Imran Mahmood

Dr. Imran Mahmood


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2022 in Fractal and Fractional
Verified
Journal Article
Open access
PDF file
Muhammad Zia Ur RahmanMuhammad Zia Ur Rahman
Muhammad Zia Ur Rahman
Victor LeivaVictor Leiva
Victor Leiva
Carlos Martin-BarreiroCarlos Martin-Barreiro
Carlos Martin-Barreiro
IMImran Mahmood
Imran Mahmood
MUMuhammad Usman
Muhammad Usman
MRMohsin Rizwan
Mohsin Rizwan
Direct current (DC) servo motors are central to many complex systems, such as electrical, electro-mechanical, and electro-hydraulic frameworks. In practice, these systems can have nonlinear characteristics and parameter variations. Accurate model representation and position tracking of DC motors are the main issues in many real systems, such as twin rotors, aircraft, airships, and robot manipulators. The precise position tracking of these systems has already been achieved using conventional H-infinity (H∞) controllers. However, the order and structure become more intricate when employing complex weights to shape the closed-loop system, which limits the current proposals. To overcome the above-mentioned limitations, in this article, we provide a precise angular position tracking of a DC servo motor utilizing an intelligent, robust linear controller based on a fixed-structure linear fractional transformation. The conventional H∞ controllers are based on the minimization of an unstructured linear fractional transformation objective function that leads to a complex design of these controllers. The main advantage of the proposed intelligent H∞ synthesis is the fixed and simple structure that increases its practical implementation. The methodology is formulated in the MATLAB software for the robust design of the proposed synthesis based on an intelligent fixed-structure H∞ optimization. Simulation results are compared with conventional H∞ and proportional-integral-derivative controllers. The results are also validated experimentally.

31 May 2024 in Heliyon
Verified
Journal Article
Open access
HMHafiz Farhan Maqbool
Hafiz Farhan Maqbool
IMImran Mahmood
Imran Mahmood
AAAhmad Ali
Ahmad Ali
NINadeem Iqbal
Nadeem Iqbal
JSJin-Taek Seong
Jin-Taek Seong
Mohammed AwadMohammed Awad
Mohammed Awad
This study presents an analysis and evaluation of gait asymmetry (GA) based on the temporal gait parameters identified using a portable gait event detection system, placed on the lateral side of the shank of both lower extremities of the participants. Assessment of GA was carried out with seven control subjects (CS), one transfemoral amputee (TFA) and one transtibial amputee (TTA) while walking at different speeds on overground (OG) and treadmill (TM). Gait cycle duration (GCD), stance phase duration (SPD), swing phase duration (SwPD), and the sub-phases of the gait cycle (GC) such as Loading-Response (LR), Foot-Flat (FF), and Push-Off (PO), Swing-1 (SW-1) and Swing-2 (SW-2) were evaluated. The results revealed that GCD showed less asymmetry as compared to other temporal parameters in both groups. A significant difference (p < 0.05) was observed between the groups for SPD and SwPD with lower limb amputees (LLA) having a longer stance and shorter swing phase for their intact side compared to their amputated side, resulting, large GA for TFA compared to CS and TTA. The findings could potentially contribute towards a better understanding of gait characteristics in LLA and provide a guide in the design and control of lower limb prosthetics/orthotics.

21 May 2022 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
IMImran Mahmood
Imran Mahmood
ARAnam Raza
Anam Raza
HMHafiz Farhan Maqbool
Hafiz Farhan Maqbool
ADAbbas A. Dehghani-Sanij
Abbas A. Dehghani-Sanij

20 June 2024 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
IMImran Mahmood
Imran Mahmood
HMHafiz Farhan Maqbool
Hafiz Farhan Maqbool
ARAnam Raza
Anam Raza
NINadeem Iqbal
Nadeem Iqbal
ADAbbas A Dehghani-Sanij
Abbas A Dehghani-Sanij
A hip joint fracture includes a break in the thigh (femur) or coxa bone near the pelvis. During fracture healing, stability and weight bearing by the affected limb are key indicators to measure patients’ improvement. Conventionally, the rehabilitation effectiveness is monitored through clinical examinations, patients’ feedback, and few studies also reported instrumented gait evaluations. A gap remains there to numerically quantify the recovery in patients’ stability and weight bearing in response to rehabilitation therapies. This study introduces Nyquist and Bode (N&B) methods to analyse the instrumented gait signals further and evaluate gait stability in hip fracture patients during weight loading and unloading transitions. The centre of pressure (CoP) data was recorded using force plates for conditions: coxa hip fracture (HC), femur hip fracture (HF), and normal hip joint (NH). The time rate of CoP signals illustrated two major impulses during the loading and unloading phases which were modelled in time and frequency domains. The frequency models were further analysed by applying N&B methods and stability margins were computed for both impaired and healthy conditions. Results illustrated a significant decrease (Kruskal–Wallis’s test, p < 0.001) in the intralimb walking stability of both fracture conditions. Further, Spearman’s correlation between CoP velocities of fractured and intact limbs illustrated significant interlimb dependencies to maintain walking stability (p < 0.001) during weight loading and unloading transitions. Overall, the HF impairment illustrated the least intralimb walking stability and relatively greater interlimb dependencies. Clinically, these methods and findings are important to measure the recovery in patients undergoing rehabilitation after a hip joint or other lower limb impairments.

8 August 2024 in MethodsX
Verified
Journal Article
Open access
ARAnam Raza
Anam Raza
IMImran Mahmood
Imran Mahmood
TSTayyaba Sultana
Tayyaba Sultana
Lower limb fragility fractures require long-term rehabilitation and are also very expensive to treat. Clinically, early weight bearing and walking stability were reported as key measures of fracture restoration. This study introduces methods to numerically quantify these performance indices for a range of ankle and knee joint fractures. As a follow-up of initial treatment, experimental data was collected using force plates from 367 subjects divided into seven groups: ankle fracture (AF), lower leg ankle fracture (AL), calcaneus foot fracture (CF), knee tibia fracture (KF), knee patella fracture (KP), kneecap rupture (KR), and normal limb (NL). For each joint, data was analysed to evaluate intralimb and interlimb weight-bearing and walking stability for all fracture conditions. These thresholds were statistically compared with normal subjects. Some advantages of evaluating fracture restoration indices over the others include:•to quantify fracture restoration (weight-bearing, walking stability, and gait symmetry) using minimum setup and signal requirements.•to provide comprehensive tools to assess and overcome fracture-associated complications through a detailed preview of fractured limb functionality during subphases of a gait cycle.•in clinical research, such assessments are important as a reference to evaluate existing or new rehabilitative interventions.

26 October 2021 in Medical Engineering & Physics
Verified
Journal Article
Closed access
IMImran Mahmood
Imran Mahmood
ARAnam Raza
Anam Raza
ADAbbas A. Dehghani-Sanij
Abbas A. Dehghani-Sanij
Walking stability evaluation during gait transitional phases (loading and unloading) has been remained indistinct mainly due to methodological limitations and multiple biomechanical signals being used. This study introduces Nyquist and Bode methods using resultant neuromechanical output/input (O/I) responses to evaluate gait transitional stabilities. The centre of pressure and ground reaction force data are recorded experimentally as output and somatosensory input responses by the neuromotor. Six different walking conditions are simulated by wearing an adjustable orthosis using eleven healthy subjects. The rate of change in O/Is are modelled in time and frequency domains applying linear regression and stability margins are quantified applying N&B methods. Results from outputs showed loading phase as stable and unloading phase as unstable gait phases whereas the margins quantified from inputs showed unstable response during both phases. Stability margins quantified from outputs are decreased (p < 0.05) and instability margins are increased (p < 0.05) on applying ankle-foot restrictions. Overall, the neuromotor output stability margins are greater than the instabilities quantified from inputs. Furthermore, a strong interlimb negative correlation (p < 0.001) was found between loading and unloading phases computed from outputs. This study introduces new stability assessment methods with applications like evaluating lower limb impairments, varying terrains, and stability impacts of wearable devices.