Zihan Yu

Dr. Zihan Yu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2023 in Fire
Verified
Journal Article
Open access
PDF file
LWLixin Wei
Lixin Wei
HTHonghui Tang
Honghui Tang
Jiaming ZhaoJiaming Zhao
Jiaming Zhao
CSChen Shiyi
Chen Shiyi
YXYiqiang Xie
Yiqiang Xie
ZYZihan Yu
Zihan Yu
To investigate the fire risk in a complex tunnel with varying cross-sections, sloped structures, and dense upper cover beams, this study considered four fire source positions: the immersed tube section, confluence section, highway auxiliary road section, and four-lane sections of the main line. It also considered four beam spacings: 1 m, 1.8 m, 3.6 m, and 7.2 m. The Fire Dynamics Simulation Software FDS was utilized to create a comprehensive tunnel model. The analysis focused on temperature and visibility changes at a 2 m height under a 20 MW fire condition for different fire source positions. These changes were then compared with critical danger values to assess the safety of evacuating personnel within the tunnel. Subsequently, this study proposed corresponding emergency rescue strategies. The findings indicated that when the beam grid spacing exceeded 3.6 m, the upper dense beam gap showed a robust smoke storage capacity, leading to a reduced distance of high-temperature smoke spread. However, this increased smoke storage disrupted the stability of the smoke layer, resulting in a heightened smoke thickness. The location of the ventilation vent at the entrance of the immersed tunnel section caused a non-uniform ventilation flow under the girder, deflecting the smoke front towards the unventilated side and decreasing visibility in the road auxiliary area. In comparison to scenarios without a beam lattice, the presence of a beam lattice in the tunnel amplified fire hazards. When the beam lattice spacing was 3.6 m or greater, the extent of the hazardous environment, which is unfavorable for personnel evacuation, expanded. With the exception of the scenario where the fire source was located in the highway auxiliary roadway, all other conditions surpassed 150 m, which is roughly one-third of the tunnel length. Consequently, more targeted strategies are necessary for effective evacuation and rescue efforts.

15 August 2025 in Mathematics
Verified
Journal Article
Open access
PDF file
ZYZihan Yu
Zihan Yu
ZXZhisheng Xu
Zhisheng Xu
ZWZuxian Wang
Zuxian Wang
YLYuexiang Lin
Yuexiang Lin
Accidental surface surcharge will generate additional load in the stratum, which then leads to unfavorable impacts on the underlying shield tunnel. This paper proposes a probabilistic analysis method to address this problem. In this framework, an improved soil–tunnel interaction model considering the nonlinearity of the subgrade is established at first, and the Newton–Raphson iterative solution algorithm is employed to acquire tunnel responses. Then, the random field models of the initial stiffness and the ultimate reaction of the subgrade are constructed to realize the spatial variability of soil properties. Finally, with the aid of the Monte Carlo Simulation method, the probabilistic analyses on tunnel responses are performed by combining the improved soil–tunnel interaction model and the random field model of subgrade parameters. The applicability and the superiority of the improved soil–tunnel interaction model are validated by a historical case from Shanghai Metro Line 9. The results prove that the traditional linear foundation model will overestimate the bearing capacity of the subgrade, thereby leading to overly optimistic assessments of surcharge-induced tunnel responses. This shortcoming could be addressed by the improved nonlinear soil–tunnel interaction model. The influences of spatial variability of soil properties on tunnel responses are nonnegligible. The stronger the uncertainties of subgrade parameters, in terms of the initial stiffness and the ultimate reaction concerned in this work, the higher the failure risk of the shield tunnel subjected to the surcharge. The failure modes of the tunnel subjected to the surcharge are controlled by the longitudinal curvature radius of the tunnel within the current assessment criteria, which means if this evaluation indicator can be restricted within the allowable value, then the opening of the circumferential joint and the longitudinal settlement can also meet the requirements. Compared with the influences of the uncertainty of the subgrade ultimate reaction, the spatial variability of the subgrade initial stiffness has greater influences on tunnel failure risk under the same conditions. An increase in the range of surcharge will raise the risk of tunnel failure, while the influence of tunnel burial depth is just the opposite.

29 September 2025 in Fire
Verified
Journal Article
Open access
PDF file
SFShilin Feng
Shilin Feng
LYLiang Yi
Liang Yi
ZXZhisheng Xu
Zhisheng Xu
ZYZihan Yu
Zihan Yu
Previous studies on tunnel fires have primarily focused on tunnels with flat ceilings and lacked studies on tunnels with beams. The present study is predicated on a reduced-scale tunnel model with a beam structure. Through meticulous analysis of the effects of factors such as longitudinal ventilation velocity and beam dimensions, the study unveils the distribution pattern of ceiling temperatures under the longitudinal smoke exhaust mode. The findings suggest that the presence of beams can induce turbulence in the longitudinal ventilation airflow. It has been demonstrated that the magnitude of this phenomenon is directly proportional to the spacing of the beams. This results in fluctuations in the ceiling temperature rise close to the combustion zone. The smoke storage capacity of the open cavities formed between adjacent beams is significantly affected by the beam height, thereby influencing the overall temperature rise beneath the ceiling. The greater the beam height, the higher the overall ceiling temperature rise near the combustion zone, but the lower the ceiling temperature rise downstream of the fire source. A prediction model for the longitudinal decay of ceiling temperature downstream of the fire source in tunnels with beams has been obtained. This model is related to the dimensionless beam dimension.