Hangfei Ye

Mr. Hangfei Ye

Beihang, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
HDHaifeng Dong
Haifeng Dong
HYHangfei Ye
Hangfei Ye
MHMin Hu
Min Hu
ZMZongmin Ma
Zongmin Ma
Optically pumped gradiometers have long been utilized in measurement in the International Geomagnetic Reference Field (IGRF). With advancements in technologies such as laser diodes and microfabrication, integrated gradiometers with compact sizes have become available, enabling improvements in magnetoencephalography and fetal magnetocardiography within shielded spaces. Moreover, there is a growing interest in the potential of achieving biomagnetic source detection without shielding. This review focuses on recent developments in optically pumped magnetic field gradiometers, including various fabrication methods and measurement schemes. The strengths and weaknesses of different types of optically pumped gradiometers are also analyzed.

1 May 2025 in Review of Scientific Instruments
Verified
Journal Article
Closed access
HYHangfei Ye
Hangfei Ye
CXChenlu Xu
Chenlu Xu
MHMin Hu
Min Hu
HDHaifeng Dong
Haifeng Dong
Optically pumped magnetic gradiometers (OPG) play a crucial role in applications such as magnetic anomaly detection and biomagnetic measurements. This study classifies current OPG into four types based on their differential modes: voltage, frequency, optical rotation, and magnetic field differential modes. We introduce the concept of inherent common mode rejection ratio (CMRR) and analyze the discrepancy between the inherent CMRR and the measured CMRR, as well as the upper limit of inherent CMRR. We point out that although the magnetic field differential method has the potential to increase the inherent CMRR by a factor of 1 + A(s)F(s), where A(s) and F(s) represent the forward and feedback channel complex gain, respectively, the often-overlooked difference between feedback gains between channels may impose a practical limit on the achievable inherent CMRR. We designed and fabricated a compact, unshielded OPG with a specially designed scheme to minimize the distance between the sensing head and the magnetic source. The measurement results demonstrate gradient sensitivity of 0.36 pT/cm/Hz with a CMRR of 8178@1 Hz in a shielded environment and 5 pT/cm/Hz with a CMRR of 1200@1 Hz in an unshielded environment.

25 April 2023 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
MHMin Hu
Min Hu
WJWeiming Jiang
Weiming Jiang
HYHangfei Ye
Hangfei Ye
HDHaifeng Dong
Haifeng Dong
YLYuanxing Liu
Yuanxing Liu
With the development of high spatial resolution spin image and magnetic field distribution measurement in atomic vapor cell, one can localize the position and calculate the magnetic moment of the field source around the cell. However, traditional cubic or spherical vapor cell can only measure the magnetic field distribution on one side of the field source, which limits the precision of the field inversion results. Here, we use a recessed atomic vapor cell to obtain field distribution around the source, which is positioned at the center of the cell. The magnetic field distributions around five sides of the field source are measured using movable stages and digital micro-mirror device. We combine the Levenberg–Marquardt algorithm with a genetic algorithm as the magnetic source localization algorithm to realize a quick global search as well as a precise local extreme point search. We obtain a spatial resolution of 219.2 × 387.0 × 451.5 μ m 3 and a magnetic field sensitivity of 0.06 nT / Hz 1 / 2 in a volume pixel of 0.0383 mm 3. The error in the localization of the magnetic source is 1.295 mm in the x direction, 185 μ m in the y direction, and 40 μ m in the z direction. The field distribution measurement method using recessed atomic vapor cell and related inversion algorithm demonstrated here have great potential applications in small scale field source detection of biology and materials science.

1 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CXChenlu Xu
Chenlu Xu
LWLizhen Wu
Lizhen Wu
JJJiayu Jiang
Jiayu Jiang
YDYangning Dai
Yangning Dai
HYHangfei Ye
Hangfei Ye
JCJiehua Chen
Jiehua Chen