Melanie Ecker

Dr. Melanie Ecker

University of North Texas
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
QHQichan Hu
Qichan Hu
Melanie EckerMelanie Ecker
Melanie Ecker
Osteoarthritis (OA) is a common degenerative disease characterized by the destruction of articular cartilage and chronic inflammation of surrounding tissues. Matrix metalloproteinase-13 (MMP-13) is the primary MMP involved in cartilage degradation through its particular ability to cleave type II collagen. Hence, it is an attractive target for the treatment of OA. However, the detailed molecular mechanisms of OA initiation and progression remain elusive, and, currently, there are no interventions available to restore degraded cartilage. This review fully illustrates the involvement of MMP-13 in the initiation and progression of OA through the regulation of MMP-13 activity at the molecular and epigenetic levels, as well as the strategies that have been employed against MMP-13. The aim of this review is to identify MMP-13 as an attractive target for inhibitor development in the treatment of OA.

6 November 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MGMaria Alejandra Gonzalez Gonzalez
Maria Alejandra Gonzalez Gonzalez
AKAswini Kanneganti
Aswini Kanneganti
Alexandra Joshi-ImreAlexandra Joshi-Imre
Alexandra Joshi-Imre
AHAna G. Hernandez-Reynoso
Ana G. Hernandez-Reynoso
GBGeetanjali Bendale
Geetanjali Bendale
MRMario I. Romero-Ortega
Mario I. Romero-Ortega
Silicone nerve cuff electrodes are commonly implanted on relatively large and accessible somatic nerves as peripheral neural interfaces. While these cuff electrodes are soft (1–50 MPa), their self-closing mechanism requires of thick walls (200–600 µm), which in turn contribute to fibrotic tissue growth around and inside the device, compromising the neural interface. We report the use of thiol-ene/acrylate shape memory polymer (SMP) for the fabrication of thin film multi-electrode softening cuffs (MSC). We fabricated multi-size MSC with eight titanium nitride (TiN) electrodes ranging from 1.35 to 13.95 × 10−4 cm2 (1–3 kΩ) and eight smaller gold (Au) electrodes (3.3 × 10−5 cm2; 750 kΩ), that soften at physiological conditions to a modulus of 550 MPa. While the SMP material is not as soft as silicone, the flexural forces of the SMP cuff are about 70–700 times lower in the MSC devices due to the 30 μm thick film compared to the 600 μm thick walls of the silicone cuffs. We demonstrated the efficacy of the MSC to record neural signals from rat sciatic and pelvic nerves (1000 µm and 200 µm diameter, respectively), and the selective fascicular stimulation by current steering. When implanted side-by-side and histologically compared 30 days thereafter, the MSC devices showed significantly less inflammation, indicated by a 70–80% reduction in ED1 positive macrophages, and 54–56% less fibrotic vimentin immunoreactivity. Together, the data supports the use of MSC as compliant and adaptable technology for the interfacing of somatic and autonomic peripheral nerves.

10 February 2012 in Journal of Materials Chemistry
Verified
Journal Article
Closed access
PDF file
TPThorsten Pretsch
Thorsten Pretsch
Melanie EckerMelanie Ecker
Melanie Ecker
MSMarkus Schildhauer
Markus Schildhauer
MMMichael Maskos
Michael Maskos
Herein we demonstrate the realization of a new technological concept, which enables the use of shape memory polymers (SMPs) as switchable information carriers. At first, we applied a surface-specific dyeing process based on ‘guest-diffusion’ on two sophisticated polymeric host materials, including a thermoplastic poly(ester urethane) SMP and a thermoset epoxy-based SMP. Upon drying, self-assembly of the dye molecules inside the polymer surfaces occurred, resulting in homogeneous color penetration depths of about 100 μm. Subsequently, the colored surfaces were patterned with quick response (QR) codes. For this purpose, laser ablation was used. The resulting cavity depth was exceeding the color penetration depth. This assured sufficient surface contrast and rendered the QR codes machine-readable. In a progressive approach, two thermo-mechanical functionalization protocols were designed in accordance with the thermal properties of the polymers. As a result of programming, the tag prototypes were converted into stable, temporary shapes with non-decodable QR code information. When thermally triggering the shape memory effect on the functionalized tags, we verified the mostly complete recovery of the polymer surface and the associated restoration into the almost original shape. As such, the QR code could again precisely be read out. We anticipate that tagging products with these information carriers is helpful for the purpose of secure one-time identification.

9 January 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
ASAndrew J. Shoffstall
Andrew J. Shoffstall
SSSuraj Srinivasan
Suraj Srinivasan
MWMitchell Willis
Mitchell Willis
ASAllison Stiller
Allison Stiller
Melanie EckerMelanie Ecker
Melanie Ecker
JCJeffrey R. Capadona
Jeffrey R. Capadona
Mosquitos are among the deadliest insects on the planet due to their ability to transmit diseases like malaria through their bite. In order to bite, a mosquito must insert a set of micro-sized needles through the skin to reach vascular structures. The mosquito uses a combination of mechanisms including an insertion guide to enable it to bite and feed off of larger animals. Here, we report on a biomimetic strategy inspired by the mosquito insertion guide to enable the implantation of intracortical microelectrodes into the brain. Next generation microelectrode designs leveraging ultra-small dimensions and/or flexible materials offer the promise of increased performance, but present difficulties in reliable implantation. With the biomimetic guide in place, the rate of successful microprobe insertion increased from 37.5% to 100% due to the rise in the critical buckling force of the microprobes by 3.8-fold. The prototype guides presented here provide a reproducible method to augment the insertion of small, flexible devices into the brain. In the future, similar approaches may be considered and applied to the insertion of other difficult to implant medical devices.

23 February 2022 in Materials
Verified
Journal Article
Open access
PDF file
CCChandani Chitrakar
Chandani Chitrakar
EHEric Hedrick
Eric Hedrick
LALauren Adegoke
Lauren Adegoke
Melanie EckerMelanie Ecker
Melanie Ecker
Medical science technology has improved tremendously over the decades with the invention of robotic surgery, gene editing, immune therapy, etc. However, scientists are now recognizing the significance of ‘biological circuits’ i.e., bodily innate electrical systems for the healthy functioning of the body or for any disease conditions. Therefore, the current trend in the medical field is to understand the role of these biological circuits and exploit their advantages for therapeutic purposes. Bioelectronics, devised with these aims, work by resetting, stimulating, or blocking the electrical pathways. Bioelectronics are also used to monitor the biological cues to assess the homeostasis of the body. In a way, they bridge the gap between drug-based interventions and medical devices. With this in mind, scientists are now working towards developing flexible and stretchable miniaturized bioelectronics that can easily conform to the tissue topology, are non-toxic, elicit no immune reaction, and address the issues that drugs are unable to solve. Since the bioelectronic devices that come in contact with the body or body organs need to establish an unobstructed interface with the respective site, it is crucial that those bioelectronics are not only flexible but also stretchable for constant monitoring of the biological signals. Understanding the challenges of fabricating soft stretchable devices, we review several flexible and stretchable materials used as substrate, stretchable electrical conduits and encapsulation, design modifications for stretchability, fabrication techniques, methods of signal transmission and monitoring, and the power sources for these stretchable bioelectronics. Ultimately, these bioelectronic devices can be used for wide range of applications from skin bioelectronics and biosensing devices, to neural implants for diagnostic or therapeutic purposes.

16 December 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
AFAlex H. Fang
Alex H. Fang
WCWilson Chao
Wilson Chao
Melanie EckerMelanie Ecker
Melanie Ecker
Although surgeries involving anastomosis are relatively common, anastomotic leakages are potentially deadly complications of colorectal surgeries due to increased risk of morbidity and mortality. As a result of the potentially fatal effects of anastomotic leakages, a myriad of techniques and treatments have been developed to treat these unfortunate cases. In order to better understand the steps taken to treat this complication, we have created a composite review involving some of the current and best treatments for colonic anastomotic leakage that are available. The aim of this article is to present a background review of colonic anastomotic leakage, as well as current strategies to prevent and treat this condition, for a broader audience, including scientist, engineers, and especially biomedical engineers.