1 June 2009 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
TETimo Eppig
Timo Eppig
KSKatja Scholz
Katja Scholz
ALAndré Löffler
André Löffler
AMArthur Meßner
Arthur Meßner
ALAchim Langenbucher
Achim Langenbucher
To determine the impact of decentration and tilt on the imaging quality of aspheric intraocular lens (IOL) designs in a schematic model eye. Institute of Medical Physics, University of Erlangen-Nuremberg, Erlangen, Germany. A model eye was used to calculate the impact of misalignment on the imaging quality of 6 IOL designs. The crystalline lens in the model eye was replaced with IOL designs with 22.0 diopters nominal refractive power, and the anterior chamber depth (ACD) was set to the estimated ACD value provided by the manufacturer. The retinal position was optimized for the best image quality. The IOLs were decentered up to +/-1.0 mm and tilted up to +/-5 degrees relative to the line of sight. At each position, the modulation transfer function was recorded with 3.0 mm and 4.5 mm pupil diameters. The results between the IOL designs and those of the phakic model eye were then compared. Aberration-correcting IOLs were very sensitive to decentration and tilt. However, the impact of misalignment depended on IOL design. Aberration-free IOLs showed less sensitivity within a wide range of displacement but provided better results than the spherical IOL. Overall, modern aspheric IOLs provided better imaging quality than conventional spherical IOL designs. Aberration-free IOLs were less sensitive to decentration and tilt than aberration-correcting IOLs but provided better image quality than spherical IOLs. Aberration-correcting IOLs have the potential to provide diffraction-limited imaging quality when perfectly aligned.

1 April 2015 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
SGSusanne Goebels
Susanne Goebels
TETimo Eppig
Timo Eppig
SWStefan Wagenpfeil
Stefan Wagenpfeil
ACAlan Cayless
Alan Cayless
Berthold SeitzBerthold Seitz
Berthold Seitz
ALAchim Langenbucher
Achim Langenbucher

26 February 2018 in Current Eye Research
Verified
Journal Article
Closed access
SSSimon Schröder
Simon Schröder
SMStephanie Mäurer
Stephanie Mäurer
TETimo Eppig
Timo Eppig
Berthold SeitzBerthold Seitz
Berthold Seitz
KRKathrin Rubly
Kathrin Rubly
ALAchim Langenbucher
Achim Langenbucher
Purpose: To compare corneal tomography and its statistical uncertainty for measurements obtained by three clinically used corneal tomographers: A Scheimpflug camera (Pentacam HR), a swept source optical coherence tomography system (CASIA SS-1000), and Placido ring imaging (TMS-5). Material and Methods: Repeated measurements with all three devices on 34 normal eyes were used to estimate the repeatability, precision, and mean values of corneal elevation and pachymetry within 8 mm diameter. The repeatability (standard deviation) was calculated for each data point of the corneal elevation data-maps of anterior and posterior cornea as well as for the pachymetry data-maps. Uncertainty on the position of the eye at each measurement might contribute to the differences between elevation data-maps. To take this into account, we defined the precision as the standard deviation for the elevation data-maps of anterior and posterior cornea after correction of misalignment-effects (rotation, translation). The mean elevation and pachymetry data-maps were fitted with Zernike polynomials for interdevice-comparison. Results: Pentacam HR offered the best repeatability and precision for the anterior corneal elevation (<3 and <1.6 μm, respectively). CASIA SS-1000 offered good repeatability and precision with high resolution for posterior corneal elevation, and the best repeatability for pachymetry (<3 μm). TMS-5 measured anterior elevation with similar repeatability to CASIA SS-1000 (<6 μm). The data-maps of the three tomographers could not be used interchangeably. The largest differences were observed for pachymetry and posterior corneal elevation data-maps. Conclusions: Misalignment limited the repeatability of TMS-5 and Pentacam HR, but had little influence on the repeatability of CASIA SS-1000.

1 November 2015 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
TETimo Eppig
Timo Eppig
CSCorinna Spira
Corinna Spira
TTThemistoklis Tsintarakis
Themistoklis Tsintarakis
MEMoatasem El-Husseiny
Moatasem El-Husseiny
ACAlan Cayless
Alan Cayless
ALAchim Langenbucher
Achim Langenbucher
To analyse the optical effect of an artificial hole in the optic centre of posterior chamber phakic intraocular lenses. Institute of Experimental Ophthalmology, Saarland University, Homburg/Saar, Germany. Experimental simulation study. Four eye models with an ametropia of -4 D, -8 D, +4 D, and +8 D were created in the ray tracing software ASAP. Refractive correction of these models was implemented with a model of an Implantable Collamer Lens (ICL). Each eye was set up twice with 1 eye receiving a conventional ICL without a central hole and the second an ICL with a central hole. Ray bundles were traced for lateral visual field angles from 0 to 60 degrees in steps of 1 degree. Ray propagation and retinal illumination were then compared between the 2 ICL models. All eye models showed ghost images originating from the anterior surface of the ICL. Eye models with the ICL with central hole showed additional light spots in the peripheral areas of the retina originating from reflections at the cylindrical wall of the central hole in the ICL. The average intensity of ghost images in the temporal retinal hemisphere was between 30 and 40 dB less than the maximum intensity of the primary image. A central hole within a posterior chamber phakic intraocular lens may cause stray light and ghost images (positive dysphotopsia) although the on-axis visual quality of the eye with the ICL is mostly unaffected. The authors have no financial interest in any of the material presented in this paper.

1 June 2009 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
KSKatja Scholz
Katja Scholz
AMArthur Messner
Arthur Messner
TETimo Eppig
Timo Eppig
HBHolger Bruenner
Holger Bruenner
ALAchim Langenbucher
Achim Langenbucher
To assess corneal asphericity (Q) and evaluate potential factors influencing the shape of the anterior corneal surface. Medical Optics Research Group, Institute of Medical Physics, University of Erlangen-Nuremberg, Erlangen, Germany. In this cross-sectional consecutive study, 3 topographic measurements were taken. Eyes were grouped by age in years (A: or=70), sex, and refraction. The study comprised 487 eyes (205 men, 288 women; age 17 to 81 years). The mean Q of the anterior corneal surface was -0.22 +/- 0.14 (SD) overall, -0.21 +/- 0.12 in Group A, -0.25 +/- 0.11 in Group B, -0.21 +/- 0.15 in Group C, -0.23 +/- 0.14 in Group D, -0.19 +/- 0.17 in Group E, -0.20 +/- 0.15 in Group F, -0.23 +/- 0.13 in men, -0.21 +/- 0.14 in women, -0.19 +/- 0.14 in hyperopes (n = 166; >+0.50 to +6.50 diopters [D]), -0.23 +/- 0.13 in emmetropes (n = 162; -0.50 to +0.50 D), and -0.23 +/- 0.15 in myopes (n = 165; <-0.50 to -8.00 D). There was no significant correlation between Q and age; Q differed significantly between men and women (P = .005), hyperopes and emmetropes (P<.0001), and hyperopes and myopes (P = .001). There were high interindividual variations in the Q value. Thus, proper correction of spherical aberration with intraocular lenses (IOLs) requires sophisticated selection of the asphericity of IOL surfaces based on biometric data and individual corneal Q values.

20 March 2018 in Current Eye Research
Verified
Journal Article
Closed access
TETimo Eppig
Timo Eppig
CSC. Spira-Eppig
C. Spira-Eppig
SGS. Goebels
S. Goebels
Berthold SeitzBerthold Seitz
Berthold Seitz
MEM. El-Husseiny
M. El-Husseiny
ALA. Langenbucher
A. Langenbucher
Purpose: To evaluate whether the inter-eye asymmetry of keratoconus (KC) patients is different from a healthy control group and to investigate how asymmetry changes with increasing severity of the disease. Methods: In this retrospective study, we included both eyes of 350 patients with KC (age 35 ± 13 years) and 68 candidates planned for refractive surgery (control group, age 37 ± 11 years). Inclusion criteria for the KC group were keratoconus in at least one eye with Pentacam Topographical Keratoconus Classification (TKC) of at least 0.5. Patients eligible for refractive surgery in both eyes were included in the control group. Corneal tomography as well as Ocular Response Analyzer measurements were compared between both groups. Subgroup analysis was performed with respect to the TKC staging. Asymmetry was provided as worse eye (defined by higher TKC) minus fellow eye. Results: In the KC group, both eyes showed the same TKC staging in 30.6%, a difference of one stage in 34.0% and of two stages in 24.6% of the patients. The inter-eye asymmetry in the keratoconus group was significantly larger than that in the control group. Corneal power showed an asymmetry of 3.8 ± 4.0 D in keratoconus eyes versus 0.22 ± 0.17 D in the control group. Central corneal thickness (CCT) asymmetry was 34 ± 30 µm versus 6 ± 5 µm, respectively. The Keratoconus Match Index showed an asymmetry of 0.40 ± 0.35 versus 0.15 ± 0.14. The difference between both eyes increased with increasing TKC of the worse eye. Conclusions: Inter-eye asymmetry is larger in keratoconus than in normal eyes, and it increases with keratoconus severity in the worse eye.