The determination of sulcus-to-sulcus measurements has been challenging due to the limitations of current approaches. Ultrasound methods are highly operator-dependent and require extensive training, while traditional optical devices cannot visualize structures posterior to the iris. However, modern optical anterior segment coherence tomography (AS-OCT) devices are changing this paradigm by identifying some anatomical landmarks posterior to the iris. This study evaluates the reproducibility of optical sulcus measurements in the context of sizing a novel accommodative intraocular lens (IOL). Preoperative OCT scans of patients scheduled for cataract surgery were analyzed regarding the dimensions of the ciliary sulcus using a custom scan method with a clinically available anterior segment optical coherence tomographer. Measurements were compared between two different readers, and various derived parameters were compared. The measurements by both readers were highly correlated (R2 > 0.96), and their agreement was excellent (mean difference 0.02 mm with 95% limits of agreement from −0.11 to 0.15 mm). In contrast, the sulcus diameter measurement did not agree well with automatically calculated values, such as the anterior chamber width or white-to-white. This leads to the conclusion that modern swept-source AS-OCT measurements of the ciliary sulcus dimensions are feasible, reproducible, and may be a clinically useful tool.
The VEMoS-AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is recognized as the gold standard for the performance of an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system, and afterwards, a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm, and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, respectively. The agreement between devices was good for AL (limits of agreement, LoA: −0.04 to 0.03 mm) and CCT (LoA: −4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS-AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.
The VEMoS AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is considered the gold standard, for an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system and afterwards a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, re-spectively. The agreement between devices was good for AL (Limits of agreement, LoA: -0.04 to 0.03 mm) and CCT (LoA: -4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.