6 and IL-1ß levels, while riociguat also reduced VEGF-A and KC-GRO levels. Conclusions: Riociguat and vericiguat had three main effects in the two rat ex-vivo models: They dilated the pulmonary arteries, induced bronchodilation, and reduced inflammation. These properties could make sGC stimulators useful for treating diseases associated with endothelial dysfunction. In the future, vericiguat may provide an alternative treatment to induce bronchodilation in respiratory diseases.