The occurrence of dampness and mold in the indoor environment is associated with respiratory-related disease outcomes. Thus, it is pertinent to know the magnitude of such indoor environment problems to be able to estimate the potential health impact in the population. In the present study, the moisture damage in 10,112 Norwegian dwellings was recorded based on building inspection reports. The levels of moisture damage were graded based on a condition class (CC), where CC0 is immaculate and CC1 acceptable (actions not required), while CC2 and CC3 indicate increased levels of damage that requires action. Of the 10,112 dwellings investigated, 3125 had verified moisture or mold damage. This amounts to 31% of the surveyed dwellings. Of these, 27% had CC2 as the worst grade, whereas 4% had CC3 as the worst grade level. The room types and building structures most prone to moisture damage were (in rank order) crawl spaces, basements, un-insulated attics, cooling rooms, and bathrooms. The high proportion of homes with moisture damage indicate a possible risk for respiratory diseases in a relatively large number of individuals, even if only the more extensive moisture damages and those located in rooms where occupants spend the majority of their time would have a significant influence on adverse health effects.
Displacement ventilation is a proven method of providing conditioned air to enclosed spaces with the aim to deliver good air quality and thermal comfort while reducing the amount of energy required to operate the system. Until now, the practical applications of displacement ventilation have been exclusive to providing ventilation and cooling to large open spaces with high ceilings. The provision of heating through displacement ventilation has traditionally been discouraged, out of concern that warm air supplied at the floor level would rise straight to the ceiling level without providing heat to the occupied space. Hence, a separate heating system is regularly integrated with the displacement ventilation in cold climates, increasing the cost and energy use of the system. This paper goes beyond the common industry practice and explores the possibility of using displacement ventilation to provide heating without any additional heating system. It reports on experimental investigations conducted in laboratory and field settings, and numerical simulation of these studies, all aimed at investigating the application of displacement ventilation for providing a comfortable indoor environment in winter by preheating the space prior to occupancy. The experimental results confirm that the proposed concept of providing space heating in unoccupied periods without a separate heating system is possible with displacement ventilation.
1 September 2019 in IOP Conference Series: Materials Science and Engineering
The aim of this study is to investigate whether children’s bioeffluent generation rate is proportional to their carbon dioxide (CO2) generation rate. Consequently, to assess if there is a need to differentiate the CO2- setpoint for different user groups, focusing on children. Perceived air quality (PAQ) and odour intensity (OI) were assessed in three classrooms in Oslo, Norway. Two second-grade classes (7-8 years old) were compared with one eighth-grade class (13-14 years old). An untrained test panel consisting of 16 people visited each classroom twice and were asked to evaluate PAQ and OI upon entering the classrooms. The CO2 levels in the classrooms were kept constant at either 600 ppm or 1100 ppm during each visitation. The results showed that average PAQ-score was significantly worse in the second-grade classrooms compared to the eighth-grade classroom. For perceived odour intensity, the average score indicated that the odour was stronger in the second-grade classrooms compared to the eighth-grade classroom, however, this difference in score was not significant. Our results indicate a need for differentiation of setpoints for CO2-DCV based on user groups, especially for children.