Si-doek Oh

Dr. Si-doek Oh

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 April 2022 in Energies
Verified
Journal Article
Open access
PDF file
SSSeok-Ho Seo
Seok-Ho Seo
SOSi-doek Oh
Si-doek Oh
HKHo-Young Kwak
Ho-Young Kwak
Thermodynamic, exergetic and thermoeconomic analyses were performed on two types of double-effect LiBr–water absorption refrigeration systems (ARS) for use with a 5-kW high-temperature proton exchange membrane fuel cell (HT-PEMFC) as a heat source. Proper temperatures of the high-pressure generator, combined generator and condenser, condenser, absorber and evaporator were determined to meet the requirements of constant cooling demands for data center operations. The heat balance of the combined unit of generator and condenser in the industrial double-effect LiBr-water ARS is important for determining the flow rate of the primary vapor refrigerant from the high-pressure generator. The industrial double-effect ARS system, whose analysis has not been studied analytically, outperformed the series double-effect system and provided 6.5 kW of cooling capacity with a coefficient of performance of 0.99. The unit cost of chilled water estimated by the modified productive structure analysis (MOPSA) method is approximately 7.18 USD/GJ (=0.026 US$/kWh). Effective exergetic efficiency of HT-PEMFC with the industrial ARS increases to 57.6% from 47.0%.

15 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
TKTaehun Kim
Taehun Kim
WLWon-Yong Lee
Won-Yong Lee
SSSeok-Ho Seo
Seok-Ho Seo
SOSi-doek Oh
Si-doek Oh
HKHo-Young Kwak
Ho-Young Kwak
The use of nuclear energy is inevitable to reduce the dependence on fossil fuels in the energy sector. High-temperature gas-cooled reactors (HTGRs) are considered as a system suitable for the purpose of reducing the use of fossil fuels. Furthermore, eco-friendly mass production of hydrogen is crucial because hydrogen is emerging as a next-generation energy carrier. The unit cost of hydrogen production by the levelized cost of energy (LCOE) method varies widely depending on the energy source and system configuration. In this study, energy, exergy, and thermoeconomic analyses were performed on the hydrogen production system using the HTGR and high-temperature water-cooled nuclear reactor (HTWR) to calculate reasonable unit cost of the hydrogen produced using a thermoeconomic method called modified production structure analysis (MOPSA). A flowsheet analysis was performed to confirm the energy conservation in each component. The electricity generated from the 600 MW HTGR system was used to produce 1.28 kmol/s of hydrogen by electrolysis to split hot water vapor. Meanwhile, 515 MW of heat from the 600 MW HTWR was used to produce 8.10 kmol/s of hydrogen through steam reforming, and 83.6 MW of electricity produced by the steam turbine was used for grid power. The estimated unit cost of hydrogen from HTGR is approximately USD 35.6/GJ with an initial investment cost of USD 2.6 billion. If the unit cost of natural gas is USD 10/GJ, and the carbon tax is USD 0.08/kg of carbon dioxide, the unit cost of hydrogen produced from HTWR is approximately USD 13.92/GJ with initial investment of USD 2.32 billion. The unit cost of the hydrogen produced in the scaled-down plant was also considered.

30 June 2024 in Entropy
Verified
Journal Article
Open access
PDF file
YYYungpil Yoo
Yungpil Yoo
SLSang Yup Lee
Sang Yup Lee
SSSeok-Ho Seo
Seok-Ho Seo
SOSi-doek Oh
Si-doek Oh
HKHo-Young Kwak
Ho-Young Kwak
Exergy analysis evaluates the efficiency of system components by quantifying the rate of entropy generation. In general, the exergy destruction rate or irreversibility rate was directly obtained through the exergy balance equation. However, this method cannot determine the origin of the component’s entropy generation rate, which is a very important factor in system design and improvement. In this study, a thorough energy, exergy, and thermoeconomic analysis of a proton-exchange membrane fuel cell (PEMFC) was performed, providing the heat transfer rate, entropy generation rate, and cost loss rate of each component. The irreversibility rate of each component was obtained by the Gouy–Stodola theorem. Detailed and extensive exergy and thermoeconomic analyses of the PEMFC system determined that water cooling units experience the greatest heat transfer among the components in the studied PEMFC system, resulting in the greatest irreversibility and, thus, the greatest monetary flow loss.

18 November 2022 in Energies
Verified
Journal Article
Open access
PDF file
KLKum-Jung Lee
Kum-Jung Lee
SSSeok-Ho Seo
Seok-Ho Seo
JCJunhyun Cho
Junhyun Cho
SOSi-doek Oh
Si-doek Oh
SCSang Ok Choi
Sang Ok Choi
HKHo-Young Kwak
Ho-Young Kwak
In this study, exergy and thermoeconomic analyses were performed on a Carnot battery system (CBS) comprising an air heat pump and steam turbine. The Carnot battery technology employed in this study stored electricity as heat for 10 h during night-time, when electricity prices were low, and generated electricity for 10 h with power output of 500 MW during the day, when electricity prices were relatively high. The roundtrip efficiency and the energy density of the CBS were approximately 0.37, and 150.0 MJ/m3, respectively. When the unit cost of electricity supplied to the heat pump system was approximately 23.0 USD/GJ, that of electricity produced by the steam turbine was approximately 70.8 USD/GJ. The thermoeconomic results indicate that the changes in electricity cost flow rate relative to the reference value can be used as an indicator to make purchasing, replacement, and research and development decisions for specific components of the CBS.

16 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
YYYungpil Yoo
Yungpil Yoo
SLSang Yup Lee
Sang Yup Lee
SSSeok-Ho Seo
Seok-Ho Seo
SOSi-doek Oh
Si-doek Oh
HKHo-Young Kwak
Ho-Young Kwak
Exergy analysis evaluates the efficiency of system components by quantifying the rate of entropy generation. In general, the exergy destruction rate or irreversibility rate was directly obtained through the exergy-balance equation. However, this method cannot determine the origin of the component's entropy generation rate, which is a very important factor in system design and improvement. In this study, a thorough energy, exergy thermoeconomic analysis of a proton exchange membrane fuel cell (PEMFC) was performed, providing the heat transfer rate, entropy generation rate and cost loss rate of each component. The irreversibility rate of each component is obtained by the Gouy-Stodolar theorem. Detailed and extensive exergy and thermoeconomic analyses of PEMFC system have determined that water cooling units experience the greatest heat transfer among the components in the studied PEMFC system, resulting in the greatest irreversibility and thus the greatest monetary flow loss.

30 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
YYYungpil Yoo
Yungpil Yoo
SSSeok-Ho Seo
Seok-Ho Seo
SOSi-doek Oh
Si-doek Oh
HKHo-Young Kwak
Ho-Young Kwak
Various exergy-based thermoeconomic methods have been developed to evaluate the production cost of electricity in power systems. One of the currently unresolved problems in the field of thermoeconomics is that different thermoeconomic analysis methods yield different unit power production costs. In this study, the unit cost of electricity generation is comprehensively analyzed using three representative approaches: the Moran method, the Specific Exergy Costing (SPECO) method, and the Modified Productive Structure Analysis (MOPSA) method. According to the results, similar power production costs are obtained across all thermoeconomic methods when the costs associated with exergy destruction are appropriately reflected in the cost-balance equation. In other words, in this case, the cost-balance equation for the entire power plant of SPECO and MOPSA becomes the Moran equation. These findings indicate that the critical issue in thermoeconomic analysis to obtain the unit cost of products is whether the cost of exergy destruction is explicitly or implicitly accounted for. Furthermore, the study numerically demonstrates that all input cost rates, including equipment investment, operation and maintenance, and fuel costs, are fully recovered through the cost flow rates of the products. It is also shown that the cost flow associated with exergy destruction ultimately appears as the cost flow of waste streams.