29 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
TETimo Eppig
Timo Eppig
MSManuel Seer
Manuel Seer
AAAntonio Martinez Abad
Antonio Martinez Abad
ATAlejandro Tello
Alejandro Tello
SSSaskia Schütz
Saskia Schütz
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
The determination of sulcus-to-sulcus measurements has been challenging due to the limitations of current approaches. Ultrasound methods are highly operator-dependent and require extensive training, while traditional optical devices cannot visualize structures posterior to the iris. However, modern optical anterior segment coherence tomography (AS-OCT) devices are changing this paradigm by identifying some anatomical landmarks posterior to the iris. This study evaluates the reproducibility of optical sulcus measurements in the context of sizing a novel accommodative intraocular lens (IOL). Preoperative OCT scans of patients scheduled for cataract surgery were analyzed regarding the dimensions of the ciliary sulcus using a custom scan method with a clinically available anterior segment optical coherence tomographer. Measurements were compared between two different readers, and various derived parameters were compared. The measurements by both readers were highly correlated (R2 > 0.96), and their agreement was excellent (mean difference 0.02 mm with 95% limits of agreement from −0.11 to 0.15 mm). In contrast, the sulcus diameter measurement did not agree well with automatically calculated values, such as the anterior chamber width or white-to-white. This leads to the conclusion that modern swept-source AS-OCT measurements of the ciliary sulcus dimensions are feasible, reproducible, and may be a clinically useful tool.

6 March 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
MJMarina José-Martínez
Marina José-Martínez
AAAntonio Martinez Abad
Antonio Martinez Abad
ARAlejandra Rodriguez
Alejandra Rodriguez
FVFrancesco Versaci
Francesco Versaci
David P PiñeroDavid P Piñero
David P Piñero
The VEMoS-AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is recognized as the gold standard for the performance of an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system, and afterwards, a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm, and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, respectively. The agreement between devices was good for AL (limits of agreement, LoA: −0.04 to 0.03 mm) and CCT (LoA: −4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS-AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.

21 December 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
MJMarina José-Martínez
Marina José-Martínez
AAAntonio Martinez Abad
Antonio Martinez Abad
ARAlejandra Rodriguez
Alejandra Rodriguez
FVFrancesco Versaci
Francesco Versaci
David P PiñeroDavid P Piñero
David P Piñero
The VEMoS AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is considered the gold standard, for an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system and afterwards a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, re-spectively. The agreement between devices was good for AL (Limits of agreement, LoA: -0.04 to 0.03 mm) and CCT (LoA: -4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.