Toru Noda

Toru Noda

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 September 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TOTetsuro Oshika
Tetsuro Oshika
HAHiroyuki Arai
Hiroyuki Arai
YFYoshifumi Fujita
Yoshifumi Fujita
MIMikio Inamura
Mikio Inamura
YIYasushi Inoue
Yasushi Inoue
KMKazunori Miyata
Kazunori Miyata
We conducted a one-year prospective, multicenter study to assess clinical outcomes after implantation of segmented, rotationally asymmetric multifocal intraocular lenses (IOLs) with +1.5 diopters (D) near addition. In this phase III clinical trial, 120 eyes of 65 patients undergoing phacoemulsification and implantation of Lentis Comfort LS-313 MF15 (Oculentis GmbH) were included. The ophthalmological examinations were performed before and 1 day, 1 week, 1, 3, 6, 9, and 12 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were measured. A defocus curve was obtained and patients were asked about the severity of photic phenomena. Postoperative distance and intermediate visual acuity was excellent, with UDVA, CDVA, UIVA, and DCIVA of approximately 20/20, 20/16, 20/25, 20/25 were attained, respectively. The level of near visual acuity was lower; UNVA and DCNVA remained at around 20/60 and 20/70, respectively. The defocus curve indicated that postoperative uncorrected visual acuity of 20/25 and 20/40 was obtained at as close as 67 cm and 50 cm, respectively. Contrast sensitivity was within the normal range, with a minimal level of subjective symptoms and high patient satisfaction. The rotationally asymmetric multifocal IOLs with +1.5 D near addition provided excellent distance and intermediate vision, but near vision was not enough for reading small prints. Contrast sensitivity was high, with very low incidences of photic phenomena and a high level of patient satisfaction.

1 June 2022 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
SGSo Goto
So Goto
NMNaoyuki Maeda
Naoyuki Maeda
KOKazuhiko Ohnuma
Kazuhiko Ohnuma
TLTjundewo Lawu
Tjundewo Lawu
RKRyo Kawasaki
Ryo Kawasaki
TNToru Noda
Toru Noda
Purpose: To evaluate the performance of a new formula of intraocular lens (IOL) power calculation (the O formula) based on ray tracing without commonly used parameters, including ultrasound-compatible axial length, keratometry readings, and A-constant. Setting: Tokyo Medical Center, Tokyo, Japan. Design: Retrospective consecutive case series. Methods: 423 eyes (423 patients) implanted with a single-piece, L-loop, acrylic IOL were enrolled. All biometric data for the O formula were obtained by anterior segment swept-source optical coherence tomography (SS-OCT) and SS-OCT–based biometer. The performance of the O formula was compared with those of the Barrett Universal II (BUII) and Kane formulas at 1 month postoperatively. Statistical analysis was applied according to a heteroscedastic test with SD of prediction errors as the main parameter for formula performance. Results: The SD of the O formula (0.426) was statistically significantly lower than that of the BUII formula (0.464, P = .034) but not statistically significantly different from that of the Kane formula (0.433, P = .601). The percentages of patients with refractive prediction errors within ±0.50 diopter (D) and ±1.00 D of the O, BUII, and Kane formulas were 75.4% and 98.6%, 77.1% and 97.9%, and 76.6% and 98.1%, respectively. Conclusions: The O formula, based on ray tracing using SS-OCT–based devices, is one of the promising approaches for IOL power calculation, although additional larger scale studies are needed. It may be used as an alternative in IOL power calculation because of its independence from commonly used parameters.

1 May 2024 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
SGSo Goto
So Goto
NMNaoyuki Maeda
Naoyuki Maeda
.O.Kazuhiko Ohnuma
.Kazuhiko Ohnuma
TLTjundewo Lawu
Tjundewo Lawu
KOKeiko Co Ogawa
Keiko Co Ogawa
TNToru Noda
Toru Noda
Purpose: To investigate the difference between the segmented axial length (AL) and the composite AL on a swept-source optical coherence tomography biometer and to evaluate the subsequent effects on artificial intelligence intraocular lens (IOL) power calculations: the Kane and Hill-RBF 3.0 formulas compared with established vergence formulas. Setting: National Hospital Organization, Tokyo Medical Center, Japan. Design: Retrospective case series. Methods: Consecutive patients undergoing cataract surgery with a single-piece IOL were reviewed. The prediction accuracy of the Barrett Universal II, Haigis, Hill-RBF 3.0, Hoffer Q, Holladay 1, Kane, and SRK/T formulas based on 2 ALs were compared for each formula. The heteroscedastic test was used with the SD of prediction errors as the endpoint for formula performance. Results: The study included 145 eyes of 145 patients. The segmented AL (24.83 ± 1.89) was significantly shorter than the composite AL (24.88 ± 1.96, P < .001). Bland-Altman analysis revealed a negative proportional bias for the differences between the segmented AL and the composite AL. The SD values obtained by Hoffer Q, Holladay 1, and SRK/T formulas based on the segmented AL (0.52 diopters [D], 0.54 D, and 0.50 D, respectively) were significantly lower than those based on the composite AL (0.57 D, 0.60 D, and 0.52 D, respectively, P < .01). Conclusions: The segmented ALs were longer in short eyes and shorter in long eyes than the composite ALs. The refractive accuracy can be improved in the Hoffer Q, Holladay 1, and SRK/T formulas by changing the composite ALs to the segmented ALs.

30 December 2020 in Retina
Verified
Journal Article
Open access
KAKunihiko Akiyama
Kunihiko Akiyama
KFKaoru Fujinami
Kaoru Fujinami
KWKen Watanabe
Ken Watanabe
TMTakaaki Matsuki
Takaaki Matsuki
KTKazushige Tsunoda
Kazushige Tsunoda
TNToru Noda
Toru Noda
Purpose: To assess the validity of retinal surface wrinkling (RSW) as an indicator to select patients relevant for internal limiting membrane peeling during vitrectomy for rhegmatogenous retinal detachment, to prevent postoperative visual decline due to epiretinal membrane growth. Methods: This was a prospective, interventional case series of 78 consecutive eyes that underwent initial vitrectomy to repair rhegmatogenous retinal detachments and were followed for 6 months. The presence/absence of RSW was evaluated presurgically on en face optical coherence tomographic images. The internal limiting membrane was peeled if RSW was identified. The main outcome measure was the prevalence of postsurgical epiretinal membrane growth that caused a visual decline of 0.2 or more in logarithm of the minimum angle of resolution unit. Results: The internal limiting membrane was peeled for RSW appearance in 22 eyes (28.2%). Mild epiretinal membranes developed in 8 of the 56 internal limiting membrane–unpeeled eyes (10.3% of total, 6 eyes at stage 1 in the classification of Govetto); however, visual decline occurred in none of them with the mean visual acuity of these 8 eyes maintained at −0.08 ± 0.11 in logarithm of the minimum angle of resolution (≈20/16). Conclusion: Visual decline due to epiretinal membrane growth after rhegmatogenous retinal detachment repair was entirely prevented by peeling the internal limiting membrane in about 30% of cases selected for the presence of RSW.

7 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SGSo Goto
So Goto
NMNaoyuki Maeda
Naoyuki Maeda
KUKota Uehara
Kota Uehara
KOKeiko Ogawa
Keiko Ogawa
MMMaki Matsumaru
Maki Matsumaru
TNToru Noda
Toru Noda
Purpose: To evaluate the performance of traditional vergence formulas with segmented axial length (AL) compared to traditional composite AL in extremely long eyes, and to determine whether the segmented AL can be extended to the new-generation formulas, including the Barrett Universal II, Emmetropia Verifying Optical 2.0 (EVO2), Hill-RBF 3.0 (Hill3), Kane, and Ladas Super formula (LSF) formulas in extremely long eyes. Setting: National Hospital. Organization, Tokyo Medical Center, Japan. Design: Retrospective case series. Methods: Consecutive patients who underwent uncomplicated cataract surgery implanted with a three-piece intraocular lens between December 2015 and March 2021 were retrospectively reviewed. The composite AL was measured with a swept-source optical coherence tomography (SS-OCT) biometer using a mean refractive index. The segmented AL was calculated by summing the geometric lengths of the ocular segments (cornea, aqueous, lens, and vitreous) using multiple specific refractive indices based on the data obtained by the SS-OCT-based biometer. When refraction was measured at three months postoperatively, the median absolute errors (MedAEs) were calculated with two ALs for each formula. Results: The study included 31 eyes of 22 patients. The segmented AL (30.45 ± 1.23 mm) was significantly shorter than the composite AL (30.71 ± 1.28 mm, p < 0.001). The MedAEs were significantly reduced when using segmented AL for SRK/T, Haigis, Hill3, and LSF, compared to those obtained using composite AL (0.38 vs. 0.62, 0.48 vs. 0.79, 0.50 vs. 0.90, 0.34 vs. 0.61, p < 0.001 for all formulas, respectively). On the contrary, the MedAE obtained by Kane with segmented AL was significantly worse compared to the one with composite AL (0.35 vs. 0.27, p = 0.03). Conclusion: In extremely high myopic eyes, the segmented AL improves the performance of SRK/T, Haigis, Hill3, and LSF formulas compared to the composite AL, while the segmented AL worsens the prediction accuracy of the Kane formula.