The treatment of aortic aneurysms with endovascular stents or stent–graft prostheses is receiving increasing attention as an alternative to major abdominal surgery. To define the clinical value of this technique, we prospectively studied the use of stent–graft endoprostheses made of nitinol and covered with polyester fabric for the treatment of infrarenal abdominal aortic aneurysms.
The following changes have been made to the originally published version of this manuscript: A passage under the title “Indications for intervention” should read, “women with low BSA, TGFBR2 mutation, and severe extra-aortic features”, instead of “women with low BSA, patients with a TGFBR2 mutation, or patients with severe extra-aortic features that appear to be at particularly high risk”. Note ‘e’ from the legend for the table titled Recommendations on indications for surgery in (A) severe aortic regurgitation and (B) aortic root or tubular ascending aortic aneurysm (irrespective of the severity of aortic regurgitation) should read, “A lower threshold of 40 mm may be considered in women with low BSA” instead of “A lower threshold of 40 mm may be considered in women with low BSA, in patients with a TGFBR2 mutation or in patients with severe extra-aortic features”.
Aortic stenosis is a frequent valvular disease especially in elderly patients. Catheter-based valve implantation has emerged as a valuable treatment approach for these patients being either at very high risk for conventional surgery or even deemed inoperable. The German Aortic Valve Registry (GARY) provides data on conventional and catheter-based aortic procedures on an all-comers basis. A total of 13 860 consecutive patients undergoing repair for aortic valve disease [conventional surgery and transvascular (TV) or transapical (TA) catheter-based techniques] have been enrolled in this registry during 2011 and baseline, procedural, and outcome data have been acquired. The registry summarizes the results of 6523 conventional aortic valve replacements without (AVR) and 3464 with concomitant coronary bypass surgery (AVR + CABG) as well as 2695 TV AVI and 1181 TA interventions (TA AVI). Patients undergoing catheter-based techniques were significantly older and had higher risk profiles. The stroke rate was low in all groups with 1.3% (AVR), 1.9% (AVR + CABG), 1.7% (TV AVI), and 2.3% (TA AVI). The in-hospital mortality was 2.1% (AVR) and 4.5% (AVR + CABG) for patients undergoing conventional surgery, and 5.1% (TV AVI) and AVI 7.7% (TA AVI). The in-hospital outcome results of this registry show that conventional surgery yields excellent results in all risk groups and that catheter-based aortic valve replacements is an alternative to conventional surgery in high risk and elderly patients.
1 April 2008 in European Journal of Cardio-Thoracic Surgery
Outcomes after ventricular assist device (VAD) implantation have significantly improved during the last decade. However, bleeding episodes remain a serious complication of VAD support. This cannot be explained by the individual anticoagulation regimen alone in several cases, but may be symptomatic of acquired von Willebrand disease (VWD). The leading finding in acquired VWD (AVWD) is the loss of large multimers which results in diminished binding to collagen and to the platelets. We, therefore, analysed patients with two VAD types for laboratory parameters of VWD and compared them with patients after heart transplantation (HTX). Seven patients with a HeartMate II left-ventricular assist device and five patients who received a Thoratec biventricular assist device were included in this study. Eight HTX recipients served as controls. Analysis included international normalized ratio (INR), partial thromboplastin time (PTT), platelet count, von Willebrand factor (VWF) antigen, collagen binding capacity, ristocetin cofactor activity, the ratios of the latter two to the VWF antigen and presence of large VWF multimers. The VAD and HTX groups did not differ with regard to age or time-point of analysis after surgery. INR and number of platelets were comparable in both groups, PTT was prolonged in VAD patients. Both VAD and HTX patients had elevated but comparable amounts of VWF antigen. However, large multimers were missing in all of 10 tested VAD patients. In contrast, five of six tested HTX recipients displayed normal multimer pattern. Indeed, collagen binding capacity and ristocetin cofactor activity (which measures binding of VWF to platelets) were lower in VAD patients compared to HTX recipients. Impaired coagulation associated with VADs was also reflected by the diminished ratios of collagen binding capacity and ristocetin cofactor activity to VWF antigen. A pathologic collagen binding ratio was found in all 10 tested VAD patients and one of the eight HTX patients, a reduced ristocetin cofactor activity ratio in 10 of 12 VAD and one of eight HTX patients. Non-surgical postoperative bleeding after VAD implantation could be explained by an AVWD. Several pharmacologic treatment options (tranexamic acid, desmopressin, VWF-factor VIII concentrate, recombinant factor VIIa) may arise from our data. Improved VAD design could prevent this problem in the future.
13 November 2021 in New England Journal of Medicine
Tricuspid regurgitation is common in patients with severe degenerative mitral regurgitation. However, the evidence base is insufficient to inform a decision about whether to perform tricuspid-valve repair during mitral-valve surgery in patients who have moderate tricuspid regurgitation or less-than-moderate regurgitation with annular dilatation. We randomly assigned 401 patients who were undergoing mitral-valve surgery for degenerative mitral regurgitation to receive a procedure with or without tricuspid annuloplasty (TA). The primary 2-year end point was a composite of reoperation for tricuspid regurgitation, progression of tricuspid regurgitation by two grades from baseline or the presence of severe tricuspid regurgitation, or death. Patients who underwent mitral-valve surgery plus TA had fewer primary-end-point events than those who underwent mitral-valve surgery alone (3.9% vs. 10.2%) (relative risk, 0.37; 95% confidence interval [CI], 0.16 to 0.86; P=0.02). Two-year mortality was 3.2% in the surgery-plus-TA group and 4.5% in the surgery-alone group (relative risk, 0.69; 95% CI, 0.25 to 1.88). The 2-year prevalence of progression of tricuspid regurgitation was lower in the surgery-plus-TA group than in the surgery-alone group (0.6% vs. 6.1%; relative risk, 0.09; 95% CI, 0.01 to 0.69). The frequencies of major adverse cardiac and cerebrovascular events, functional status, and quality of life were similar in the two groups at 2 years, although the incidence of permanent pacemaker implantation was higher in the surgery-plus-TA group than in the surgery-alone group (14.1% vs. 2.5%; rate ratio, 5.75; 95% CI, 2.27 to 14.60). Among patients undergoing mitral-valve surgery, those who also received TA had a lower incidence of a primary-end-point event than those who underwent mitral-valve surgery alone at 2 years, a reduction that was driven by less frequent progression to severe tricuspid regurgitation. Tricuspid repair resulted in more frequent permanent pacemaker implantation. Whether reduced progression of tricuspid regurgitation results in long-term clinical benefit can be determined only with longer follow-up. (Funded by the National Heart, Lung, and Blood Institute and the German Center for Cardiovascular Research; ClinicalTrials.gov number, NCT02675244.)