In the coming decades, the proportion of wind–solar energy in power system significantly increases, resulting to uncertainties of power fluctuation in abundant wind–solar energy regions. The flexibility operation of Pumped Storage Power Plants (PSPPs) has already been widely recognized to regulate wind–solar power fluctuations; however, less is known about the regulation reliability of the PSPP affected by them. It is a challenge, since various uncertainties exist during this regulation process. Here, a mathematical model with a solar–wind–hydro hybrid power generation system is adopted to investigate the regulation reliability of PSPP. The uncertainties and limitations of model parameters are considered during this process. Five regulation indexes, i.e., rise time, settling time, peak value, peak time and overshoot of the reactive power generator terminal voltage, guide vane opening and angular velocity, are extracted to evaluate the PSSP’s regulation quality. Finally, the PSPP reliability probability affected by parametric uncertainties is presented. The obtained results show that the inertia coefficient is the most sensitivity parameters for the settling time, peak value and peak time with sensitivity index 33.7%, 72.55% and 71.59%, respectively. The corresponding total contribution rate of the top 10 sensitive parameters are 74.45%, 93.45% and 87.15%, respectively. Despite some types of uncertainties not being considered, the results of this research are important for the regulation reliability evaluation of PSPPs in suppressing power fluctuations of wind and solar generation.
13 May 2019 in Journal of Computational and Nonlinear Dynamics
Forces and moments increase rapidly in complex interactions while maintaining stability of the shaft for the hydroelectric generating system in the load rejection process. These interactions caused by factors such as the unbalanced hydraulic fault give rise to vibration patterns, which are of interest for fault identification and diagnosis. In this work, the vibration characteristics of the generating system are investigated in the load rejection process. The first is a novel-established model based on the interaction effect of the mechanical–electrical forces and the pressure pulsation solved by method of characteristics in the penstock. In the second analysis, the shaft displacement is compared with experimental data in order to verify the correctness of the established model. Transient radial displacements are conducted in different load rejection conditions and then mechanical and electrical factors are analyzed to investigate the shaft vibration characteristics. The results of this study suggest that the excretion coefficient of the runner inlet, the initial position angle of the turbine blade, the up guide bearing, and the mass of the generator rotor have the ability in decreasing the shaft vibration, while decreasing the mass eccentricity reduces the shaft vibration and ensure the structural reliability of the generating system.
The penetration of multiple integrated renewable energies to the power grid are relevant for decision making in energy policy, environment and business. Such an electricity penetration is affected by the intermittent and volatile characteristics of integrated energies, mostly significantly related to the safe and stable electricity production and supply in real world. Here, this paper focuses on the low frequency oscillation analysis of the hydropower generation response to the wind and solar variability. To enable this analysis, a hybrid model of hydropower system integrating with the wind and solar power system is presented. The Nyquist and root-locus stability methods are used to investigate the sensitivity performance of the hydropower governor to the fluctuation of the integrated renewable energies. Additionally, to quantify the risk of the hybrid system, the low frequency oscillation response of hydropower system to wind/solar/hydropower quota and transmission line distance ratio is extensively investigated in this study. The results show that under the case of the wind, solar and hydropower ratio is 40:1:150, the optimal values for maximally reducing hydropower low frequency oscillation are finally determined as kp = 0.8, ki = 0.25 and kd = 0.5. Regarding a certain wind/solar/hydropower quota, it is a promising strategy to increase the solar-load transmission line in order to achieve the safe and stable operation of the hybrid system and a relatively excellent dynamic regulation capacity of the hydropower governor. The model, methods and results implemented in this study are exploited to markedly improve new knowledge applications, policy management, low carbon emissions and investment competitiveness of future energy systems.
This paper focuses on the implementation of a Hamiltonian model of multi-unit hydropower systems (MUHSs). First, a nonlinear mathematical model of the MUHS is established considering the occurrence of water hammer during the transient process. From the point of view of the energy transmission and dissipation of the system, a novel Hamiltonian model of the MUHS is proposed. Moreover, numerical simulations are carried out to further investigate the effectiveness and consistency of the implemented model. Finally, a comparative analysis is performed to validate the proposed approach against existing methods. The results demonstrate that the proposed Hamiltonian function not only reflects the energy change but also describes the complex dynamic evolution of MUHSs in transient processes. It is also found that the transient dynamic behavior of the system is influenced by the coupled effect of common penstock and the interaction of basic system variables. This study provides theoretical basis for the safe and stable operation of hydropower stations during transient processes.
The use of renewable energy has become a necessity to generate electricity, and is taking the place of conventional coal-fired power, as it has clear economic and environmental benefits. The purpose of this paper is to quantify the comprehensive benefits of hydropower in reducing wind power fluctuation in a hybrid coal-fired/hydro/wind power system. To achieve this, a wind–hydropower generation system must be established, and its complementary characteristic is also illustrated based on the resultant wind speed. Then, based on Institute of Electrical and Electronics Engineers (IEEE) 14 Bus Power System, coal-fired generation is introduced to model a final hybrid integrated power system. The comprehensive benefit evaluation method, including the power consumption profit, the peak load profit, the energy conservation profit, the guide vane fatigue cost, the maintenance cost, and the start-stop cost, is presented to assess the join operation benefits of the wind/hydropower/coal-fired integrated system. The complementary investigation shows that the hydropower system has an excellent effect on suppressing wind power fluctuation, although the fatigue damage of hydraulic guide vanes is a little severe for the time scale of hours, compared with that of seconds. The quantified benefit shows that the increased power consumption profit, the increased guide vane fatigue loss cost, the decreased peak-load profit, and the increased energy conservation profit are RMB 1262.43 million/year, RMB 0.37 million/year, RMB 333.97 million/year and RMB 0.54 million/year, with the wind and hydropower ratio increasing from 16% to 25%, which directly leads to the annual total revenue increasing to RMB 143.2673 million. The implementation of this paper can contribute to making more efficient use of wind-hydro power in conventional electricity production.