Yungpil Yoo

Mr. Yungpil Yoo


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2024 in Entropy
Verified
Journal Article
Open access
PDF file
YYYungpil Yoo
Yungpil Yoo
SLSang Yup Lee
Sang Yup Lee
SSSeok-Ho Seo
Seok-Ho Seo
SOSi-doek Oh
Si-doek Oh
HKHo-Young Kwak
Ho-Young Kwak
Exergy analysis evaluates the efficiency of system components by quantifying the rate of entropy generation. In general, the exergy destruction rate or irreversibility rate was directly obtained through the exergy balance equation. However, this method cannot determine the origin of the component’s entropy generation rate, which is a very important factor in system design and improvement. In this study, a thorough energy, exergy, and thermoeconomic analysis of a proton-exchange membrane fuel cell (PEMFC) was performed, providing the heat transfer rate, entropy generation rate, and cost loss rate of each component. The irreversibility rate of each component was obtained by the Gouy–Stodola theorem. Detailed and extensive exergy and thermoeconomic analyses of the PEMFC system determined that water cooling units experience the greatest heat transfer among the components in the studied PEMFC system, resulting in the greatest irreversibility and, thus, the greatest monetary flow loss.

28 December 2023 in Entropy
Verified
Journal Article
Open access
PDF file
YYYungpil Yoo
Yungpil Yoo
HKHo-Young Kwak
Ho-Young Kwak
The maximum temperature limit at which liquid boils explosively is referred to as the superheat limit of liquid. Through various experimental studies on the superheating limit of liquids, rapid evaporation of liquids has been observed at the superheating limit. This study explored the water nucleation process at the superheat limit achieved in micro-platinum wires using a molecular interaction model. According to the molecular interaction model, the nucleation rate and time delay at 576.2 K are approximately 2.1 × 1011/(μm3μs) and 5.7 ns, respectively. With an evaporation rate (116.0 m/s) much faster than that of hydrocarbons (14.0 m/s), these readings show that explosive boiling or rapid phase transition from liquid to vapor can occur at the superheat limit of water. Subsequent bubble growth after bubble nucleation was also considered.

16 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
YYYungpil Yoo
Yungpil Yoo
SLSang Yup Lee
Sang Yup Lee
SSSeok-Ho Seo
Seok-Ho Seo
SOSi-doek Oh
Si-doek Oh
HKHo-Young Kwak
Ho-Young Kwak
Exergy analysis evaluates the efficiency of system components by quantifying the rate of entropy generation. In general, the exergy destruction rate or irreversibility rate was directly obtained through the exergy-balance equation. However, this method cannot determine the origin of the component's entropy generation rate, which is a very important factor in system design and improvement. In this study, a thorough energy, exergy thermoeconomic analysis of a proton exchange membrane fuel cell (PEMFC) was performed, providing the heat transfer rate, entropy generation rate and cost loss rate of each component. The irreversibility rate of each component is obtained by the Gouy-Stodolar theorem. Detailed and extensive exergy and thermoeconomic analyses of PEMFC system have determined that water cooling units experience the greatest heat transfer among the components in the studied PEMFC system, resulting in the greatest irreversibility and thus the greatest monetary flow loss.

8 October 2026 in Entropy
Verified
Journal Article
Open access
PDF file
YYYungpil Yoo
Yungpil Yoo
SSSeok-Ho Seo
Seok-Ho Seo
SOSi-doek Oh
Si-doek Oh
HKHo-Young Kwak
Ho-Young Kwak
Various exergy-based exergoeconomic methods have been developed to evaluate the production cost of electricity in power systems. One of the unresolved issues in the field of exergoeconomics is that different exergoeconomic analysis methods can yield different unit costs of power production. In this study, the unit cost of electricity generation is comprehensively analyzed using three representative approaches: the Moran method, the specific exergy costing (SPECO) method, and the Modified Productive Structure Analysis (MOPSA) method. The objective of this study is to identify a condition under which different exergoeconomic methods yield the same production cost for a power plant. The results show that power production costs are obtained using all three exergoeconomic methods when the costs associated with exergy destruction are appropriately incorporated in the cost-balance equation. In other words, under this condition, the cost-balance equations of SPECO and MOPSA for the entire power plant reduce to the Moran equation. These findings indicate that the critical issue in exergoeconomic analysis for determining the unit cost of products is whether the cost of exergy destruction is explicitly or implicitly accounted for. Furthermore, the numerical results demonstrate that all input cost rates, including equipment investment, operation and maintenance, and fuel costs, are fully recovered through the cost flow rates of the products. It is also shown that the cost flow associated with exergy destruction ultimately appears as the cost flow of waste streams.

30 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
YYYungpil Yoo
Yungpil Yoo
SSSeok-Ho Seo
Seok-Ho Seo
SOSi-doek Oh
Si-doek Oh
HKHo-Young Kwak
Ho-Young Kwak
Various exergy-based thermoeconomic methods have been developed to evaluate the production cost of electricity in power systems. One of the currently unresolved problems in the field of thermoeconomics is that different thermoeconomic analysis methods yield different unit power production costs. In this study, the unit cost of electricity generation is comprehensively analyzed using three representative approaches: the Moran method, the Specific Exergy Costing (SPECO) method, and the Modified Productive Structure Analysis (MOPSA) method. According to the results, similar power production costs are obtained across all thermoeconomic methods when the costs associated with exergy destruction are appropriately reflected in the cost-balance equation. In other words, in this case, the cost-balance equation for the entire power plant of SPECO and MOPSA becomes the Moran equation. These findings indicate that the critical issue in thermoeconomic analysis to obtain the unit cost of products is whether the cost of exergy destruction is explicitly or implicitly accounted for. Furthermore, the study numerically demonstrates that all input cost rates, including equipment investment, operation and maintenance, and fuel costs, are fully recovered through the cost flow rates of the products. It is also shown that the cost flow associated with exergy destruction ultimately appears as the cost flow of waste streams.