Aymeric Le Gratiet

Dr. Aymeric Le Gratiet

Istituto Italiano di Tecnologia
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2016 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Aymeric Le GratietAymeric Le Gratiet
Aymeric Le Gratiet
MDMatthieu Dubreuil
Matthieu Dubreuil
SRSylvain Rivet
Sylvain Rivet
YGYann Le Grand
Yann Le Grand
A full Mueller polarimeter was implemented on a commercial laser-scanning microscope. The new polarimetric microscope is based on high-speed polarization modulation by spectral coding using a wavelength-swept laser as a source. Calibration as well as estimation of the measurement errors of the device are reported. The acquisition of Mueller images at the speed of a scanning microscope is demonstrated for the first time. Mueller images of mineral and biological samples illustrate this new polarimetric microscopy.

11 February 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Aymeric Le GratietAymeric Le Gratiet
Aymeric Le Gratiet
AMALI Mohebi
ALI Mohebi
FCFabio Callegari
Fabio Callegari
PBPaolo Bianchini
Paolo Bianchini
ADAlberto Diaspro
Alberto Diaspro
Optical scanning microscopy techniques based on the polarization control of the light have the capability of providing non invasive label-free contrast. By comparing the polarization states of the excitation light with its transformation after interaction with the sample, the full optical properties can be summarized in a single 4×4 Mueller matrix. The main challenge of such a technique is to encode and decode the polarized light in an optimal way pixel-by-pixel and take into account the polarimetric artifacts from the optical devices composing the instrument in a rigorous calibration step. In this review, we describe the different approaches for implementing such a technique into an optical scanning microscope, that requires a high speed rate polarization control. Thus, we explore the recent advances in term of technology from the industrial to the medical applications.

13 November 2018 in OSA Continuum
Verified
Journal Article
Closed access
PDF file
Aymeric Le GratietAymeric Le Gratiet
Aymeric Le Gratiet
LPLuca Pesce
Luca Pesce
MOMichele Oneto
Michele Oneto
RMRiccardo Marongiu
Riccardo Marongiu
GZGiulia Zanini
Giulia Zanini
ADAlberto Diaspro
Alberto Diaspro
Circular dichroism imaging has proved a powerful and simple method for extracting information on chiral molecules without specific fluorescent labels. Numerous mathematical models show that outside the absorption band, the circular dichroism signal comes from the scattering interaction and brings additional information about the organization of biopolymers. With this article, we propose a fast method to control the polarization states without moving parts, by means of a photoelastic modulator. We implemented the technique on a modified commercial confocal microscope realizing a multimodal configuration. We demonstrate its imaging capabilities by studying the organization of chromatin DNA inside isolated cell nuclei.

27 December 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Aymeric Le GratietAymeric Le Gratiet
Aymeric Le Gratiet
MDMarta D’aMora
Marta D’aMora
MDMarti Duocastella
Marti Duocastella
RMRiccardo Marongiu
Riccardo Marongiu
ABArtemi Bendandi
Artemi Bendandi
ADAlberto Diaspro
Alberto Diaspro
Zebrafish are powerful animal models for understanding biological processes and the molecular mechanisms involved in different human diseases. Advanced optical techniques based on fluorescence microscopy have become the main imaging method to characterize the development of these organisms at the microscopic level. However, the need for fluorescence probes and the consequent high light doses required to excite fluorophores can affect the biological process under observation including modification of metabolic function or phototoxicity. Here, without using any labels, we propose an implementation of a Mueller-matrix polarimeter into a commercial optical scanning microscope to characterize the polarimetric transformation of zebrafish preserved at different embryonic developmental stages. By combining the full polarimetric measurements with statistical analysis of the Lu and Chipman mathematical decomposition, we demonstrate that it is possible to quantify the structural changes of the biological organization of fixed zebrafish embryos and larvae at the cellular scale. This convenient implementation, with low light intensity requirement and cheap price, coupled with the quantitative nature of Mueller-matrix formalism, can pave the way for a better understanding of developmental biology, in which label-free techniques become a standard tool to study organisms.

12 February 2015 in Optics Letters
Verified
Journal Article
Closed access
PDF file
Aymeric Le GratietAymeric Le Gratiet
Aymeric Le Gratiet
SRSylvain Rivet
Sylvain Rivet
MDMatthieu Dubreuil
Matthieu Dubreuil
YGYann Le Grand
Yann Le Grand
A new setup is proposed to perform high-speed Mueller polarimetry by spectral coding of polarization in a reflection configuration. The system uses a swept laser source and a photodiode, which results in a simple optical setup that allows measurement of Mueller matrices at 100 kHz repetition rate. A special focus is made on the influence of the cube beam splitter polarimetric response, which is essential to measurements in a reflection configuration. The instrument is first validated on reference samples for single-point measurements, and the effect of a proper system calibration is also demonstrated on polarimetric images. The device is intended to be implemented within a laser scanning microscope to perform multimodal imaging (confocal/multiphoton and Mueller polarimetry).

21 October 2020 in Polymers
Verified
Journal Article
Open access
PDF file
Aymeric Le GratietAymeric Le Gratiet
Aymeric Le Gratiet
RMRiccardo Marongiu
Riccardo Marongiu
ADAlberto Diaspro
Alberto Diaspro
Circular Intensity Differential Scattering (CIDS) provides a differential measurement of the circular right and left polarized light and has been proven to be a gold standard label-free technique to study the molecular conformation of complex biopolymers, such as chromatin. In early works, it has been shown that the scattering component of the CIDS signal gives information from the long-range chiral organization on a scale down to 1/10th–1/20th of the excitation wavelength, leading to information related to the structure and orientation of biopolymers in situ at the nanoscale. In this paper, we review the typical methods and technologies employed for measuring this signal coming from complex macro-molecules ordering. Additionally, we include a general description of the experimental architectures employed for spectroscopic CIDS measurements, angular or spectral, and of the most recent advances in the field of optical imaging microscopy, allowing a visualization of the chromatin organization in situ.