Matthieu Dubreuil

Matthieu Dubreuil

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2012 in Optics Letters
Verified
Journal Article
Closed access
PDF file
MDMatthieu Dubreuil
Matthieu Dubreuil
PBPhilippe Babilotte
Philippe Babilotte
LMLoïc Martin
Loïc Martin
DSDavid Sevrain
David Sevrain
SRSylvain Rivet
Sylvain Rivet
BJBernard Le Jeune
Bernard Le Jeune
An experimental Mueller matrix polarimeter is used to quantify human liver fibrosis by measuring retardance and depolarization of thin biopsies. The former parameter is sensitive to fibrillar collagen, the latter is specifically sensitive to fibrillar collagen around blood vessels, which is not significant for liver fibrosis diagnosis. By using depolarization like a filter, retardance distribution enables distinguishing between disease stages and limits the high degree of observer discrepancy.

13 September 2016 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Aymeric Le GratietAymeric Le Gratiet
Aymeric Le Gratiet
MDMatthieu Dubreuil
Matthieu Dubreuil
SRSylvain Rivet
Sylvain Rivet
YGYann Le Grand
Yann Le Grand
A full Mueller polarimeter was implemented on a commercial laser-scanning microscope. The new polarimetric microscope is based on high-speed polarization modulation by spectral coding using a wavelength-swept laser as a source. Calibration as well as estimation of the measurement errors of the device are reported. The acquisition of Mueller images at the speed of a scanning microscope is demonstrated for the first time. Mueller images of mineral and biological samples illustrate this new polarimetric microscopy.

17 February 2009 in Applied Optics
Verified
Journal Article
Closed access
PDF file
MDMatthieu Dubreuil
Matthieu Dubreuil
SRSylvain Rivet
Sylvain Rivet
BJBernard Le Jeune
Bernard Le Jeune
JCJack Cariou
Jack Cariou
Systematic errors specific to a snapshot Mueller matrix polarimeter are studied. Their origins and effects are highlighted, and solutions for correction and stabilization are proposed. The different effects induced by them are evidenced by experimental results acquired with a given setup and theoretical simulations carried out for more general cases. We distinguish the errors linked to some imperfection of elements in the experimental setup from those linked to the sample under study.

29 March 2010 in Optics Letters
Verified
Journal Article
Closed access
PDF file
MDMatthieu Dubreuil
Matthieu Dubreuil
SRSylvain Rivet
Sylvain Rivet
BJBernard Le Jeune
Bernard Le Jeune
LDLaurent Dupont
Laurent Dupont
An experimental snapshot Mueller matrix polarimeter based on wavelength polarization coding is used to get a time-resolved description of electric-field-induced fast transition within a ferroelectric liquid-crystal cell. The parameters extracted from experimental Mueller matrices are linked to the molecule director distribution to further determine the average trajectory and the collective behavior of these molecules while they switch over to another state.

7 December 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
MDMatthieu Dubreuil
Matthieu Dubreuil
FTFlorine Tissier
Florine Tissier
SRSylvain Rivet
Sylvain Rivet
YGYann Le Grand
Yann Le Grand
Among the multitude of optical polarization contrasts that can be observed in complex biological specimens, linear diattenuation (LD) imaging has received little attention. It is indeed challenging to image LD with basic polarizing microscopes because it is often relatively small in comparison with linear retardance (LR). In addition, interpretation of LD images is not straightforward when experiments are conducted in the visible range because LD can be produced by both dichroism and anisotropic scattering. Mueller polarimetry is a powerful implementation of polarization sensing able to differentiate and measure the anisotropies of specimens. In this article, near infrared transmission Mueller scanning microscopy is used to image LD in thin biological specimen sections made of various proteins with unprecedented resolution and sensitivity. The near infrared spectral range makes it possible to lower the contribution of dichroism to the total linear diattenuation in order to highlight anisotropic scattering. Pixel-by-pixel comparison of LD images with LR and multiphoton images demonstrates that LD is produced by under-resolved structures that are not revealed by other means, notably within the sarcomere of skeletal muscles. LD microscopy appears as a powerful tool to provide new insights into the macro-molecular organization of biological specimens at the sub-microscopic scale without labelling.

19 November 2018 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
MDMatthieu Dubreuil
Matthieu Dubreuil
FTFlorine Tissier
Florine Tissier
LRLucas Le Roy
Lucas Le Roy
JPJean-Pierre Pennec
Jean-Pierre Pennec
SRSylvain Rivet
Sylvain Rivet
YGYann Le Grand
Yann Le Grand
Polarization-resolved second harmonic generation (P-SHG) microscopy is able to probe the sub-micrometer structural organization of myosin filaments within skeletal muscle. In this study, P-SHG microscopy was used to analyze the structural consequences of sepsis, which is the main cause of the critical illness polyneuromyopathy (CIPNM). Experiments conducted on two populations of rats demonstrated a significant difference of the anisotropy parameter between healthy and septic groups, indicating that P-SHG microscopy is promising for the diagnosis of CIPNM. The difference, which can be attributed to a change of myosin conformation at the sub-sarcomere scale, cannot be evidenced by classical SHG imaging.