Tjundewo Lawu

Tjundewo Lawu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
TLTjundewo Lawu
Tjundewo Lawu
KMKoichiro Mukai
Koichiro Mukai
HMHiroyuki Matsushima
Hiroyuki Matsushima
TSTadashi Senoo
Tadashi Senoo
To compare the effect of decentration and tilt on the optical performance of 6 aspheric intraocular lens (IOL) designs in a model eye. Department of Ophthalmology, Graduate School of Medicine, Dokkyo Medical University, Tochigi, Japan. Experimental study. In theoretical simulations, the amount of spherical aberration in the IOL was varied to produce residual ocular spherical aberration (range -0.15 to 0.30 μm) at a 6.0 mm entrance pupil. Wavefront aberration analyses were performed with the ZEMAX optical design program (version August 20, 2014) to obtain the ocular root-mean-square values of astigmatism, coma, trefoil, and higher-order aberrations (HOAs) when the IOL was centered on the insertion position and misaligned at a 4.0 mm entrance pupil. The retinal visual images were calculated using the same conditions. Six 20.0 diopter (D) aspheric IOLs and one 20.0 D spherical IOL were used for the experimental studies. Each IOL was inserted in the model eye. The actual alignments were measured using a Scheimpflug camera (EAS-1000). The wavefront aberrations and visual images were gauged using a wavefront analyzer (KR-1W) at several IOL alignments. Intraocular lens decentration and tilt increased wavefront aberrations and degraded optical performance. Astigmatism, coma, and HOAs generated by misaligned IOLs were related to the amount of spherical aberration correction of the IOLs. The extent of spherical aberration remained unchanged by the amount of misalignment. Experimental model eye results showed trends similar to theoretical results. The spherical aberration correction amount in the aspheric IOL design was critical for the astigmatism, coma, and HOAs generated by the IOL misalignment. Additional spherical aberration corrections led to a more sensitive optical performance degradation resulting from IOL misalignment.

1 June 2022 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
SGSo Goto
So Goto
NMNaoyuki Maeda
Naoyuki Maeda
KOKazuhiko Ohnuma
Kazuhiko Ohnuma
TLTjundewo Lawu
Tjundewo Lawu
RKRyo Kawasaki
Ryo Kawasaki
TNToru Noda
Toru Noda
Purpose: To evaluate the performance of a new formula of intraocular lens (IOL) power calculation (the O formula) based on ray tracing without commonly used parameters, including ultrasound-compatible axial length, keratometry readings, and A-constant. Setting: Tokyo Medical Center, Tokyo, Japan. Design: Retrospective consecutive case series. Methods: 423 eyes (423 patients) implanted with a single-piece, L-loop, acrylic IOL were enrolled. All biometric data for the O formula were obtained by anterior segment swept-source optical coherence tomography (SS-OCT) and SS-OCT–based biometer. The performance of the O formula was compared with those of the Barrett Universal II (BUII) and Kane formulas at 1 month postoperatively. Statistical analysis was applied according to a heteroscedastic test with SD of prediction errors as the main parameter for formula performance. Results: The SD of the O formula (0.426) was statistically significantly lower than that of the BUII formula (0.464, P = .034) but not statistically significantly different from that of the Kane formula (0.433, P = .601). The percentages of patients with refractive prediction errors within ±0.50 diopter (D) and ±1.00 D of the O, BUII, and Kane formulas were 75.4% and 98.6%, 77.1% and 97.9%, and 76.6% and 98.1%, respectively. Conclusions: The O formula, based on ray tracing using SS-OCT–based devices, is one of the promising approaches for IOL power calculation, although additional larger scale studies are needed. It may be used as an alternative in IOL power calculation because of its independence from commonly used parameters.

7 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SGSo Goto
So Goto
NMNaoyuki Maeda
Naoyuki Maeda
KUKota Uehara
Kota Uehara
KOKeiko Ogawa
Keiko Ogawa
MMMaki Matsumaru
Maki Matsumaru
TNToru Noda
Toru Noda
Purpose: To evaluate the performance of traditional vergence formulas with segmented axial length (AL) compared to traditional composite AL in extremely long eyes, and to determine whether the segmented AL can be extended to the new-generation formulas, including the Barrett Universal II, Emmetropia Verifying Optical 2.0 (EVO2), Hill-RBF 3.0 (Hill3), Kane, and Ladas Super formula (LSF) formulas in extremely long eyes. Setting: National Hospital. Organization, Tokyo Medical Center, Japan. Design: Retrospective case series. Methods: Consecutive patients who underwent uncomplicated cataract surgery implanted with a three-piece intraocular lens between December 2015 and March 2021 were retrospectively reviewed. The composite AL was measured with a swept-source optical coherence tomography (SS-OCT) biometer using a mean refractive index. The segmented AL was calculated by summing the geometric lengths of the ocular segments (cornea, aqueous, lens, and vitreous) using multiple specific refractive indices based on the data obtained by the SS-OCT-based biometer. When refraction was measured at three months postoperatively, the median absolute errors (MedAEs) were calculated with two ALs for each formula. Results: The study included 31 eyes of 22 patients. The segmented AL (30.45 ± 1.23 mm) was significantly shorter than the composite AL (30.71 ± 1.28 mm, p < 0.001). The MedAEs were significantly reduced when using segmented AL for SRK/T, Haigis, Hill3, and LSF, compared to those obtained using composite AL (0.38 vs. 0.62, 0.48 vs. 0.79, 0.50 vs. 0.90, 0.34 vs. 0.61, p < 0.001 for all formulas, respectively). On the contrary, the MedAE obtained by Kane with segmented AL was significantly worse compared to the one with composite AL (0.35 vs. 0.27, p = 0.03). Conclusion: In extremely high myopic eyes, the segmented AL improves the performance of SRK/T, Haigis, Hill3, and LSF formulas compared to the composite AL, while the segmented AL worsens the prediction accuracy of the Kane formula.

24 August 2025 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
PDF file
YSYuki Shiraishi
Yuki Shiraishi
ECEnchi K Chang
Enchi K Chang
YYYukari Yagi-Yaguchi
Yukari Yagi-Yaguchi
YKYuma Kayama
Yuma Kayama
YKYuki Kusano
Yuki Kusano
Takefumi YamaguchiTakefumi Yamaguchi
Takefumi Yamaguchi
Aim The purpose of this study is to investigate the accuracy of intraocular lens (IOL) power calculation after penetrating keratoplasty (PK) or deep anterior lamellar keratoplasty (DALK) and to identify the causes of predictive errors (PEs) in relation to the subjective keratometric (K) value (SK) in eyes with corneal multifocality. Methods This retrospective study included 74 eyes that underwent cataract surgery after PK or DALK. PEs were compared between SRK/T, Haigis, Barrett Universal II (BUII) and Kane formulas. In 27 eyes with postoperative anterior segment optical coherence tomography (AS-OCT) data, SKs were calculated based on postoperative refraction, IOL position, IOL power and axial length using Zemax. This was compared with K values obtained using AS-OCT. Results Mean absolute PE was 1.50±1.60 dioptre in SRK/T, 1.96±1.80 in Haigis, 1.84±1.71 in BUII and 1.83±1.86 in Kane. SK was significantly correlated with true K (TK) (r=0.86, p<0.001). The difference between SK and TK showed a significant correlation with PE in SRK/T (r=0.53, p=0.001). The PE in SRK/T was modelled as a function of the change in preoperative and postoperative K values as well as the difference between TK and SK, with significant improvement in the PE after factoring in these parameters. Conclusions Multifocal corneas, such as those after PK or DALK, may have SK values that differ significantly from K values obtained from AS-OCT. Therefore, traditional IOL formulas that use standard K values may lead to a refractive surprise after cataract surgery.