This paper presents a survey of recent developments using Doppler radar sensor in searching and locating an alive person under debris or behind a wall. Locating a human and detecting the vital signs such as breathing rate and heartbeat using a microwave sensor is a non-invasive technique. Recently, many hardware structures, signal processing approaches, and integrated systems have been introduced by researchers in this field. The purpose is to enhance the accuracy of vital signs’ detection and location detection and reduce energy consumption. This work concentrates on the representative research on sensing systems that can find alive people under rubble when an earthquake or other disasters occur. In this paper, various operating principles and system architectures for finding survivors using the microwave radar sensors are reviewed. A comparison between these systems is also discussed.
Radio frequency energy harvesting is being considered for realizing energy efficient relay networks. This letter focuses on decode-and-forward relaying in an energy harvesting network and develops analytical expressions of the outage probability and overall throughput. A three-step scheme has been proposed that allows the bidirectional exchange of information between two nodes via an intermediate relay. The performance of the proposed scheme has been evaluated and compared with a recent work.
Contactless vital signs detection, based on the Dopler radar sensor system, has opened a great opportunity in biomedical applications. The radar sensor system can be used to provide the respiratory information of people without disturbing their comfort. This sensor system promises high accuracy in measuring breathing disorders as it escapes the touching sensors which might cause discomfort to the user, and negatively affect their sleeping habits. Moreover, this sensor system does not require any special environment or depend on temperature and light conditions. In this paper we propose a model to the end users; this model is to be built based on neural networks. Our proposed system can diagnose whether a person has a low, normal, or high breathing rate. This model can be also extended to more specific categories to help doctors to determine breathing disorders in patients. In this work, a continuous wave radar sensor system, based on Vector Network Analyser (VNA), is used to measure the breathing rate remotely. The measured signal from this radar sensor system is then processed for further purposes. Different extracted feature methods are implemented to obtain the breathing rate from the non-contact radar sensor system. A model based on the machine learning technique is investigated to classify the breathing disorder. 31 people who were asked to perform low/normal/high breathing were measured by the CW radar sensor. The measured data was also used to build the machine learning based model. The breathing rate measured by the CW radar sensor system is compared with the reference measurement by the five-point touching Shimmer sensor. The results of the breathing rate is compatible. Two main time-frequency (TF) extraction feature methods, short time Fourier transform (STFT) and continuous Wavelet transform (CWT) were implemented in the proposed system. Under these extraction techniques, some classification approaches were employed and have shown high accuracy in categorizing the respiratory types. The research shows the possibility of building an Artificial Intelligence (AI) module for a non-contact radar sensor system to inform the end user of their breathing situation. This research enables a smarter, and more friendly remote-detecting vital signs sensor system.
This paper presents a solution that prioritises high privacy protection and improves communication throughput for predicting the risk of sexually transmissible infections/human immunodeficiency virus (STIs/HIV). The approach utilised Federated Learning (FL) to construct a model from multiple clinics and key stakeholders. FL ensured that only models were shared between clinics, minimising the risk of personal information leakage. Additionally, an algorithm was explored on the FL manager side to construct a global model that aligns with the communication status of the system. Our proposed method introduced Random Forest Federated Learning for assessing the risk of STIs/HIV, incorporating a flexible aggregation process that can be adjusted to accommodate the capacious communication system. Experimental results demonstrated the significant potential of a solution for estimating STIs/HIV risk. In comparison with recent studies, our approach yielded superior results in terms of AUC (0.97) and accuracy ( $$93\%$$ ). Despite these promising findings, a limitation of the study lies in the experiment for man’s data, due to the self-reported nature of the data and sensitive content. which may be subject to participant bias. Future research could check the performance of the proposed framework in partnership with high-risk populations (e.g., men who have sex with men) to provide a more comprehensive understanding of the proposed framework’s impact and ultimately aim to improve health outcomes/health service optimisation.
Introduction: Applying and leveraging artificial intelligence within the healthcare domain has emerged as a fundamental pursuit to advance health. Data-driven models rooted in deep learning have become powerful tools for use in healthcare informatics. Nevertheless, healthcare data are highly sensitive and must be safeguarded, particularly information related to sexually transmissible infections (STIs) and human immunodeficiency virus (HIV). Methods: We employed federated learning (FL) in combination with homomorphic encryption (HE) for STI/HIV prediction to train deep learning models on decentralized data while upholding rigorous privacy. The dataset included 168,459 data entries collected from eight countries between 2013 and 2018. The data for each country was split into two groups, with 70% allocated for training and 30% for testing. Our strategy was based on two-step aggregation to enhance model performance and leverage the area under the curve (AUC) and accuracy metrics and involved a secondary aggregation at the local level before utilizing the global model for each client. We introduced a dropout approach as an effective client-side solution to mitigate computational costs. Results: Model performance was progressively enhanced from an AUC of 0.78 and an accuracy of 74.4% using the local model to an AUC of 0.94 and an accuracy of 90.7% using the more advanced model. Conclusion: Our proposed model for STI/HIV risk prediction surpasses those achieved by local models and those constructed from centralized data sources, highlighting the potential of our approach to improve healthcare outcomes while safeguarding sensitive patient information.
Vital detection on the basis of Doppler radars has drawn a great deal of attention from researchers because of its high potential for applications in biomedicine, surveillance, and finding people alive under debris during natural hazards. In this research, the signal-to-noise ratio (SNR) of the remote vital-sign detection system is investigated. On the basis of different types of noise, such as phase noise, Gaussian noise, leakage noise between the transmitting and receiving antennae, and so on, the SNR of the system has first been examined. Then the research has focused on the investigation of the detection and false alarm probabilities of the system when the transmission link between the human and the radar sensor system took the Nakagami-m channel model. The analytical model for the false alarm and the detection probabilities of the system have been derived. The proposed theoretical models for the SNR and detection probability match with the simulation and measurement results. These theoretical models have the potential to be used as good references for the hardware development of the vital-sign detection radar sensor system.