Chen Shiyi

Ms. Chen Shiyi


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2023 in Fire
Verified
Journal Article
Open access
PDF file
LWLixin Wei
Lixin Wei
HTHonghui Tang
Honghui Tang
Jiaming ZhaoJiaming Zhao
Jiaming Zhao
CSChen Shiyi
Chen Shiyi
YXYiqiang Xie
Yiqiang Xie
ZYZihan Yu
Zihan Yu
To investigate the fire risk in a complex tunnel with varying cross-sections, sloped structures, and dense upper cover beams, this study considered four fire source positions: the immersed tube section, confluence section, highway auxiliary road section, and four-lane sections of the main line. It also considered four beam spacings: 1 m, 1.8 m, 3.6 m, and 7.2 m. The Fire Dynamics Simulation Software FDS was utilized to create a comprehensive tunnel model. The analysis focused on temperature and visibility changes at a 2 m height under a 20 MW fire condition for different fire source positions. These changes were then compared with critical danger values to assess the safety of evacuating personnel within the tunnel. Subsequently, this study proposed corresponding emergency rescue strategies. The findings indicated that when the beam grid spacing exceeded 3.6 m, the upper dense beam gap showed a robust smoke storage capacity, leading to a reduced distance of high-temperature smoke spread. However, this increased smoke storage disrupted the stability of the smoke layer, resulting in a heightened smoke thickness. The location of the ventilation vent at the entrance of the immersed tunnel section caused a non-uniform ventilation flow under the girder, deflecting the smoke front towards the unventilated side and decreasing visibility in the road auxiliary area. In comparison to scenarios without a beam lattice, the presence of a beam lattice in the tunnel amplified fire hazards. When the beam lattice spacing was 3.6 m or greater, the extent of the hazardous environment, which is unfavorable for personnel evacuation, expanded. With the exception of the scenario where the fire source was located in the highway auxiliary roadway, all other conditions surpassed 150 m, which is roughly one-third of the tunnel length. Consequently, more targeted strategies are necessary for effective evacuation and rescue efforts.

3 July 2025 in Fire
Verified
Journal Article
Open access
PDF file
Jiaming ZhaoJiaming Zhao
Jiaming Zhao
CZCheng Zhang
Cheng Zhang
SFSaiya Feng
Saiya Feng
CSChen Shiyi
Chen Shiyi
GHGuanhong He
Guanhong He
WWWenbin Wei
Wenbin Wei
Metropolitan city express line tunnels are fully enclosed and often span long distances between stations, allowing multiple trains within a single interval. Traditional segmented ventilation ensures only one train per section, but ultra-long tunnels with shaftless designs introduce new challenges under fire conditions. This study investigates smoke behavior in an ultra-long inter-district tunnel during multi-train blockage scenarios. A numerical model evaluates the effects of train spacing, fire source location, and receding spacing on smoke back-layering, temperature distribution, and flow velocity. Results indicate that when train spacing exceeds 200 m and longitudinal wind speed is above 1.2 m/s, the impact of train spacing on smoke back-layering becomes negligible. Larger train spacing increases back-layering under constant wind speed, while higher wind speeds reduce it. Fire source location and evacuation spacing affect the extent and pattern of smoke spread and high-temperature zones, especially under reverse ventilation conditions. These findings provide quantitative insights into fire-induced smoke dynamics in ultra-long tunnels, offering theoretical support for optimizing ventilation control and evacuation strategies in urban express systems.