Wei-Chao ZHANG

Wei-Chao ZHANG


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
SWShuchao Wang
Shuchao Wang
FWFu Wan
Fu Wan
HZHong Zhao
Hong Zhao
WCWeigen Chen
Weigen Chen
WZWei-Chao Zhang
Wei-Chao Zhang
QZQuan Zhou
Quan Zhou
Currently, in the modern power industry, it is still a great challenge to achieve high sensitivity and uninterrupted-online measurement of large current on the high voltage gridlines. At present, the fiber grating current sensors based on giant magnetostrictive material used in the modern power industry to achieve uninterrupted-online measurement of large currents on high voltage grid lines is a better method, but the sensitivity of this current sensor is relatively low, therefore, it is key to improve the sensitivity of this current sensor. Here we show a sensitivity-enhanced fiber grating current sensor based on giant magnetostrictive material (in the following, simply referred to as the sensitivity-enhanced fiber grating current sensor) that is able to achieve high sensitivity and uninterrupted-online measurement of large currents by means of pressurizing the giant magnetostrictive material. Sampling the power frequency sinusoidal alternating current signals with the amplitudes of 107, 157 and 262 A respectively, based on realistic factors, for the sensitivity-enhanced current sensor, the sensitivities, compared with that of the traditional fiber grating current sensor based on giant magnetostrictive material (in the following, simply referred to as the traditional fiber grating current sensor), were respectively enhanced by 268.96%, 135.72% and 71.57%. Thus the sensitivity-enhanced fiber grating current sensor allows us to solve the issue of high sensitivity and uninterrupted-online measurement of large currents that have been plaguing the power industry in a very simple and low-cost way.

9 July 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JQJixian Qiao
Jixian Qiao
WZWei-Chao Zhang
Wei-Chao Zhang
QCQichao Chen
Qichao Chen
XWXuan Wang
Xuan Wang
HZHong Zhao
Hong Zhao
The traditional fiber optic acoustic emission (AE) sensor, used to detect the partial discharge (PD) in the liquid-solid composite dielectric such as oil-immersed transformers, is not satisfactory in engineering applications due to the limitation of sensitivity and sensor size. This work proposes that the distributed feedback fiber laser (DFB-FL), benefiting from its tiny size and ultra-high sensitivity, is a better choice for PD AE detection. We build the PD AE detection system using erbium-ytterbium co-doped (Er-Yb-co-doped) DFB-FL, with suitable photoelectric components to design the demodulation system and intensity noise of DFB-FL as an index. Noise analysis shows that the average noise amplitude of the system is reduced by 91.67% after digital filtering technology and pump laser power regulation technology. We also use an 80kVA oil-immersed transformer winding structure to construct a liquid-solid composite dielectric PD AE detection platform. Moreover, experiment results in different pump power show that the DFB-FL PD AE detection system can effectively detect the PD AE signal in the environment with sizeable acoustic impedance. The peak-to-peak value of its response is 31.36 times larger than the background noise and 637% higher than piezoelectric transducer sensors (PZT).

18 November 2019 in Journal of Sensors
Verified
Journal Article
Open access
PDF file
QCQi-Chao Chen
Qi-Chao Chen
WZWei-Chao Zhang
Wei-Chao Zhang
HZHong Zhao
Hong Zhao
The insulation of power equipment can be effectively assessed by analyzing the acoustic signals originated from partial discharges (PD). Fabry-Perot (F-P) sensors are capable of detecting PD acoustic signals. Although the frequency bandwidth of an F-P sensor is mainly referred to conventional piezoelectric transducer (PZT) sensor, it is still doubtful to identify a suitable bandwidth for fiber sensors in detection of PD signals. To achieve a suitable bandwidth for an F-P sensor, the frequency distribution of PD acoustic emission is investigated, and an extrinsic F-P sensor is designed to detect acoustic signals generated from PD. F-P sensors with different intrinsic frequencies are fabricated as possible design standards of bandwidth for acoustic detection. PD acoustic signals are detected by these F-P sensors and PZT sensors in the experimental system, in which four typical electrode models are employed. The measured results of frequency performance are analyzed in linear and semilogarithmic coordinates. The results show that F-P sensors can effectively detect PD acoustic emissions in both wideband and narrowband modes. Moreover, F-P sensors achieve a higher sensitivity in the narrowband mode. We propose that intrinsic frequency of the F-P sensor should be designed in the frequency range of 100–170 kHz to obtain maximum sensitivity.

7 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JQJixian Qiao
Jixian Qiao
WZWei-Chao Zhang
Wei-Chao Zhang
YWYanqi Wang
Yanqi Wang
QSQibing Shao
Qibing Shao
JCJianlong Cai
Jianlong Cai
HZHong Zhao
Hong Zhao
The demodulation method of optical fiber sensors utilized in power transformer partial discharge (PD) detection is insufficient for engineering applications. We design a distributed feedback fiber laser (DFB-FL) PD detection system with an asymmetric 3 × 3 coupler and propose an ultra-high signal-to-noise ratio (SNR) demodulation scheme by eliminating the main factors that affect the traditional method using an asymmetric 3 × 3 coupler. The power transformer PD detection results reveal that the proposed scheme is free from 3 × 3 coupler asymmetry issues, with an average SNR of 38.30 dB, which is much higher than the widely used demodulation method and the piezoelectric transducer sensor. The average SNR of the system is increased by 24.2 dB with the proposed method.

4 May 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JQJixian Qiao
Jixian Qiao
WZWei-Chao Zhang
Wei-Chao Zhang
SLShuai Liu
Shuai Liu
HWHao Wu
Hao Wu
HZHong Zhao
Hong Zhao
Active fiber optic acoustic emission (AE) sensors cause external optical feedback (EOF) in engineering applications, resulting in performance loss when used for long-distance partial discharge detection in power transformers. This work employs a distributed feedback fiber laser (DFB-FL) as a sensor to construct a partial discharge detection system. Furthermore, two schemes that improve the long-distance detection performance of DFB-FL are proposed by Suppressing EOF (S-EOF) and Introducing EOF (I-EOF). Then, partial discharge tests in an 80 kVA power transformer validate that both schemes can implement long-distance partial discharge detection. Experimental results indicate that the S-EOF system has a significant signal-to-noise ratio, which is 6.01 dB higher than the piezoelectric transducer (PZT). The S-EOF scheme is suitable for long-term online partial discharge monitoring. The I-EOF system has a high sensitivity for partial discharge detection, and its detectable discharge magnitude is lower than 65.8 pC. The I-EOF scheme is applicable for short-term systemic sampling and daily inspections.

26 April 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
WZWei-Chao Zhang
Wei-Chao Zhang
QYQun Yu
Qun Yu
QCQi-Chao Chen
Qi-Chao Chen
QSQi-Bing Shao
Qi-Bing Shao
JQJi-Xian Qiao
Ji-Xian Qiao
HZHong Zhao
Hong Zhao
The fiber optic interferometer, an instrument for partial discharge (PD) acoustic wave detection, is currently receiving much attention. Due to the high sensitivity, the dual-arm fiber optic interferometers have been used in the field of partial discharge detection for a long time. However, the long-distance guided fiber structure of the dual-arm interferometer is prone to coupling environmental noise, and there are difficulties in matching the optical path difference which is used to generate interference. This paper elaborates on two types of single-arm interferometric fiber optic technology for partial discharge acoustic sensing. Firstly, it summarizes the work in recent years on extrinsic fiber Fabry-Perot interferometer based on Micro-Electro-Mechanical System (MEMS). Meanwhile, the distributed feedback fiber laser (DFB-FL) sensing technology is mainly demonstrated to detect partial discharge acoustic wave signals. Noise suppression is the most important problem for DFB-FL PD measurement. This paper presents the mechanism of relaxation oscillation and self-pulse oscillation in DFB-FL, and a theoretical model is constructed. The adjustment of laser parameters is presented to suppress the oscillation noise. Then, composite cavity reflection model is equivalent to Rayleigh scattering from fiber to control reflection noise interference. Furthermore, demodulation method with low-frequency drift noise suppression is proposed to promote PD detection sensitivity.