Lauro Ojeda

Mr. Lauro Ojeda

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2006 in Journal of Field Robotics
Verified
Journal Article
Closed access
PDF file
LOLauro Ojeda
Lauro Ojeda
JBJohann Borenstein
Johann Borenstein
GWGary Witus
Gary Witus
RKRobert Karlsen
Robert Karlsen

1 September 2007
Verified
Conference Paper
Closed access
LOLauro Ojeda
Lauro Ojeda
JBJohann Borenstein
Johann Borenstein
This paper introduces a positioning system for walking persons, called "Personal Dead-reckoning" (PDR) system. The PDR system does not require GPS, beacons, or landmarks. The system is therefore useful in GPS-denied environments, such as inside buildings, tunnels, or dense forests. Potential users of the system are military and security personnel as well as emergency responders. The PDR system uses a 6-DOF inertial measurement unit (IMU) attached to the user's boot. The IMU provides rate-of-rotation and acceleration measurements that are used in real-time to estimate the location of the user relative to a known starting point. In order to reduce the most significant errors of this IMU-based system-caused by the bias drift of the accelerometers-we implemented a technique known as "Zero Velocity Update" (ZUPT). With the ZUPT technique and related signal processing algorithms, typical errors of our system are about 2% of distance traveled for short walks. This typical PDR system error is largely independent of the gait or speed of the user. When walking continuously for several minutes, the error increases gradually beyond 2%. The PDR system works in both 2-dimensional (2-D) and 3-D environments, although errors in Z-direction are usually larger than 2% of distance traveled. Earlier versions of our system used an unpractically large IMU. In the most recent version we implemented a much smaller IMU. This paper discussed specific problems of this small IMU, our measures for eliminating these problems, and our first experimental results with the small IMU under different conditions.

7 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
MPMichael Potter
Michael Potter
LOLauro Ojeda
Lauro Ojeda
Noel PerkinsNoel Perkins
Noel Perkins
SCStephen Cain
Stephen Cain
Researchers employ foot-mounted inertial measurement units (IMUs) to estimate the three-dimensional trajectory of the feet as well as a rich array of gait parameters. However, the accuracy of those estimates depends critically on the limitations of the accelerometers and angular velocity gyros embedded in the IMU design. In this study, we reveal the effects of accelerometer range, gyro range, and sampling frequency on gait parameters (e.g., distance traveled, stride length, and stride angle) estimated using the zero-velocity update (ZUPT) method. The novelty and contribution of this work are that it: (1) quantifies these effects at mean speeds commensurate with competitive distance running (up to 6.4 m/s); (2) identifies the root causes of inaccurate foot trajectory estimates obtained from the ZUPT method; and (3) offers important engineering recommendations for selecting accurate IMUs for studying human running. The results demonstrate that the accuracy of the estimated gait parameters generally degrades with increased mean running speed and with decreased accelerometer range, gyro range, and sampling frequency. In particular, the saturation of the accelerometer and/or gyro induced during running for some IMU designs may render those designs highly inaccurate for estimating gait parameters.

15 December 2019 in Journal of Field Robotics
Verified
Journal Article
Closed access
PDF file
MQMichael Quann
Michael Quann
LOLauro Ojeda
Lauro Ojeda
WSWilliam Smith
William Smith
DRDenise Rizzo
Denise Rizzo
MCMatthew Castanier
Matthew Castanier
KBKira Barton
Kira Barton

1 May 2004 in Autonomous Robots
Verified
Journal Article
Closed access
PDF file
LOLauro Ojeda
Lauro Ojeda
JBJohann Borenstein
Johann Borenstein

27 August 2017 in Sensors
Verified
Journal Article
Open access
PDF file
RVRachel Vitali
Rachel Vitali
SCStephen Cain
Stephen Cain
Ryan McginnisRyan Mcginnis
Ryan Mcginnis
AZAntonia Zaferiou
Antonia Zaferiou
LOLauro Ojeda
Lauro Ojeda
Noel PerkinsNoel Perkins
Noel Perkins
Three-dimensional rotations across the human knee serve as important markers of knee health and performance in multiple contexts including human mobility, worker safety and health, athletic performance, and warfighter performance. While knee rotations can be estimated using optical motion capture, that method is largely limited to the laboratory and small capture volumes. These limitations may be overcome by deploying wearable inertial measurement units (IMUs). The objective of this study is to present a new IMU-based method for estimating 3D knee rotations and to benchmark the accuracy of the results using an instrumented mechanical linkage. The method employs data from shank- and thigh-mounted IMUs and a vector constraint for the medial-lateral axis of the knee during periods when the knee joint functions predominantly as a hinge. The method is carefully validated using data from high precision optical encoders in a mechanism that replicates 3D knee rotations spanning (1) pure flexion/extension, (2) pure internal/external rotation, (3) pure abduction/adduction, and (4) combinations of all three rotations. Regardless of the movement type, the IMU-derived estimates of 3D knee rotations replicate the truth data with high confidence (RMS error < 4 ° and correlation coefficient r ≥ 0.94 ).