Paola Chiovati

Dr. Paola Chiovati

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2021 in Nutrients
Verified
Journal Article
Open access
PDF file
Giuseppe FanettiGiuseppe Fanetti
Giuseppe Fanetti
Jerry PoleselJerry Polesel
Jerry Polesel
EFElisabetta Fratta
Elisabetta Fratta
EMElena Muraro
Elena Muraro
VLValentina Lupato
Valentina Lupato
GFGiovanni Franchin
Giovanni Franchin
Background: The Prognostic Nutritional Index (PNI) is a parameter of nutritional and inflammation status related to toxicity in cancer treatment. Since data for head and neck cancer are scanty, this study aims to investigate the association between PNI and acute and late toxicity for this malignancy. Methods: A retrospective cohort of 179 head and neck cancer patients treated with definitive radiotherapy with induction/concurrent chemotherapy was followed-up (median follow-up: 38 months) for toxicity and vital status between 2010 and 2017. PNI was calculated according to Onodera formula and low/high PNI levels were defined according to median value. Odds ratio (OR) for acute toxicity were calculated through logistic regression model; hazard ratios (HR) for late toxicity and survival were calculated through the Cox proportional hazards model. Results: median PNI was 50.0 (interquartile range: 45.5–53.5). Low PNI was associated with higher risk of weight loss > 10% during treatment (OR = 4.84, 95% CI: 1.73–13.53 for PNI < 50 versus PNI ≥ 50), which was in turn significantly associated with worse overall survival, and higher risk of late mucositis (HR = 1.84; 95% CI:1.09–3.12). PNI predicts acute weight loss >10% and late mucositis. Conclusions: PNI could help clinicians to identify patients undergoing radiotherapy who are at high risk of acute and late toxicity.

7 December 2023 in Cancers
Verified
Journal Article
Open access
PDF file
SHS M Hasibul Hoque
S M Hasibul Hoque
GPGiovanni Pirrone
Giovanni Pirrone
FMFABIO MATRONE
FABIO MATRONE
ADAlessandra Donofrio
Alessandra Donofrio
Giuseppe FanettiGiuseppe Fanetti
Giuseppe Fanetti
PCPaola Chiovati
Paola Chiovati
Purpose: When autocontouring based on artificial intelligence (AI) is used in the radiotherapy (RT) workflow, the contours are reviewed and eventually adjusted by a radiation oncologist before an RT treatment plan is generated, with the purpose of improving dosimetry and reducing both interobserver variability and time for contouring. The purpose of this study was to evaluate the results of application of a commercial AI-based autocontouring for RT, assessing both geometric accuracies and the influence on optimized dose from automatically generated contours after review by human operator. Materials and Methods: A commercial autocontouring system was applied to a retrospective database of 40 patients, of which 20 were treated with radiotherapy for prostate cancer (PCa) and 20 for head and neck cancer (HNC). Contours resulting from AI were compared against AI contours reviewed by human operator and human-only contours using Dice similarity coefficient (DSC), Hausdorff distance (HD), and relative volume difference (RVD). Dosimetric indices such as Dmean, D0.03cc, and normalized plan quality metrics were used to compare dose distributions from RT plans generated from structure sets contoured by humans assisted by AI against plans from manual contours. The reduction in contouring time obtained by using automated tools was also assessed. A Wilcoxon rank sum test was computed to assess the significance of differences. Interobserver variability of the comparison of manual vs. AI-assisted contours was also assessed among two radiation oncologists for PCa. Results: For PCa, AI-assisted segmentation showed good agreement with expert radiation oncologist structures with average DSC among patients ≥ 0.7 for all structures, and minimal radiation oncology adjustment of structures (DSC of adjusted versus AI structures ≥ 0.91). For HNC, results of comparison between manual and AI contouring varied considerably e.g., 0.77 for oral cavity and 0.11–0.13 for brachial plexus, but again, adjustment was generally minimal (DSC of adjusted against AI contours 0.97 for oral cavity, 0.92–0.93 for brachial plexus). The difference in dose for the target and organs at risk were not statistically significant between human and AI-assisted, with the only exceptions of D0.03cc to the anal canal and Dmean to the brachial plexus. The observed average differences in plan quality for PCa and HNC cases were 8% and 6.7%, respectively. The dose parameter changes due to interobserver variability in PCa were small, with the exception of the anal canal, where large dose variations were observed. The reduction in time required for contouring was 72% for PCa and 84% for HNC. Conclusions: When an autocontouring system is used in combination with human review, the time of the RT workflow is significantly reduced without affecting dose distribution and plan quality.

13 September 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
GPGiovanni Pirrone
Giovanni Pirrone
FMFABIO MATRONE
FABIO MATRONE
PCPaola Chiovati
Paola Chiovati
SMStefania Manente
Stefania Manente
ADAnnalisa Drigo
Annalisa Drigo
MAMichele Avanzo
Michele Avanzo
The aim of this study is to predict local failure after partial prostate re-irradiation for the treatment of isolated locally recurrent prostate cancer by using a machine learning classifier based on radiomic features from pre-treatment computed tomography (CT), positron-emission tomography (PET) and biological effective dose distribution (BED) of the radiotherapy plan. The analysis was conducted on a monocentric dataset of 43 patients with evidence of isolated intraprostatic recurrence of prostate cancer after primary external beam radiotherapy. All patients received partial prostate re-irradiation delivered by volumetric modulated arc therapy. The gross tumor volume (GTV) of each patient was manually contoured from planning CT, choline-PET and dose maps. An ensemble machine learning pipeline including unbalanced data correction and feature selection was trained using the radiomic and dosiomic features as input for predicting occurrence of local failure. The model performance was assessed using sensitivity, specificity, accuracy and area under receiver operating characteristic curves of the score function in 10-fold cross validation repeated 100 times. Local failure was observed in 13 patients (30%), with a median time to recurrence of 36.7 months (range = 6.1–102.4 months). A four variables ensemble machine learning model resulted in accuracy of 0.62 and AUC 0.65. According to our results, a dosiomic machine learning classifier can predict local failure after partial prostate re-irradiation.

14 April 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AVAlessandra Vendrame
Alessandra Vendrame
CCCristina Cappelletto
Cristina Cappelletto
PCPaola Chiovati
Paola Chiovati
LVLorenzo Vinante
Lorenzo Vinante
MPMd. Masud Parvej
Md. Masud Parvej
MAMichele Avanzo
Michele Avanzo
Purpose: to predict eligibility for deep inspiration breath-hold (DIBH) radiotherapy (RT) treatment of patients with left breast cancer from analysis of respiratory signal, using Deep Bidirectional Long Short-Term Memory (BLSTM) recurrent neural networks. Methods: The respiratory traces from 36 patients who underwent DIBH RT were collected. The patients’ RT treatment plans were generated for both DIBH and free-breathing (FB) modalities. The patients were divided into two classes (patient eligible or not), based on the decrease of maximum dose to the left anterior descending (LAD) artery achieved with DIBH, compared to that achieved with FB and ΔDL. Patients with ΔDL > median value of ΔDL within the patient cohort were assumed to be those selected for DIBH. A BLSTM-RNN was trained for classification of patients eligible for DIBH by analysis of their respiratory signals, as acquired during acquisition of the pre-treatment computed tomography (CT), for selecting the window for DIBH. The dataset was split into training (60%) and test groups (40%), and the hyper-parameters, including the number of hidden layers, the optimizer, the learning rate, and the number of epochs, were selected for optimising model performance. The BLSTM included 2 layers of 100 neural units, each followed by a dropout layer with 20% dropout, and was trained in 35 epochs using the Adam optimizer, with an initial learning rate of 0.0003. Results: The system achieved accuracy, specificity, and sensitivity of, F1 score and area under the receiving operating characteristic curve (AUC) of 71.4%, 66.7%, 80.1%, 72.4%, and 69.4% in the test dataset, respectively. Conclusions: The proposed BLSTM-RNN classified patients in the test set eligible for DIBH with good accuracy. These results look promising for building an accurate and robust decision system to provide automated assistance to the radiotherapy team in assigning patients to DIBH.

25 October 2011 in Cancers
Verified
Journal Article
Open access
PDF file
MMMaurizio Mascarin
Maurizio Mascarin
FGFrancesca Maria Giugliano
Francesca Maria Giugliano
ECElisa Coassin
Elisa Coassin
ADAnnalisa Drigo
Annalisa Drigo
PCPaola Chiovati
Paola Chiovati
MTMauro Gaetano Trovò
Mauro Gaetano Trovò
Helical Tomotherapy (HT) is a highly conformal image-guided radiation technique, introduced into clinical routine in 2006 at the Centro di Riferimento Oncologico Aviano (Italy). With this new technology, intensity-modulated radiotherapy (IMRT) is delivered using a helicoidal method. Here we present our dosimetric experiences using HT in 100 children, adolescents and young adults treated from May 2006 to February 2011. The median age of the patients was 13 years (range 1–24). The most common treated site was the central nervous system (50; of these, 24 were craniospinal irradiations), followed by thorax (22), head and neck (10), abdomen and pelvis (11), and limbs (7). The use of HT was calculated in accordance to the target dose conformation, the target size and shape, the dose to critical organs adjacent to the target, simultaneous treatment of multiple targets, and re-irradiation. HT has demonstrated to improve target volume dose homogeneity and the sparing of critical structures, when compared to 3D Linac-based radiotherapy (RT). In standard cases this technique represented a comparable alternative to IMRT delivered with conventional linear accelerator. In certain cases (e.g., craniospinal and pleural treatments) only HT generated adequate treatment plans with good target volume coverage. However, the gain in target conformality should be balanced with the spread of low-doses to distant areas. This remains an open issue for the potential risk of secondary malignancies (SMNs) and longer follow-up is mandatory.