Siamak Saifzadeh

Dr. Siamak Saifzadeh

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 February 2020 in Nature Protocols
Verified
Journal Article
Closed access
PDF file
DSDavid S. Sparks
David S. Sparks
SSSiamak Saifzadeh
Siamak Saifzadeh
FSFlavia Medeiros Savi
Flavia Medeiros Savi
CDConstantin E. Dlaska
Constantin E. Dlaska
ABArne Berner
Arne Berner
Dietmar Werner HutmacherDietmar Werner Hutmacher
Dietmar Werner Hutmacher

16 June 2020 in Tissue Engineering Part B: Reviews
Verified
Journal Article
Closed access
MGMichelle Griffin
Michelle Griffin
Nathan CastroNathan Castro
Nathan Castro
OBOnur Bas
Onur Bas
SSSiamak Saifzadeh
Siamak Saifzadeh
PBPeter Butler
Peter Butler
Dietmar Werner HutmacherDietmar Werner Hutmacher
Dietmar Werner Hutmacher
Reconstructive surgery aims to restore tissue defects by replacing them with similar autologous tissue to achieve good clinical outcomes. However, often the defect is too large or the tissue available is limited, requiring synthetic materials to restore the anatomical shape and partial function. The utilization of three-dimensional (3D) printing allows for the manufacture of implants with complex geometries and internal architecture that more closely matches the required clinical needs. Synthetic polymers offer certain advantages over natural polymers as biomedical materials due to their ability to more closely mimic the mechanical and chemical properties of the native tissue. Synthetic polymer materials such as poly(lactic acid) and acrylonitrile butadiene styrene are easily 3D printed to generate 3D objects due to their flexibility in their chemical and mechanical properties and physical form. Polyurethanes (PUs) are widely used as short- and long-term, implantable medical devices due to their good mechanical properties, biocompatibility, and hemocompatibility. This article provides an overview on the advancement of 3D printable PU-based materials for biomedical applications. A summary of the chemical structure and synthesis of PUs is provided to explain how PUs may be processed into medical devices using additive manufacturing techniques. Currently, PUs are being explored by several 3D printing approaches, including fused filament fabrication, bioplotting, and stereolithography, to fabricate complex implants with precise patterns and shapes with fine resolution. PU scaffolds using 3D printing have shown good cell viability and tissue integration in vivo . The important limitations of PU printing are identified to stimulate future research. PUs offer a biocompatible, synthetic polymeric material that can be 3D printed to manufacture implants that are tailored to meet specific anatomical, mechanical, and biological requirements for biomedical applications.

2 May 2022 in Biomaterials
Verified
Journal Article
Open access
JSJoseph A.M. Steele
Joseph A.M. Steele
AMAxel C. Moore
Axel C. Moore
JSJean-Philippe St-Pierre
Jean-Philippe St-Pierre
SMSeth D. McCullen
Seth D. McCullen
AGAdam J. Gormley
Adam J. Gormley
MSMolly M. Stevens
Molly M. Stevens
Articular cartilage is comprised of zones that vary in architecture, extracellular matrix composition, and mechanical properties. Here, we designed and engineered a porous zonal microstructured scaffold from a single biocompatible polymer (poly [ϵ-caprolactone]) using multiple fabrication strategies: electrospinning, spherical porogen leaching, directional freezing, and melt electrowriting. With this approach we mimicked the zonal structure of articular cartilage and produced a stiffness gradient through the scaffold which aligns with the mechanics of the native tissue. Chondrocyte-seeded scaffolds accumulated extracellular matrix including glycosaminoglycans and collagen II over four weeks in vitro. This prompted us to further study the repair efficacy in a skeletally mature porcine model. Two osteochondral lesions were produced in the trochlear groove of 12 animals and repaired using four treatment conditions: (1) microstructured scaffold, (2) chondrocyte seeded microstructured scaffold, (3) MaioRegen™, and (4) empty defect. After 6 months the defect sites were harvested and analyzed using histology, micro computed tomography, and Raman microspectroscopy mapping. Overall, the scaffolds were retained in the defect space, repair quality was repeatable, and there was clear evidence of osteointegration. The repair quality of the microstructured scaffolds was not superior to the control based on histological scoring; however, the lower score was biased by the lack of histological staining due to the limited degradation of the implant at 6 months. Longer follow up studies (e.g., 1 yr) will be required to fully evaluate the efficacy of the microstructured scaffold. In conclusion, we found consistent scaffold retention, osteointegration, and prolonged degradation of the microstructured scaffold, which we propose may have beneficial effects for the long-term repair of osteochondral defects.

1 November 2018 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
PKP.T. Sudheesh Kumar
P.T. Sudheesh Kumar
SHSaeed Mujahid Hashimi
Saeed Mujahid Hashimi
SSSiamak Saifzadeh
Siamak Saifzadeh
SISaso Ivanovski
Saso Ivanovski
CVCedryck Vaquette
Cedryck Vaquette

5 May 2023 in Science Advances
Verified
Journal Article
Open access
DSDavid S. Sparks
David S. Sparks
FSFlavia M. Savi
Flavia M. Savi
CDConstantin E. Dlaska
Constantin E. Dlaska
SSSiamak Saifzadeh
Siamak Saifzadeh
GBGary Brierly
Gary Brierly
Dietmar Werner HutmacherDietmar Werner Hutmacher
Dietmar Werner Hutmacher
A preclinical evaluation using a regenerative medicine methodology comprising an additively manufactured medical-grade ε-polycaprolactone β-tricalcium phosphate (mPCL-TCP) scaffold with a corticoperiosteal flap was undertaken in eight sheep with a tibial critical-size segmental bone defect (9.5 cm 3 , M size) using the regenerative matching axial vascularization (RMAV) approach. Biomechanical, radiological, histological, and immunohistochemical analysis confirmed functional bone regeneration comparable to a clinical gold standard control (autologous bone graft) and was superior to a scaffold control group (mPCL-TCP only). Affirmative bone regeneration results from a pilot study using an XL size defect volume (19 cm 3 ) subsequently supported clinical translation. A 27-year-old adult male underwent reconstruction of a 36-cm near-total intercalary tibial defect secondary to osteomyelitis using the RMAV approach. Robust bone regeneration led to complete independent weight bearing within 24 months. This article demonstrates the widely advocated and seldomly accomplished concept of “bench-to-bedside” research and has weighty implications for reconstructive surgery and regenerative medicine more generally.

2 October 2021 in Polymers
Verified
Journal Article
Open access
PDF file
JRJiongyu Ren
Jiongyu Ren
NKNupur Kohli
Nupur Kohli
VSVaibhav Sharma
Vaibhav Sharma
TSTaleen Shakouri
Taleen Shakouri
ZEZalike Keskin Erdogan
Zalike Keskin Erdogan
EGElena García-Gareta
Elena García-Gareta
We hypothesized that a composite of 3D porous melt-electrowritten poly-ɛ-caprolactone (PCL) coated throughout with a porous and slowly biodegradable fibrin/alginate (FA) matrix would accelerate bone repair due to its angiogenic potential. Scanning electron microscopy showed that the open pore structure of the FA matrix was maintained in the PCL/FA composites. Fourier transform infrared spectroscopy and differential scanning calorimetry showed complete coverage of the PCL fibres by FA, and the PCL/FA crystallinity was decreased compared with PCL. In vitro cell work with osteoprogenitor cells showed that they preferentially bound to the FA component and proliferated on all scaffolds over 28 days. A chorioallantoic membrane assay showed more blood vessel infiltration into FA and PCL/FA compared with PCL, and a significantly higher number of bifurcation points for PCL/FA compared with both FA and PCL. Implantation into a rat cranial defect model followed by microcomputed tomography, histology, and immunohistochemistry after 4- and 12-weeks post operation showed fast early bone formation at week 4, with significantly higher bone formation for FA and PCL/FA compared with PCL. However, this phenomenon was not extrapolated to week 12. Therefore, for long-term bone regeneration, tuning of FA degradation to ensure syncing with new bone formation is likely necessary.