Ruimin Chen

Dr. Ruimin Chen

Research Center for Humanoid Sensing and Perception, Zhejiang Lab, Hangzhou 311121, China
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2012 in Nature Medicine
Verified
Journal Article
Closed access
PDF file
JYJoon-Mo Yang
Joon-Mo Yang
CFChristopher Favazza
Christopher Favazza
Ruimin ChenRuimin Chen
Ruimin Chen
JYJunjie Yao
Junjie Yao
XCXin Cai
Xin Cai
LWLihong V Wang
Lihong V Wang

2 March 2018 in Science Advances
Verified
Journal Article
Open access
PDF file
HHHongjie Hu
Hongjie Hu
XZXuan Zhu
Xuan Zhu
CWChonghe Wang
Chonghe Wang
LZLin Zhang
Lin Zhang
XLXiaoshi Li
Xiaoshi Li
Sheng XuSheng Xu
Sheng Xu
Ultrasound adds the third dimension to wearable sensors.

22 November 2018 in Nano Energy
Verified
Journal Article
Closed access
LJLaiming Jiang
Laiming Jiang
Yang YangYang Yang
Yang Yang
Ruimin ChenRuimin Chen
Ruimin Chen
GLGengxi Lu
Gengxi Lu
RLRunze Li
Runze Li
Qifa ZhouQifa Zhou
Qifa Zhou

9 November 2017 in Nature Communications
Verified
Journal Article
Open access
PDF file
Terence T. W. WongTerence T. W. Wong
Terence T. W. Wong
RZRuiying Zhang
Ruiying Zhang
CZChi Zhang
Chi Zhang
HHHsun-Chia Hsu
Hsun-Chia Hsu
KMKonstantin I. Maslov
Konstantin I. Maslov
LWLihong V. Wang
Lihong V. Wang
Three-dimensional (3D) optical imaging of whole biological organs with microscopic resolution has remained a challenge. Most versions of such imaging techniques require special preparation of the tissue specimen. Here we demonstrate microtomy-assisted photoacoustic microscopy (mPAM) of mouse brains and other organs, which automatically acquires serial distortion-free and registration-free images with endogenous absorption contrasts. Without tissue staining or clearing, mPAM generates micrometer-resolution 3D images of paraffin- or agarose-embedded whole organs with high fidelity, achieved by label-free simultaneous sensing of DNA/RNA, hemoglobins, and lipids. mPAM provides histology-like imaging of cell nuclei, blood vessels, axons, and other anatomical structures, enabling the application of histopathological interpretation at the organelle level to analyze a whole organ. Its deep tissue imaging capability leads to less sectioning, resulting in negligible sectioning artifact. mPAM offers a new way to better understand complex biological organs.

4 March 2015 in Optics Letters
Verified
Journal Article
Closed access
PDF file
BNBo Ning
Bo Ning
MKMatthew J. Kennedy
Matthew J. Kennedy
ADAdam J. Dixon
Adam J. Dixon
NSNaidi Sun
Naidi Sun
Rui CaoRui Cao
Rui Cao
SHSong Hu
Song Hu
Capitalizing on the optical absorption of hemoglobin, photoacoustic microscopy (PAM) is uniquely capable of anatomical and functional characterization of the intact microcirculation in vivo. However, PAM of the metabolic rate of oxygen (MRO2) at the microscopic level remains an unmet challenge, mainly due to the inability to simultaneously quantify microvascular diameter, oxygen saturation of hemoglobin (sO2), and blood flow at the same spatial scale. To fill this technical gap, we have developed a multi-parametric PAM platform. By analyzing both the sO2-encoded spectral dependence and the flow-induced temporal decorrelation of photoacoustic signals generated by the raster-scanned mouse ear vasculature, we demonstrated—for the first time—simultaneous wide-field PAM of all three parameters down to the capillary level in vivo.

4 October 2012 in Optics Express
Verified
Journal Article
Closed access
PDF file
JYJoon-Mo Yang
Joon-Mo Yang
Ruimin ChenRuimin Chen
Ruimin Chen
CFChristopher Favazza
Christopher Favazza
JYJunjie Yao
Junjie Yao
CLChiye Li
Chiye Li
LWLihong V. Wang
Lihong V. Wang
We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope’s instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications.