Avery Berman

Dr. Avery Berman

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in NeuroImage
Verified
Journal Article
Closed access
MMM. Ethan MacDonald
M. Ethan MacDonald
ABAvery Berman
Avery Berman
EMErin L. Mazerolle
Erin L. Mazerolle
RWRebecca Williams
Rebecca Williams
GPG. Bruce Pike
G. Bruce Pike

23 July 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ABAvery Berman
Avery Berman
WGWilliam A. Grissom
William A. Grissom
TWThomas Witzel
Thomas Witzel
SNShahin Nasr
Shahin Nasr
DPDaniel J. Park
Daniel J. Park
JPJonathan R. Polimeni
Jonathan R. Polimeni

2 December 2015 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
YMYuhan Ma
Yuhan Ma
ABAvery Berman
Avery Berman
BPBruce Pike
Bruce Pike

1 April 2018 in NeuroImage
Verified
Journal Article
Closed access
ABAvery Berman
Avery Berman
EMErin L. Mazerolle
Erin L. Mazerolle
MMM. Ethan MacDonald
M. Ethan MacDonald
NBNicholas Blockley
Nicholas Blockley
WLWen-Ming Luh
Wen-Ming Luh
GPG. Bruce Pike
G. Bruce Pike

14 January 2009 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
AJAndrew Jirasek
Andrew Jirasek
MHM Hilts
M Hilts
ABAvery Berman
Avery Berman
KMKimberley Mcauley
Kimberley Mcauley
A factor currently limiting the clinical utility of x-ray CT polymer gel dosimetry is the overall low dose sensitivity (and hence low dose resolution) of the system. Hence, active research remains in the investigation of polymer gel formulations with increased CT dose response. An ideal polymer gel dosimeter will exhibit a sensitive CT response which is linear over a suitable dose range, making clinical implementation reasonably straightforward. This study reports on the variations in rate and form of the CT dose response of irradiated polymer gels manufactured with glycerol, which is a co-solvent that permits dissolution of additional bisacrylamide above its water solubility limit (3% by weight). This study focuses on situations where the concentration of bisacrylamide is kept at or below its water solubility limit so that the influence of the co-solvent on the dose response can be explored separately from the effects of increased cross-linker concentration. CT imaging and Raman spectroscopy are used to construct dose-response curves for irradiated gels varying in (i) initial total monomer (%T) and (ii) initial co-solvent concentration. Results indicate that: (i) for a fixed glycerol concentration, gel response increases linearly with %T. Furthermore, the functional form of the dose response remains constant, in agreement with a previous model of polymer formation. (ii) Polymer gels with constant %T and increasing co-solvent concentrations also show enhanced CT response. In addition, the functional form of the response is altered in these gels as co-solvent concentration is increased. Raman data indicate that the fraction of bis-acrylamide incorporated into polymerization, as opposed to cyclization, increases as co-solvent concentration increases. The changes in functional form indicate varying polymer yields (per unit dose), akin to relative fractional monomer/cross-linker (i.e. %C) changes in earlier studies. These results are put into context of the model of polymer formation. The implications of these results on the clinical utility of polymer gels with co-solvent are highlighted.

1 June 2007 in Future Generation Computer Systems
Verified
Journal Article
Closed access
AAA. Agarwal
A. Agarwal
MAM. Ahmed
M. Ahmed
ABAvery Berman
Avery Berman
BCB.L. Caron
B.L. Caron
ACA. Charbonneau
A. Charbonneau
MYM. Yuen
M. Yuen