Rachid RAHOUADJ

Prof. Rachid RAHOUADJ


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2017 in Stem Cell Research & Therapy
Verified
Journal Article
Open access
PDF file
LALéonore Avercenc-Léger
Léonore Avercenc-Léger
PGPhilippe Guerci
Philippe Guerci
JVJean-Marc Virion
Jean-Marc Virion
GCGhislaine Cauchois
Ghislaine Cauchois
SHSébastien Hupont
Sébastien Hupont
LRLoïc Reppel
Loïc Reppel
The umbilical cord is becoming a notable alternative to bone marrow (BM) as a source of mesenchymal stromal cells (MSC). Although age-dependent variations in BM-MSC are well described, less data are available for MSC isolated from Wharton’s jelly (WJ-MSC). We initiated a study to identify whether obstetric factors influenced MSC properties. We aimed to evaluate the correlation between a large number of obstetric factors collected during pregnancy and until peripartum (related to the mother, the labor and delivery, and the newborn) with WJ-MSC proliferation and chondrogenic differentiation parameters. Correlations were made between 27 obstetric factors and 8 biological indicators including doubling time at passage (P)1 and P2, the percentage of proteoglycans and collagens, and the relative transcriptional expression of Sox-9, aggrecans, and total type 2 collagen (Coll2T). Amongst the obstetric factors considered, birth weight, the number of amenorrhea weeks, placental weight, normal pregnancy, and the absence of preeclampsia were identified as relevant factors for cell expansion, using multivariate linear regression analysis. Since all the above parameters are related to term, we concluded that WJ-MSC from healthy, full-term infants exhibit greater proliferation capacity. As for chondrogenesis, we also observed that obstetric factors influencing proliferation seemed beneficial, with no negative impact on MSC differentiation. Awareness of obstetric factors influencing the proliferation and/or differentiation of WJ-MSC will make it possible to define criteria for collecting optimal umbilical cords with the aim of decreasing the variability of WJ-MSC batches produced for clinical use in cell and tissue engineering.

1 December 2014 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Cédric LaurentCédric Laurent
Cédric Laurent
PLPierre Latil
Pierre Latil
DDDamien Durville
Damien Durville
RRRachid RAHOUADJ
Rachid RAHOUADJ
GCGeindreau Christian
Geindreau Christian
JGJean-François Ganghoffer
Jean-François Ganghoffer

19 February 2014 in Processes
Verified
Journal Article
Open access
PDF file
Cédric LaurentCédric Laurent
Cédric Laurent
CVCedryck Vaquette
Cedryck Vaquette
CMCéline Martin
Céline Martin
EGEmmanuel Guedon
Emmanuel Guedon
XWXiude Wu
Xiude Wu
XWXiong Wang
Xiong Wang
Tissue engineering may constitute a promising alternative to current strategies in ligament repair, providing that suitable scaffolds and culture conditions are proposed. The objective of the present contribution is to present the design and instrumentation of a novel multi-chamber tension-torsion bioreactor dedicated to ligament tissue engineering. A preliminary biological evaluation of a new braided scaffold within this bioreactor under dynamic loading is reported, starting with the development of a dedicated seeding protocol validated from static cultures. The results of these preliminary biological characterizations confirm that the present combination of scaffold, seeding protocol and bioreactor may enable us to head towards a suitable ligament tissue-engineered construct.

Verified
Journal Article
Open access
PDF file
LALéa Aubert
Léa Aubert
MDMarie Dubus
Marie Dubus
HRHassan Rammal
Hassan Rammal
CBCamille Bour
Camille Bour
CMCéline Mongaret
Céline Mongaret
HKHalima Kerdjoudj
Halima Kerdjoudj
Maintenance of mesenchymal stem cells (MSCs) requires a tissue-specific microenvironment (i.e., niche), which is poorly represented by the typical plastic substrate used for two-dimensional growth of MSCs in a tissue culture flask. The objective of this study was to address the potential use of collagen-based medical devices (HEMOCOLLAGENE®, Saint-Maur-des-Fossés, France) as mimetic niche for MSCs with the ability to preserve human MSC stemness in vitro. With a chemical composition similar to type I collagen, HEMOCOLLAGENE® foam presented a porous and interconnected structure (>90%) and a relative low elastic modulus of around 60 kPa. Biological studies revealed an apparently inert microenvironment of HEMOCOLLAGENE® foam, where 80% of cultured human MSCs remained viable, adopted a flattened morphology, and maintained their undifferentiated state with basal secretory activity. Thus, three-dimensional HEMOCOLLAGENE® foams present an in vitro model that mimics the MSC niche with the capacity to support viable and quiescent MSCs within a low stiffness collagen I scaffold simulating Wharton’s jelly. These results suggest that haemostatic foam may be a useful and versatile carrier for MSC transplantation for regenerative medicine applications.

15 December 2015 in Journal of Non-Equilibrium Thermodynamics
Verified
Journal Article
Closed access
JGJean-François Ganghoffer
Jean-François Ganghoffer
RRRachid RAHOUADJ
Rachid RAHOUADJ
JBJulien Boisse
Julien Boisse
SFSamuel Forest
Samuel Forest
The process of bone remodeling includes a cycle of repair, renewal, and optimization. This adaptation process, in response to variations in external loads and chemical driving factors, involves three main types of bone cells: osteoclasts, which remove the old pre-existing bone; osteoblasts, which form the new bone in a second phase; osteocytes, which are sensing cells embedded into the bone matrix, trigger the aforementioned sequence of events. The remodeling process involves mineralization of the bone in the diffuse interface separating the marrow, which contains all specialized cells, from the newly formed bone. The main objective advocated in this contribution is the setting up of a modeling and simulation framework relying on the phase field method to capture the evolution of the diffuse interface between the new bone and the marrow at the scale of individual trabeculae. The phase field describes the degree of mineralization of this diffuse interface; it varies continuously between the lower value (no mineral) and unity (fully mineralized phase, e.g. new bone), allowing the consideration of a diffuse moving interface. The modeling framework is the theory of continuous media, for which field equations for the mechanical, chemical, and interfacial phenomena are written, based on the thermodynamics of irreversible processes. Additional models for the cellular activity are formulated to describe the coupling of the cell activity responsible for bone production/resorption to the kinetics of the internal variables. Kinetic equations for the internal variables are obtained from a pseudo-potential of dissipation. The combination of the balance equations for the microforce associated to the phase field and the kinetic equations lead to the Ginzburg–Landau equation satisfied by the phase field with a source term accounting for the dissipative microforce. Simulations illustrating the proposed framework are performed in a one-dimensional situation showing the evolution of the diffuse interface separating new bone from marrow.

15 December 2015 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
LSL. Siad
L. Siad
JJJ. Jing
J. Jing
JBJulien Braux
Julien Braux
MDMarie Dubus
Marie Dubus
Frédéric VelardFrédéric Velard
Frédéric Velard
JGJ. -F. Ganghoffer
J. -F. Ganghoffer
The objective of this computational study was to propose a rapid procedure in obtaining an estimation of elastic moduli of solid phases of porous natural-polymeric biomaterials used for bone tissue engineering. This procedure was based on the comparison of experimental results to finite element (FE) responses of parallelepiped so-called representative volume elements (rev) of the material at hand. To address this issue a series of quasi-static unconfined compression tests were designed and performed on three prepared cylindrical biopolymer samples. Subsequently, a computed tomography scan was performed on fabricated specimens and two 3D images were reconstructed. Various parallelepiped revs of different sizes and located at distinct places within both constructs were isolated and then analyzed under unconfined compressive loads using FE modelling. In this preliminary study, for the sake of simplicity, the dried biopolymer solid is assumed to be linear elastic.