Haifeng Dong

Dr. Haifeng Dong

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2016 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
HHHaichao Huang
Haichao Huang
HDHaifeng Dong
Haifeng Dong
LCLin Chen
Lin Chen
YGYang Gao
Yang Gao
A single-beam atomic magnetometer being operated near zero-field and measuring three-axis fields simultaneously is demonstrated. We produce a rotating field on the x-0-y plane with the frequency of 90 Hz and a modulation field in the z axis at 130 Hz. The rotating field enables a nonzero z axis output when the transverse fields are zeroed using feedback systems. Based on the phase difference of π/2 , x and y axes fields can be measured using one lock-in amplifier. Magnetic field sensitivities of 300 fT/Hz1∕2 in x and y axes and 3 pT/Hz1∕2 in the z axis are achieved.

11 July 2022 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
DXDongDong Xu
DongDong Xu
XWXiang Wang
Xiang Wang
YHYuanchao Hao
Yuanchao Hao
ZZZhun Zhang
Zhun Zhang
QHQiang Hao
Qiang Hao
LZLongbing Zhang
Longbing Zhang
As the Internet of Things (IoT) expands explosively existing network connections, the transmission and processing of private data is facing more serious threats of leakage and theft. Classical public key encryption schemes are difficult to guarantee strong security protection, because the mathematically hard problems they rely on are no longer difficult to solve under the rapid development of quantum computing. Therefore, a more high-performance and quantum-resistant encryption scheme Ring-ExpLWE is proposed, in which the error vector is sampled in the exponential distribution instead of the binary distribution in the previous Ring-BinLWE. We evaluate the Ring-ExpLWE’s security level by analyzing the runtime under quantum hybrid attack and comparing the standard deviation of the noise polynomial coefficients. Compared with Ring-BinLWE, the proposed Ring-ExpLWE requires larger runtime for quantum hybrid attack and has a more discrete noise distribution. Therefore, Ring-ExpLWE can provide a higher security level under the same parameter set. Moreover, the high-performance software and hardware implementations for the Ring-ExpLWE scheme are proposed, respectively. Based on the Cortex-M3 microprocessor platform, encryption, and decryption only require 35.6 and 17.8 ms in our software implementation, respectively. Compared with the previous Ring-BinLWE schemes, while significantly improving the security level, the Area $\times $ Time (AT) of our high-performance and lightweight hardware implementations is reduced by 49.2% and 49.5%, respectively, when the FPGA platform is Spartan 6.

13 September 2021 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
CLChen Liu
Chen Liu
HDHaifeng Dong
Haifeng Dong
JSJunjun Sang
Junjun Sang
Magnetic field source localization and imaging happen at different scales. The sensing baseline ranges from meter scale, such as magnetic anomaly detection, to centimeter scale, such as brain field imaging, to nanometer scale, such as the imaging of a magnetic skyrmion and single cell. Here, we show how an atomic vapor cell can be used to realize a baseline of 109.6 μm with a magnetic sensitivity of 10 pT/Hz1/2 @0.6–100 Hz and a dynamic range of 2062–4124 nT. We used a free induction decay (FID) scheme to suppress low-frequency noise and avoid scale factor variation for different domains due to light non-uniformity. The measurement domains are scanned by a digital micromirror device. The currents of 22, 30, 38, and 44 mA are applied in the coils to generate different fields along the pumping axis, which are measured respectively by fitting the FID signals of the probe light. The residual fields of every domain are obtained from the intercept of linearly fitting of the measurement data corresponding to these four currents. The coil-generated fields are calculated by deducting the residual fields from the total fields. The results demonstrate that the hole of shield affects both the residual and the coil-generated field distribution. The potential impact of field distribution measurement with outstanding comprehensive properties of spatial resolution, sensitivity, and dynamic range is far-reaching. It could lead to capability of 3D magnetography for small things and/or organs in millimeter or even smaller scale.

27 June 2019 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
HDHaifeng Dong
Haifeng Dong
JCJing-Ling Chen
Jing-Ling Chen
JLJi-Min Li
Ji-Min Li
CLChen Liu
Chen Liu
ALAi-Xian Li
Ai-Xian Li
FGFen-Zhuo Guo
Fen-Zhuo Guo
The diffusion crosstalk free distance is an important parameter for spin images in atomic vapor cells and is also regarded as a limit on the spatial resolution. However, by modulating the pumping light both spatially and temporally using a digital micromirror device, a spin image of a vapor cell has been obtained with a distinguishable stripe width of 13.7 μ m, which is much smaller than the corresponding diffusion crosstalk free distance of ∼ 138 μ m. The fundamental limit on the spatial resolution as determined by diffusion and the uncertainty principle is analyzed.

2 January 2019 in Electronics
Verified
Journal Article
Open access
PDF file
WWWeike Wang
Weike Wang
XZXiaobing Zhang
Xiaobing Zhang
QHQiang Hao
Qiang Hao
ZZZhun Zhang
Zhun Zhang
BXBin Xu
Bin Xu
XWXiang Wang
Xiang Wang
At present, the embedded systems are facing various kinds of attacks, especially for the data stored in the external memories. This paper presents a hardware-enhanced protection method to protect the data integrity and confidentiality at runtime, preventing the data from spoofing attack, splicing attack, replay attack, and some malicious analysis. For the integrity protection, the signature is calculated by the hardware implemented Lhash engine before the data sending off the chip, and the signature of the data block is recalculated and compared with the decrypted one at the load time. For the confidentiality protection, an AES encryption engine is used to generate the key stream, the plain data and the cipher data can translate through a simple XOR operation. The hardware cryptographic engines are optimized to work simultaneously with the memory access operation, which reduces the hardware overhead and the performance overhead. We implement the proposed architecture within OR1200 processor on Xilinx Virtex 5 FPGA platform. The experiment results show that the proposed hardware-enhanced protection method can preserve the integrity and confidentiality of the runtime data in the embedded systems with low power consumption and a marginal area footprint. The performance overhead is less than 2.27% according to the selected benchmarks.

27 December 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
HDHaifeng Dong
Haifeng Dong
HYHangfei Ye
Hangfei Ye
MHMin Hu
Min Hu
ZMZongmin Ma
Zongmin Ma
Optically pumped gradiometers have long been utilized in measurement in the International Geomagnetic Reference Field (IGRF). With advancements in technologies such as laser diodes and microfabrication, integrated gradiometers with compact sizes have become available, enabling improvements in magnetoencephalography and fetal magnetocardiography within shielded spaces. Moreover, there is a growing interest in the potential of achieving biomagnetic source detection without shielding. This review focuses on recent developments in optically pumped magnetic field gradiometers, including various fabrication methods and measurement schemes. The strengths and weaknesses of different types of optically pumped gradiometers are also analyzed.