Chengju Shan

Dr. Chengju Shan


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2024 in Water
Verified
Journal Article
Open access
PDF file
CSChengju Shan
Chengju Shan
FZFuwei Zhao
Fuwei Zhao
YWYuejing Wang
Yuejing Wang
CYChenggang Yang
Chenggang Yang
FWFusen Wei
Fusen Wei
XZXueyang Zhou
Xueyang Zhou
Over the past 50 years, there have been significant changes in the runoff process in the Luanhe River basin, exacerbating the scarcity of water resources and their spatiotemporal variability. Therefore, conducting research on the characteristics, trends, and cycles of runoff changes in the Luanhe River basin is of great theoretical and practical significance. This study selected rainfall data from the hydrological stations in Weichang, Chengde, and Qinhuangdao in the Luanhe River basin, covering the period from 1985 to 2008, as well as runoff data from the Hanjiaying, Sandaohezi, and Chengde stations. Based on linear trend regression analysis, the Mann–Kendall rank correlation test, Spearman correlation test, Mann–Kendall method, and Mann–Whitney–Pettitt change point analysis method, this study analyzed the trends in water quantity changes and their change points in the Luanhe River basin. The results of the precipitation at the Weichang and Chengde stations show a non-significant rising trend, remaining relatively stable with slightly increases. Conversely, the precipitation of Qinhuangdao Station shows a decreasing trend over time, albeit non-significant. Considering the detailed diagnostic results from both the Mann–Kendall (M-K) and MWP methods, the change point for Weichang precipitation is identified as 2007, while for Chengde, it spans from 1999 to 2002, and for Qinhuangdao, it is around 1997. The trend of the runoff series of three stations shows a significant decreasing trend and strong significance, and the change point for the annual runoff at the Hanjiaying station and the Sandaohezi station is identified as 2006, and for the Chengde station, the primary change point is 2006, with a secondary change point around 2002. The findings of this research can provide scientific references for the rational development and utilization of regional water resources.

5 June 2023 in Energies
Verified
Journal Article
Open access
PDF file
JHJianyong Hu
Jianyong Hu
朝王朝昊 王
朝昊 王
CSChengju Shan
Chengju Shan
YGYunhui Guo
Yunhui Guo
The stable operation of a variable frequency pump is of great importance to the management of a water supply project. Analyzing the operation performance based on monitoring data is necessary for maintaining the stable operation of a variable frequency pump. Several sensors are installed at six monitoring points on the pump to collect signals including vibration velocity, vibration acceleration and vibration displacement. Monitoring signals are preprocessed by smoothing, adjusting waveform trend and filtering on the basis of Fast Fourier Transform (FFT). Then, the vibration features are extracted by power spectrum analysis and cepstrum analysis methods. According to the extracted features, the vibration law and actual operation performance of a variable frequency pump under different operating conditions are analyzed. Results indicate that the vibration amplitude of the pump varies sharply under the operating conditions of [15 Hz, 20 Hz] and [30 Hz, 35 Hz]. The operating condition of [0 Hz, 15 Hz] is the restricted operating area of the pump. The vibration and noise continue increasing under the operating conditions of [35 Hz, 50 Hz] and reach the maximum values at 50 Hz. Therefore, the optimal operating is within the range of [20 Hz, 30 Hz]. Finally, by analyzing the critical values of the operating conditions, the fault diagnosis and the evaluation of the operating status are conducted.