Rok Klobucar

Dr. Rok Klobucar

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
JSJakob Safaric
Jakob Safaric
RKRok Klobucar
Rok Klobucar
BABojan Acko
Bojan Acko
The rapid increase in precision of tactile coordinate measurement machines (CMMs) in recent years has caused an increased demand for high precision calibration artifacts, by which the traceability of coordinate measurements can be assured. This article presents research done in the development and verification of a high precision calibration system for step gauges, which are among the most frequently used CMM calibration artifacts. The main goals for the calibration system are measurement uncertainty of ${U}= ({{{(0.1}\,\,{{\mu m)}}}^{{2}}+{{(0.5\cdot }{{10}}^{{-6}} {\cdot L)}}^{{2}}})^{1/2} $ and full automatization of the measurement process, with human intervention only needed during the initial setup of the step gauge onto the system. Final verification has confirmed that both goals were achieved. The automation allows for autonomous measurement of the step gauge after the operator has performed the step gauge setup and entered nominal values of the measurement points, as well as the number of repetitions.

1 January 2019 in Measurement
Verified
Journal Article
Closed access
RKRok Klobucar
Rok Klobucar
MMMichael McCarthy
Michael McCarthy
BABojan Acko
Bojan Acko

10 March 2017 in Advances in Production Engineering & Management
Verified
Journal Article
Closed access
RKRok Klobucar
Rok Klobucar
BAB. Acko
B. Acko

9 October 2026 in Sensors
Verified
Journal Article
Open access
PDF file
LČLuka Čas
Luka Čas
BABojan Ačko
Bojan Ačko
RKRok Klobucar
Rok Klobucar
High-precision displacement transducers are widely used in dimensional metrology due to their sub-micron accuracy and broad applicability. The increasing use of such sensors has led to a growing demand for SI-traceable calibration, requiring high-accuracy systems beyond the capabilities of commercial solutions. This paper presents the development of a dedicated calibration system for displacement transducers with measuring ranges up to 150 mm and its experimental evaluation over a 60 mm measurement range. The system is based on commercially available components and employs a laser interferometer as the reference standard, enabling an absolute measurement principle with direct traceability to the primary length standard. The calibration set-up is fully automated and designed to minimize dominant sources of systematic errors, particularly geometric misalignments including transducer alignment, interferometer beam alignment and Abbe error. A structured calibration procedure and a comprehensive measurement uncertainty model are presented to ensure repeatable and traceable calibration. Experimental evaluation was performed using a high-resolution displacement transducer with 60 mm measurement range in both directions of motion. The results demonstrate the repeatability and performance of the developed system over the experimentally investigated 60 mm measurement range and are consistent with the proposed uncertainty model. Based on this model, the expanded measurement uncertainty of the proposed calibration system is estimated to be 130 nm (k = 2) for measurement ranges of up to 150 mm.