For people with respiratory disorders who need additional oxygen therapy, oxygen concentrators are vital medical equipment. By concentrating oxygen from the ambient air, they function to give the user a greater flow of oxygen-enriched air. The application of lithium zeolite for oxygen concentration in POCs is the most intense part of this work. One kind of zeolite material that may selectively absorb nitrogen from the air to increase oxygen concentration is lithium zeolite. The capacity, effectiveness, and dependability of a POC fitted with lithium zeolite are all examined in this study, along with its overall performance. The findings show that lithium zeolite, which has benefits including high oxygen purity and low energy consumption, is a potential material for use in POCs. The results of this study aid in the creation of POCs for oxygen therapy that are more effective and efficient. This study suggests utilizing an Arduino microcontroller and an HX710B air pressure sensor to measure the oxygen flow rate in a POC. The POC’s oxygen flow channel incorporates the HX710B sensor to monitor pressure variations, which the Arduino uses to translate into flow rate readings. To verify the accuracy and dependability of the system, its performance is assessed under different flow rate scenarios. Lithium zeolites are well-known for having a high selectivity for nitrogen adsorption, which can enhance the concentrator’s oxygen separation process’s effectiveness. Lithium-zeolite-based oxygen concentrators may have a lower environmental effect than standard concentrators.
This paper introduces the design and development of an intelligent, ultraportable oxygen concentrator weighing around 5.5 kg with closed-loop automation for optimal oxygen delivery. The system is Pressure Swing Adsorption (PSA) technology-based with a MAX30100 sensor for continuous monitoring of peripheral oxygen saturation (SpO₂) to modulate oxygen flow in real-time based on patient needs. Oxygen flow rate is managed by a DC motor-driven mechanism, combined with a stepper motor, and backed by force-torque analysis. A Proportional-Integral-Derivative (PID) control algorithm is used to control compressor speed, dynamically adjusting to sensor inputs to maintain desired oxygen purity levels. System validation using a PO 80 Pulse Oximeter ensured accurate tracking of SpO₂ and heart rate. Experimental results indicate improved energy efficiency, low response time, and customized oxygen therapy and demonstrate the appropriateness of the system for clinical and portable applications. The compressor and flow regulation valve, driven by a DC motor and stepper motor, respectively, respond to the controller outputs, with torque and pressure feedback ensuring stable flow rate and enhancing system reliability. PID controller gains were optimized using the Ziegler-Nichols method and iterative refinement to achieve optimum settling time and overshoot, while ensuring overall system stability and patient safety. Statistical analysis was used to evaluate system performance and reliability. A one-way analysis of variance (ANOVA) was used to determine significant differences between the significant parameters SpO₂ levels, response time, flow rate, and energy consumption among three oxygen delivery modes: intelligent control, fixed flow, and manual titration. Follow-up pair-wise t-tests established specific group differences, of which confidence intervals provided estimates of measurement precision. The statistical technique offers strong evidence for the better performance of the intelligent control system.
This study presents the design and development of a portable oxygen concentrator prototype with IoT-enabled monitoring and automated oxygen-flow regulation based on measured physiological parameters. An ESP32 microcontroller processes data and handles wireless communication, while a MAX30102 sensor measures peripheral oxygen saturation (SpO 2 ) and heart rate for system monitoring and control. The developed prototype provides oxygen flow rates ranging from 1 to 5 LPM, with oxygen purity measured between 90.68 ± 0.084% and 93.34 ± 0.114% across the tested flow conditions. The corresponding outlet pressure ranged from 1.150 ± 0.007 to 1.200 ± 0.007 bar, while stabilization time increased from 32.0 ± 0.707 to 46.0 ± 0.707 s. Power consumption increased from 142 to 150 W as the flow rate increased from 1 to 5 LPM. Each operating condition was evaluated using five experimental repetitions. In automatic mode, the closed-loop controller adjusts the oxygen-flow setting according to variations in the measured SpO 2 level. The system achieved a local control latency of 42.0 ± 3.0 ms, a ThingSpeak communication latency of 195.0 ± 8.0 ms, and a total end-to-end latency of 237.0 ± 7.0 ms. The acquired measurements were displayed locally through an OLED interface and transmitted to the ThingSpeak cloud platform for remote monitoring. The developed system is a bench-tested research prototype, and the reported results are limited to laboratory-level evaluation. The findings demonstrate the feasibility of integrating physiological sensing, automated flow regulation, and IoT-based monitoring within a portable oxygen-concentrator prototype; however, clinical validation and long-term reliability assessment are required before any medical or patient-specific application can be established.
Chronic obstructive pulmonary disease results from a collection of lung illnesses that restrict airflow, causing breathing difficulty. Pulmonary fibrosis result from scarring of the lung tissue that causes difficulty breathing,Emphysema is a lung illness that causes the destruction of the lungs air sacs in the lungs. Oxygen concentrator can assist Chronic obstructive pulmonary disease patients in staying active and enhancing their quality of life. Oxygen concentrators are medical devices that extract from ambient air and deliver it to patients requiring supplemental oxygen therapy. Monitoring and optimizing their performance is crucial for ensuring patient safety and delivery of the correct amount of oxygen. Air pressure sensors play a vital role in this process by providing data on various aspects of the Portable Oxygen concentrator's operation Flow rate, pressure, purity of portable oxygen concentrator. The purpose of this study is to evaluate the feasibility of employing an oxygen concentrator as a platform to measure airflow with airflow sensors. By incorporating airflow sensors into an oxygen concentrator system, a non-intrusive and cost-effective approach for monitoring airflow in a variety of environments,including medical, environmental, and industrial can be developed. To investigate the feasibility of employing an Arduino Uno microcontroller and an air pressure sensor to monitor the oxygen flow rate and purity in an oxygen concentrator in order to optimize its performance. Portable oxygen concentrators are medical devices that supply extra oxygen to people who have low blood oxygen levels. These devices are smaller and lighter than fixed oxygen concentrators are, making them perfect for those who must be mobile. Portable oxygen concentrators are an extremely useful tool for individual with low blood oxygen levels. They can help people remain active, improve their quality of life, and lessen their need for oxygen tanks. A portable oxygen Concentrator with pressure swing adsorption and HX710B air pressure sensor for health monitoring has been constructed.