Currently, fixed-parameter proportional–integral–derivative (PID) control is widely adopted by the governor of hydropower units (HPUs), which causes regulation performance to deteriorate during variable operating conditions. To solve this problem, a novel particle swarm optimization-based fuzzy PID (PSO-FPID) is proposed for the frequency regulation of HPUs. The segment linearization model of HPU is first established to reflect the changes in the operating conditions. On this basis, FPID is designed based on expert experience. The PID control parameters are optimized using PSO under different operating conditions to determine the optimal initial values of the FPID controller. To verify the effectiveness of the proposed PSO-FPID, its performance is compared and analyzed with the actual PID, FPID, and particle swarm optimization-based PID (PSO-PID) in the MATLAB/Simulink platform. The results show that the average adjust time of PSO-FPID is 16.60 s less than that of PID, 18.05 s less than that of FPID, and 0.23 s less than that of PSO-PID. PSO-FPID can maintain better control performance than the other methods under most operating conditions.
The use of renewable energy has become a necessity to generate electricity, and is taking the place of conventional coal-fired power, as it has clear economic and environmental benefits. The purpose of this paper is to quantify the comprehensive benefits of hydropower in reducing wind power fluctuation in a hybrid coal-fired/hydro/wind power system. To achieve this, a wind–hydropower generation system must be established, and its complementary characteristic is also illustrated based on the resultant wind speed. Then, based on Institute of Electrical and Electronics Engineers (IEEE) 14 Bus Power System, coal-fired generation is introduced to model a final hybrid integrated power system. The comprehensive benefit evaluation method, including the power consumption profit, the peak load profit, the energy conservation profit, the guide vane fatigue cost, the maintenance cost, and the start-stop cost, is presented to assess the join operation benefits of the wind/hydropower/coal-fired integrated system. The complementary investigation shows that the hydropower system has an excellent effect on suppressing wind power fluctuation, although the fatigue damage of hydraulic guide vanes is a little severe for the time scale of hours, compared with that of seconds. The quantified benefit shows that the increased power consumption profit, the increased guide vane fatigue loss cost, the decreased peak-load profit, and the increased energy conservation profit are RMB 1262.43 million/year, RMB 0.37 million/year, RMB 333.97 million/year and RMB 0.54 million/year, with the wind and hydropower ratio increasing from 16% to 25%, which directly leads to the annual total revenue increasing to RMB 143.2673 million. The implementation of this paper can contribute to making more efficient use of wind-hydro power in conventional electricity production.
Renewable energy generation technology, as an alternative to traditional coal-fired power generation, is receiving increasing attention. However, the intermittent characteristics of wind and solar energy pose certain challenges to the stable operation of power grids. This requires a better understanding of the operational characteristics of renewable energy to improve the comprehensive efficiency. To achieve this, firstly, four indicators (i.e., average fluctuation magnitude, Richards–Baker flashiness, average climbing rate, and change in the time-averaged value) within a single-evaluation-indicator framework are proposed to quantitatively evaluate the fluctuation characteristics of wind, solar, and hydropower and a wind–solar–hydro hybrid power system. Secondly, a comprehensive evaluation indicator is developed by scientifically assigning and recombining the four indicators using entropy weight theory. Furthermore, the comprehensive evaluation index is applied to the wind–solar–hydro hybrid power system to determine the operational characteristics of subsystems and a complementary system at different time scales. Finally, the load tracking coefficient and coupling degree are used to quantify the complementarity degree of the hybrid power system. It is found that the fluctuation degree of the hybrid power system is smaller than that of the individual power system. Meanwhile, both fluctuation and complementary characteristics are strengthened with the increase in time scale. The proposed methods and results shift the volatility from an abstract concept to concrete representation, providing a new perspective and reference for evaluating the operational characteristics of the hybrid power system to achieve power system planning and scheduling.
A parameter sensitivity analysis is an important part of the stability study of hydro turbine regulation systems, which helps operators to deepen their understanding of the characteristics and connections among the various parts of these systems. Considering that large hydropower stations undertake an essential regulation task in the power grid, the safety and stability of their operation cannot be ignored. To this end, taking a unit in a giant hydropower station in China as an example, a hydraulic–mechanical–electrical coupling model of the hydraulic turbine regulation system is established. A comprehensive parameter sensitivity indicator and parameter sensitivity analysis framework are proposed. On this basis, the sensitivity of the main system variables to parameter changes under full operating conditions is investigated by considering two different control modes of the unit (i.e., corresponding to different grid types). The results show that the sensitivity of the system state to the mechanical parameters of the generator is the highest in the power control mode, while the sensitivity to the electrical parameters of the generator and excitation system is higher in the frequency control mode. The sensitivity of the system with these key parameters also shows different patterns of change with a change in the unit operating conditions. The relevant findings can provide some theoretical guidance for the operation of hydropower stations and help to reduce the risk of system instability.
The integration of new energy into the grid has significantly intensified power grid operational pressure, posing higher demands on hydropower system regulation. As a key unit for power grid load tracking and stability maintenance, parameter mismatch of the PID governor is prone to inducing system bifurcation, thus leading to oscillatory instability, which has emerged as a critical challenge affecting the reliable consumption and sustainable supply of new energy. To address this challenge, a hydroelectric power generation system (HPGS) model in the infinite-bus power system is established. Bifurcation analysis is employed to quantitatively identify the critical thresholds of PID parameters that cause HPGS instability. Based on this, system dynamic response processes under critical thresholds are clarified using time-domain analysis. Furthermore, the potential oscillation instability mechanism is revealed using eigenvalue analysis, and suggestions for PID parameter selection are provided. Key quantitative results indicate that variations in proportional gain, kp, induce five limit point bifurcations. The system enters an unstable region when kp exceeds 2.467, whereas operation within the range below 0.891 is conducive to system stability. A supercritical Hopf bifurcation arises when integral gain ki reaches 0.925, so strict restrictions should be imposed on ki to avoid operating around this critical value. Two supercritical Hopf bifurcations that may trigger system oscillatory instability are identified during differential gain kd changing, and it should be regulated to a level below 5.188 to ensure system stability. By integrating bifurcation analysis, time-domain analysis, and eigenvalue analysis, this study effectively improves the accuracy of characterizing system dynamic behaviors, providing a clear quantitative basis for PID parameter optimization and bifurcation suppression, as well as laying a theoretical foundation for hydropower system stable operation and the efficient absorption of new energy.