Pedro Emauel Rocha-Flores

Mr. Pedro Emauel Rocha-Flores

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2023 in Polymers
Verified
Journal Article
Open access
PDF file
CCChandani Chitrakar
Chandani Chitrakar
MTMarc Anthony Torres
Marc Anthony Torres
PRPedro Emauel Rocha-Flores
Pedro Emauel Rocha-Flores
QHQichan Hu
Qichan Hu
Melanie EckerMelanie Ecker
Melanie Ecker
Thiol-ene polymers are a promising class of biomaterials with a wide range of potential applications, including organs-on-a-chip, microfluidics, drug delivery, and wound healing. These polymers offer flexibility, softening, and shape memory properties. However, they often lack the inherent stretchability required for wearable or implantable devices. This study investigated the incorporation of di-acrylate chain extenders to improve the stretchability and conformability of those flexible thiol-ene polymers. Thiol-ene/acrylate polymers were synthesized using 1,3,5-triallyl-1,3,5-triazine-2,4,6(1H,3H,5H)-trione (TATATO), Trimethylolpropanetris (3-mercaptopropionate) (TMTMP), and Polyethylene Glycol Diacrylate (PEGDA) with different molecular weights (Mn 250 and Mn 575). Fourier Transform Infrared (FTIR) spectroscopy confirmed the complete reaction among the monomers. Uniaxial tensile testing demonstrated the softening and stretching capability of the polymers. The Young’s Modulus dropped from 1.12 GPa to 260 MPa upon adding 5 wt% PEGDA 575, indicating that the polymer softened. The Young’s Modulus was further reduced to 15 MPa under physiologic conditions. The fracture strain, a measure of stretchability, increased from 55% to 92% with the addition of 5 wt% PEGDA 575. A thermomechanical analysis further confirmed that PEGDA could be used to tune the polymer’s glass transition temperature (Tg). Moreover, our polymer exhibited shape memory properties. Our results suggested that thiol-ene/acrylate polymers are a promising new class of materials for biomedical applications requiring flexibility, stretchability, and shape memory properties.

4 December 2024 in Advanced Materials Technologies
Verified
Journal Article
Closed access
PRPedro Emauel Rocha-Flores
Pedro Emauel Rocha-Flores
CCChandani Chitrakar
Chandani Chitrakar
OROvidio Rodriguez‐Lopez
Ovidio Rodriguez‐Lopez
YRYao Ren
Yao Ren
Alexandra Joshi-ImreAlexandra Joshi-Imre
Alexandra Joshi-Imre
WVWalter E. Voit
Walter E. Voit

15 August 2023 in MRS Communications
Verified
Journal Article
Closed access
PDF file
PRPedro Emauel Rocha-Flores
Pedro Emauel Rocha-Flores
EGEdgar Guerrero
Edgar Guerrero
OROvidio Rodríguez-Lopez
Ovidio Rodríguez-Lopez
CCChandani Chitrakar
Chandani Chitrakar
APAnkit R. Parikh
Ankit R. Parikh
WVWalter E. Voit
Walter E. Voit

13 October 2021 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Open access
PDF file
YBYutika Badhe
Yutika Badhe
PRPedro Emauel Rocha-Flores
Pedro Emauel Rocha-Flores
WVWalter E. Voit
Walter E. Voit
DRDavid Remer
David Remer
LCLauren Costella
Lauren Costella
Alexandra Joshi-ImreAlexandra Joshi-Imre
Alexandra Joshi-Imre
Stretchable and flexible electronic applications require mechanically suitable electrical wiring. This article presents, for the first time, the microfabrication of photolithographically patterned microwiring on an electrospun nanofiber mat. The use of a photoresist-based technology allows for better than 10 μm pattern resolution on a good quality nanofiber mat, providing an order of magnitude smaller feature sizes than what has been published before. We demonstrate metallic wiring patterned from a 75 nm thick coating on top of the nanofiber mat. A silicone elastomer was incorporated to serve as a matrix material and form a composite substrate and an encapsulation layer on top of the microwiring. We demonstrate clean and anisotropic dry etching of the elastomer to open electrode sites that can be smaller than 10 μm in size. We speculate that these structures will be mechanically robust while being soft at the same time and provide the properties necessary for potential use in stretchable and flexible electronics.

11 September 2025 in bioRxiv
Verified
Preprint
Open access
APAndres Pascual-Leone
Andres Pascual-Leone
VTVishweshwar Tyagi
Vishweshwar Tyagi
AAAhmet S. Asan
Ahmet S. Asan
PRPedro Emauel Rocha-Flores
Pedro Emauel Rocha-Flores
OROvidio Rodriguez-Lopez
Ovidio Rodriguez-Lopez
JCJason B. Carmel
Jason B. Carmel
Target engagement determines therapeutic efficacy. In spinal cord stimulation (SCS), efficacy depends on the attributes of the electrodes used to deliver stimulation, particularly their position, interelectrode distance, size, and current orientation. We tested the effects of these electrode parameters using cervical stimulation to elicit forelimb muscle responses in the rat. We implanted devices over the C6 dorsal root entry zone (DREZ) in eight rats and measured responses in six forelimb muscles. We used custom designed electrode arrays to systematically vary position, distance, and size with linear arrays, and current orientation with circular arrays. Stimulation consisted of biphasic and pseudomonophasic pulse shapes with bipolar or distant return, and a high-definition montage with four returns surrounding a central contact to increase local current density. Efficacy was calculated from the motor thresholds of recruitment curves, and parameters were compared using linear mixed models. For position, stimulation over the DREZ was most effective, reducing thresholds by 25.9% ( p = 0.0002) relative to the midline; efficacy decreased as the electrode was positioned medial or lateral to the DREZ. For distance, placing the electrodes farther apart significantly improved efficacy ( p = 0.0022). For size, large electrodes increased SCS efficacy, reducing thresholds by 21.5% ( p = 0.0026) relative to small electrodes. After accounting for position and distance, current orientation did not affect SCS efficacy. Lastly, the high-definition montage decreased efficacy, increasing thresholds by 16.7% ( p = 0.003) relative to monopolar stimulation with a distant return. In conclusion, electrode position, distance, and size had the greatest effect on SCS efficacy, with the optimal parameters combining large electrodes at the DREZ position with a distant return. These results have the potential to lower the current needed to engage cervical spinal circuitry and to inform the design of SCS systems to improve dexterity in people with neurological injury or disease.