Flora Marzia Liotti

Dr. Flora Marzia Liotti

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Journal of Clinical Microbiology
Verified
Journal Article
Closed access
PDF file
BFB. Fiori
B. Fiori
TDT. D'Inzeo
T. D'Inzeo
AGA. Giaquinto
A. Giaquinto
GMG. Menchinelli
G. Menchinelli
FLFlora Marzia Liotti
Flora Marzia Liotti
TST. Spanu
T. Spanu
Despite the current reliance on blood cultures (BCs), the diagnosis of bloodstream infections (BSIs) can be sped up using new technologies performed directly on positive BC bottles. Two methods (the MALDI BioTyper system and FilmArray blood culture identification [BCID] panel) are potentially applicable. In this study, we performed a large-scale clinical evaluation (1,585 microorganisms from 1,394 BSI episodes) on the combined use of the MALDI BioTyper and FilmArray BCID panel compared to a reference (culture-based) method. As a result, the causative organisms of 97.7% (1,362/1,394) of the BSIs were correctly identified by our MALDI BioTyper and FilmArray BCID-based algorithm. Specifically, 65 (5.3%) out of 1,223 monomicrobial BCs that provided incorrect or invalid identifications with the MALDI BioTyper were accurately detected by the FilmArray BCID panel; additionally, 153 (89.5%) out of 171 polymicrobial BCs achieved complete identification with the FilmArray BCID panel. Conversely, full use of the MALDI BioTyper would have resulted in the identification of only 1 causative organism in 97/171 (56.7%) of the polymicrobial cultures. By applying our diagnostic algorithm, the median time to identification was shortened (19.5 h versus 41.7 h with the reference method; P < 0.001), and the minimized use of the FilmArray BCID panel led to a significant cost savings. Twenty-six out of 31 microorganisms that could not be identified were species/genera not designed to be detected with the FilmArray BCID panel, indicating that subculture was not dispensable for a few of our BSI episodes. In summary, the fast and effective testing of BC bottles is realistically adoptable in the clinical microbiology laboratory workflow, although the usefulness of this testing for the management of BSIs remains to be established.

9 June 2018 in European Journal of Clinical Microbiology & Infectious Diseases
Verified
Journal Article
Closed access
PDF file
GAGiulia De Angelis
Giulia De Angelis
BFBarbara Fiori
Barbara Fiori
GMGiulia Menchinelli
Giulia Menchinelli
TDTiziana D’iNzeo
Tiziana D’iNzeo
FLFlora Marzia Liotti
Flora Marzia Liotti
TSTeresa Spanu
Teresa Spanu

19 February 2019 in Frontiers in Microbiology
Verified
Journal Article
Open access
PDF file
GMGiulia Menchinelli
Giulia Menchinelli
FLFlora Marzia Liotti
Flora Marzia Liotti
BFBarbara Fiori
Barbara Fiori
GAGiulia De Angelis
Giulia De Angelis
TDTiziana D'INzeo
Tiziana D'INzeo
TSTeresa Spanu
Teresa Spanu
Blood culture (BC) is still the standard for diagnosing bloodstream infections (BSIs), especially those caused by bacteria and fungi. Infection-complicating sepsis or septic shock often occurs at BSI onset, making necessary to improve the diagnostic yield of positive BCs. Among the BC systems currently available, the BACT/ALERT® VIRTUO® (VIRTUO) system has been developed to shorten time to detection (TTD) of positive BCs. In this study, we assessed TTD for 330 clinically relevant species including 14 Gram-positive, 14 Gram-negative, and 5 yeast isolates in spiked human blood samples that were tested in parallel with VIRTUO BACT/ALERT® 3D (BTA3D) and BACTEC™ FX (BACTEC) systems. We inoculated 30 colony-forming unit (CFU) from each microbial suspension into BACT/ALERT® Plus or BACTEC™ Plus (aerobic/anaerobic or pediatric) BC bottles, and we used two different blood volumes to simulate, respectively, the BCs collected from adult and pediatric patients. Of 2,610 bottles tested, 2,600 (99.6%) signaled positive in the three systems. Only the BACTEC system did not detect Staphylococcus lugdunensis isolates in anaerobic bottles. Among adult simulated cultures, the median TTD was significantly shorter for aerobic/anaerobic bottles incubated in VIRTUO (11.6 h and 10.1 h) compared to bottles incubated in either BTA3D (13.3 and 12.3 h) or BACTEC (13.5 and 12.2 h) system. Among pediatric simulated cultures, the median TTD was significantly shorter for bottles incubated in VIRTUO (11.2 h) compared to bottles incubated in either the BTA3D (13.0 h) or BACTEC (12.5 h) system. Compared to BTA3D and/or BACTEC systems, VIRTUO allowed faster growth detection for most of the 33 microbial species tested. Notable examples were Salmonella spp. (7.4 h by VIRTUO vs. 10.1 h and 9.2 h by either BTA3D or BACTEC) and Streptococcus agalactiae (8.1 h by VIRTUO vs. 10.3 and 9.4 h by either BTA3D or BACTEC). The few notable exceptions included Stenotrophomonas maltophilia and some Candida species. Together, these findings confirm that VIRTUO has greater potential of improving the laboratory detection of bacteremia and fungemia than the progenitor BTA3D or the competitor BACTEC system.

1 January 2019 in Journal of Antimicrobial Chemotherapy
Verified
Journal Article
Open access
PDF file
GAGiulia De Angelis
Giulia De Angelis
BPBrunella Posteraro
Brunella Posteraro
GMGiulia Menchinelli
Giulia Menchinelli
FLFlora Marzia Liotti
Flora Marzia Liotti
TSTeresa Spanu
Teresa Spanu
Maurizio SanguinettiMaurizio Sanguinetti
Maurizio Sanguinetti
To compare the performance of the Accelerate Pheno™ system with that of the conventional phenotypic VITEK® 2 system for rapid antimicrobial susceptibility testing (AST) of bacterial pathogens from positive blood culture (PBC) samples, based on the reference broth microdilution (BMD) method. Prospectively collected PBCs that represented patient-unique bloodstream infection episodes were included. For PBC samples showing monomicrobial growth (n = 86), AST was performed using both Accelerate Pheno™ and VITEK® 2 systems directly from PBC broth. Colony isolates derived from subculture of PBC broth were then used for BMD testing. AST results were interpreted according to 2017 EUCAST breakpoints. The overall categorical agreement between Accelerate Pheno™ system and BMD was 92.7% (467/504) for Gram-negative organisms and 99.0% (95/96) for Gram-positive organisms, with rates for very major errors of 3.6% (6/166), major errors 2.2% (9/416) and minor errors 3.8% (23/600). The overall categorical agreement between the VITEK® 2 system and BMD was 91.7% (463/505) for Gram-negative organisms and 99.0% (97/98) for Gram-positive organisms, with rates of very major errors of 2.4% (4/169), major errors 1.0% (4/416) and minor errors 5.8% (35/603). Importantly, unlike the VITEK® 2 system, no false-susceptible results occurred with two colistin-resistant organism-growing PBCs tested using the Accelerate Pheno™ system. Based on these findings, the Accelerate Pheno™ system can be a valid alternative for the rapid AST of Gram-negative and Gram-positive bacteria in bloodstream infections.

1 July 2019 in Antimicrobial Agents and Chemotherapy
Verified
Journal Article
Closed access
PDF file
LGLiliana Giordano
Liliana Giordano
BFBarbara Fiori
Barbara Fiori
TDTiziana D’inzeo
Tiziana D’inzeo
GPGabriella Parisi
Gabriella Parisi
FLFlora Marzia Liotti
Flora Marzia Liotti
TSTeresa Spanu
Teresa Spanu
We directly tested 484 organisms from clinical ( n = 310) and simulated ( n = 174) positive blood cultures using the NG-Test Carba 5 assay for carbapenemase-producing Enterobacterales detection. The assay identified all but 4 of the KPC (170/171), OXA-48-like (22/22), VIM (19/21), and NDM (14/15) producers with no false positives.

1 July 2017 in Diagnostic Microbiology and Infectious Disease
Verified
Journal Article
Closed access
MCMarco Coppi
Marco Coppi
AAAlberto Antonelli
Alberto Antonelli
TGTommaso Giani
Tommaso Giani
TSTeresa Spanu
Teresa Spanu
FLFlora Marzia Liotti
Flora Marzia Liotti
Gian Maria RossoliniGian Maria Rossolini
Gian Maria Rossolini