With the gradual development of offshore wind farms toward large-scale and long-distance trends, economically efficient methods for correcting and transmitting offshore wind energy have garnered increasing attention. The rational and effective evaluation of offshore wind power collection and transmission methods has become an urgent issue. To address this, a comprehensive evaluation model for collection and transmission systems, considering factors such as network losses, lifecycle costs, and reliability, was established. This proposed model was applied to multiple sets of typical collection and transmission scenarios, utilizing an improved TOPSIS comprehensive evaluation method based on dynamic combination weighting to achieve the comprehensive optimization of collection and transmission schemes. Case studies have validated the feasibility of the comprehensive evaluation model. The results indicate that with an increase in offshore distance, the AC/DC collection and transmission system is superior to the all-AC collection and transmission system, and the all-DC collection system exhibits potential cost advantages.
In order to harness a greater share of wind energy resources, offshore wind energy projects are venturing into deep-sea locations. In this progression, the issue of grid integration control becomes increasingly challenging. Traditional Model Predictive Control (MPC) has been introduced in offshore wind energy grid integration control due to its merits, such as not requiring modulators, dispensing with decoupling, incorporating constraint handling, and facilitating online optimization. However, it heavily relies on a model and consequently experiences a substantial loss of control effectiveness in the face of system parameter variations. In light of this, this study presents an active-disturbance-rejection-based three-vector sequence model predictive control approach. This method effectively mitigates the influence caused by changes in system parameters, endowing the system with self-disturbance rejection capabilities and enhancing its fault recovery abilities. The method employs self-disturbance control to track voltage reference values and employs the concept of sequence control to eliminate weighting factors in the cost function. Furthermore, it employs three-vector control to achieve error-free operation. The simulation results confirmed that the proposed method effectively minimizes voltage and power transients. It demonstrated superior control effectiveness and shorter response times, enabling the system to rapidly restore to a stable operational state following disturbances.