: OBJECTIVES: Our goal was to evaluate results of endovascular aortic arch repair using the Relay Branch system. METHODS: Forty-three patients with thoracic aortic pathology involving the aortic arch have been treated with the Relay Branch system (Terumo Aortic, Sunrise, FL, USA) in 10 centres. We assessed in-hospital mortality, neurological injury, treatment success according to current reporting standards and the need for secondary interventions. In addition, outcome was analysed according to the underlying pathology: non-dissective disease versus residual aortic dissection (RAD) (defined as remaining dissection after previous type A repair, chronic type B aortic dissections). RESULTS: In-hospital mortality was 9% (0% in patients with RAD). Disabling stroke occurred in 7% (0% in patients with RAD); non-disabling stroke occurred in 19% (7% in patients with RAD). Early type IA and B endoleak formation occurred in 4%. Median follow-up was 16 ± 18 months. During the follow-up period, 23% of the patients died. Aortic-related deaths were low (3% in patients with RAD). CONCLUSIONS: The results of endovascular aortic arch repair using the Relay Branch system in a selected patient population with regard to technical success are good. In-hospital mortality is acceptable, the number of disabling strokes is low and technical success is high. Non-disabling stroke is a major concern, and every effort has to be taken to reduce this to a minimum. The best outcome is seen in patients with underlying RAD. Finally, more data are needed.
10 October 2020 in European Journal of Cardio-Thoracic Surgery
OBJECTIVES: The goal of this study was to evaluate outcomes of aortic arch replacement using the frozen elephant trunk (FET) technique after previous proximal and/or distal open or endovascular thoracic aortic repair. METHODS: Sixty-three patients [median age: 63 (55–74) years; 65% men] were operated on for acute or chronic aortic dissection after previous proximal and/or distal open or endovascular thoracic aortic repair. Intraoperative details, clinical outcome and follow-up results were evaluated. RESULTS: The median time between the index and the FET procedure was 81 (40–113) months. Fifty-eight (92%) patients had already undergone proximal aortic surgery; supracoronary ascending aortic replacement was the most frequent index procedure [n = 25 (40%)]. Distal aortic interventions had been done in 8 (13%) patients including endovascular thoracic aortic repair in 6 patients (10%). In-hospital mortality was 3% (n = 2). Postoperative strokes occurred in 5 patients (8%); of those, 1 stroke was dissection-related (2%). Subsequent aortic reinterventions after the FET procedure had to be done in 33% (n = 21). CONCLUSIONS: Outcomes of aortic arch replacement using the FET technique after previous proximal and/or distal open or endovascular thoracic aortic repair are associated with low mortality and morbidity. Still, postoperative stroke remains an issue. After the successful accomplishments, the approach serves as an ideal platform for the secondary surgical or endovascular downstream aortic procedures, which are frequently needed.
29 January 2022 in Interactive CardioVascular and Thoracic Surgery
This study aimed to analyse risk factors for postoperative stroke, evaluate the underlying mechanisms and report on outcomes of patients suffering a postoperative stroke after total aortic arch replacement using the frozen elephant trunk technique. Two-hundred and fifty patients underwent total aortic arch replacement via the frozen elephant trunk technique between March 2013 and November 2020 for acute and chronic aortic pathologies. Postoperative strokes were evaluated interdisciplinarily by a cardiac surgeon, neurologist and radiologist, and subclassified to each’s cerebral territory. We conducted a logistic regression analysis to identify any predictors for postoperative stroke. Overall in-hospital was mortality 10% (25 patients, 11 with a stroke). A symptomatic postoperative stroke occurred in 42 (16.8%) of our cohort. Eight thereof were non-disabling (3.3%), whereas 34 (13.6%) were disabling strokes. The most frequently affected region was the arteria cerebri media. Embolism was the primary underlying mechanism (n = 31; 73.8%). Mortality in patients with postoperative stroke was 26.2%. Logistic regression analysis revealed age over 75 (odds ratio = 3.25; 95% confidence interval 1.20–8.82; P = 0.021), a bovine arch (odds ratio = 4.96; 95% confidence interval 1.28–19.28; P = 0.021) and an acute preoperative neurological deficit (odds ratio = 19.82; 95% confidence interval 1.09–360.84; P = 0.044) as predictors for postoperative stroke. Stroke after total aortic arch replacement using the frozen elephant trunk technique remains problematic, and most lesions are of embolic origin. Refined organ protection strategies, and sophisticated monitoring are mandatory to reduce the incidence of postoperative stroke, particularly in older patients presenting an acute preoperative neurological deficit or bovine arch.
29 November 2021 in Interactive CardioVascular and Thoracic Surgery
OBJECTIVES: The aim of this study was to analyse outcomes of downstream thoracic endovascular aortic repair (TEVAR) following the frozen elephant trunk (FET) procedure. METHODS: Sixty-six patients underwent downstream TEVAR following the FET procedure to treat thoracic aortic dissections (n = 42, 64%), aneurysms (n = 19, 29%) or penetrating aortic ulcers involving the aortic arch (n = 5, 8%). Patient and outcome characteristics were analysed. RESULTS: Downstream TEVAR was performed 7 [interquartile range: 2–18] months after the FET procedure in 39 male (59%) and 27 female (41%) patients aged 68 [interquartile range: 56, 75] years, including 11 patients (17%) with a connective tissue disease. Before TEVAR, cerebrospinal fluid drainage was put in place in 61 patients (92%). Patients were treated with 1 stent graft (n = 28, 42%), 2 stent grafts (n = 37, 56%) or 3 stent grafts (n = 1, 2%). The femoral artery was accessed through surgical cut-down (n = 15, 23%) or percutaneously (n = 49, 74%). One patient (2%) developed a temporary spinal cord injury that resolved spontaneously. No case of permanent spinal cord injury, stroke or death was observed. After 12 [interquartile range: 2–23] months, 15 patients required an additional aortic reintervention (endovascular: n = 6; surgical: n = 9). CONCLUSIONS: Downstream TEVAR following the FET procedure is associated with excellent clinical outcomes. We thus maintain that staging thoracic aortic repair—FET and secondary TEVAR—is a very successful and safe strategy. Certain patients might need a tertiary procedure to fix their entire aortic pathology; therefore, they will require long-term continuous follow-up, ideally in a dedicated aortic clinic.
Our goal was to identify the inferior mesenteric artery diameter and number of patent lumbar arteries causing a significant type 2 endoleak to develop after infrarenal endovascular aneurysm repair. Included were patients who underwent infrarenal endovascular aneurysm repair between April 2002 and January 2017. Patients with an aneurysm involving the iliac arteries were excluded. Significant type 2 endoleak was defined as a type 2 endoleak observed after infrarenal endovascular aneurysm repair and accompanied by abdominal aneurysm growth of at least 5 mm during that time. A total of 277 patients were included. Mean follow-up was 38.9 (standard deviation 121.6) months. Immediately after infrarenal endovascular aneurysm repair, type 2 endoleaks occurred in 55 patients (20%), resolving spontaneously in 2 patients 6 months after infrarenal endovascular aneurysm repair. Thirty (10.8%) patients revealed a significant type 2 endoleak with aneurysm sack enlargement > 5 mm during follow-up, for which inferior mesenteric artery or lumbar artery coiling was performed. Mean time for coiling after primary infrarenal endovascular aneurysm repair was 25.4 (standard deviation 19.10) months. Twenty-three patients (8.3%) showed a non-significant type 2 endoleak during follow-up (no aneurysm sack enlargement). We found that the inferior mesenteric artery diameter and number of patent lumbar arteries were factors associated with a significant type 2 endoleak (odds ratio 1.755, P = 0.001; odds ratio 1.717, P < 0.001, respectively). Prior to endovascular aneurysm repair, the inferior mesenteric artery was patent in 212 (76.5%) patients; its median diameter measured 3 (0.5–3.8) mm. The median number of patent lumbar arteries was 3 (2–4). According to our receiver operating characteristic curve analysis, an inferior mesenteric artery diameter ≥3 mm (sensitivity 93.3%, specificity 65%) and ≥3 patent lumbar arteries (sensitivity 87.5%, specificity 43.6%) proved to be optimal cut-off values related to developing a significant type 2 endoleak. We therefore propose a composite score for the development of a significant type 2 endoleak [(inferior mesenteric artery diameter + patent lumbar arteries)/2]. Patients in whom the diameter of the inferior mesenteric artery is ≥ 3 mm and with ≥ 3 patent lumbar arteries carry a higher risk of developing significant type 2 endoleak after infrarenal endovascular aneurysm repair.