30 March 2015 in Nature Methods
23 April 2008 in Optics Letters
Capillaries, the smallest blood vessels, are the distal end of the vasculature where oxygen and nutrients are exchanged between blood and tissue. Hence, noninvasive imaging of capillaries and function in vivo has long been desired as a window to studying fundamental physiology, such as neurovascular coupling. Existing imaging modalities cannot provide the required sensitivity and spatial resolution. We present in vivo imaging of the microvasculature including single capillaries in mice using optical-resolution photoacoustic microscopy (OR-PAM) developed in our laboratory. OR-PAM provides a lateral resolution of and an imaging depth .
1 May 2017 in Nature Biomedical Engineering
15 June 2018 in Nature Communications
We have developed a single-breath-hold photoacoustic computed tomography (SBH-PACT) system to reveal detailed angiographic structures in human breasts. SBH-PACT features a deep penetration depth (4 cm in vivo) with high spatial and temporal resolutions (255 µm in-plane resolution and a 10 Hz 2D frame rate). By scanning the entire breast within a single breath hold (~15 s), a volumetric image can be acquired and subsequently reconstructed utilizing 3D back-projection with negligible breathing-induced motion artifacts. SBH-PACT clearly reveals tumors by observing higher blood vessel densities associated with tumors at high spatial resolution, showing early promise for high sensitivity in radiographically dense breasts. In addition to blood vessel imaging, the high imaging speed enables dynamic studies, such as photoacoustic elastography, which identifies tumors by showing less compliance. We imaged breast cancer patients with breast sizes ranging from B cup to DD cup, and skin pigmentations ranging from light to dark. SBH-PACT identified all the tumors without resorting to ionizing radiation or exogenous contrast, posing no health risks.
23 March 2011 in Optics Letters
We developed second-generation (G2) optical-resolution photoacoustic microscopy (OR-PAM). Incorporation of a novel acoustic detection scheme improved upon the sensitivity of our first-generation (G1) system by , deepening the in vivo tissue penetration to at . Moreover, translating the imaging head instead of the living object accelerated the scanning speed by a factor of 5, widening the field of view within the same acquisition time. Mouse ears, as well as mouse brains with intact craniums, were imaged in vivo in both total concentration and oxygen saturation of hemoglobin.
15 July 2012 in Nature Medicine